All MIBs › PROBE-MIB › currentUtilization
currentUtilization
Module: PROBE-MIB
OID (symbolic): PROBE-MIB::currentUtilization
OID (numeric): 1.3.6.1.4.1.11.2.3.7.6.1.5.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: NOTE: Because, this variable has been obsoleted by the currentUtilizationTable, it will be deprecated in a future firmware release. Applications should migrate to the new MIB variable as soon as possible.
The best estimate of the mean physical layer network utilization on the monitor's physical interface during the previous number of seconds defined by currentUtilizationPeriod. The units of this object are hundredths of a percent. Its value will normally be in the range (0..10000). A value of all 1's means that a full currentUtilizationPeriod has not passed since either monitor startup or the last time currentUtilizationPeriod was changed. On a multi-interface probe, this value applies only to interface index 1. Refer to currentUtilizationTable in this document for the current utilization value for the other interfaces on a multi- interface probe.
What is currentUtilization?
Deprecated single-interface utilization reading, superseded by the currentUtilizationTable; reports the mean physical-layer network utilization over the last currentUtilizationPeriod seconds, in hundredths of a percent (0-10000), with all-1s meaning a full period hasn't yet elapsed since startup or a period change.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.3.7.6.1.5.1.2 snmpwalk -v2c -c public <target> PROBE-MIB::currentUtilization
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.3.7.6.1.5.1.2.1 snmpget -v2c -c public <target> PROBE-MIB::currentUtilization.1
Start monitoring dedicated RMON/network probe appliances, vendor-implemented, may vary by manufacturer with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PROBE-MIB::currentUtilization OID value, configure state conditions and alerts, and monitor any dedicated RMON/network probe appliances, vendor-implemented, may vary by manufacturer from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3 | hpsystem | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3.7 | netElement | HP-BASE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.3.7.6 | lanprobe | PROBE-MIB |
| 1.3.6.1.4.1.11.2.3.7.6.1 | general | PROBE-MIB |
| 1.3.6.1.4.1.11.2.3.7.6.1.5 | rmonExtension | PROBE-MIB |
| 1.3.6.1.4.1.11.2.3.7.6.1.5.1 | statsExtension | PROBE-MIB |
| 1.3.6.1.4.1.11.2.3.7.6.1.5.1.2 | currentUtilization | PROBE-MIB |