PRIMEPOWER-XSCF-MIB :: scfRotationValue

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › PRIMEPOWER-XSCF-MIB › scfRotationValue

scfRotationValue

Module: PRIMEPOWER-XSCF-MIB

OID (symbolic): PRIMEPOWER-XSCF-MIB::scfRotationValue

OID (numeric): 1.3.6.1.4.1.211.1.15.2.1.4.3.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

What is scfRotationValue?

The rotation-speed reading for this sensor, in RPM (1 rpm units) — typically a fan speed — check scfRotationStatus first since an invalid reading here is meaningless.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.211.1.15.2.1.4.3.1.5
snmpwalk -v2c -c public <target> PRIMEPOWER-XSCF-MIB::scfRotationValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.211.1.15.2.1.4.3.1.5.1
snmpget -v2c -c public <target> PRIMEPOWER-XSCF-MIB::scfRotationValue.1

Start monitoring Fujitsu PRIMEPOWER server, XSCF service processor with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PRIMEPOWER-XSCF-MIB::scfRotationValue OID value, configure state conditions and alerts, and monitor any Fujitsu PRIMEPOWER server, XSCF service processor from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.211fujitsuAlert-Definition-Originator-MIB
1.3.6.1.4.1.211.1productCFAB-MIB
1.3.6.1.4.1.211.1.15solarisOPL-SP-MIB
Numeric OIDNameModule
1.3.6.1.4.1.211.1.15.2primepowerPRIMEPOWER-XSCF-MIB
1.3.6.1.4.1.211.1.15.2.1scfObjectsPRIMEPOWER-XSCF-MIB
1.3.6.1.4.1.211.1.15.2.1.4scfMonitorPRIMEPOWER-XSCF-MIB
1.3.6.1.4.1.211.1.15.2.1.4.3scfRotationTablePRIMEPOWER-XSCF-MIB
1.3.6.1.4.1.211.1.15.2.1.4.3.1scfRotationEntryPRIMEPOWER-XSCF-MIB
1.3.6.1.4.1.211.1.15.2.1.4.3.1.5scfRotationValuePRIMEPOWER-XSCF-MIB