All MIBs › PRESTICOM7-MIB › ifvceBroadcastDir
ifvceBroadcastDir
Module: PRESTICOM7-MIB
OID (symbolic): PRESTICOM7-MIB::ifvceBroadcastDir
OID (numeric): 1.3.6.1.4.1.727.7.2.18.2.1.36
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: When line activation is broadcast (Activation Type parameter set to BROADCAST), this parameter is used to specify whether the voice port will transmit(TX) or receive (RX) broadcast messages.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.727.7.2.18.2.1.36 snmpwalk -v2c -c public <target> PRESTICOM7-MIB::ifvceBroadcastDir
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.727.7.2.18.2.1.36.1 snmpget -v2c -c public <target> PRESTICOM7-MIB::ifvceBroadcastDir.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.727.7.2.18.2.1.36.1 i <value>
Start monitoring Legacy voice/data access equipment, enterprise OID 727 (Presticom) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PRESTICOM7-MIB::ifvceBroadcastDir OID value, configure state conditions and alerts, and monitor any Legacy voice/data access equipment, enterprise OID 727 (Presticom) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.727 | lucent | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7 | cleartrac7 | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7.2 | mgmt | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7.2.18 | ifvce | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7.2.18.2 | ifvceTable | CLEARTRAC7-MIB |
| 1.3.6.1.4.1.727.7.2.18.2.1 | ifvceEntry | CLEARTRAC7-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.727.7.2.18.2.1.36 | ifvceBroadcastDir | PRESTICOM7-MIB |