PIM-STD-MIB :: pimNeighborUpTime

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsPIM-STD-MIBpimNeighborUpTime

pimNeighborUpTime

Module: PIM-STD-MIB

OID (symbolic): PIM-STD-MIB::pimNeighborUpTime

OID (numeric): 1.3.6.1.2.1.157.1.2.1.6

Node type: OBJECT-TYPE

Type: TimeTicks

Access: read-only

Description: The time since this PIM neighbor (last) became a neighbor of the local router.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.157.1.2.1.6
snmpwalk -v2c -c public <target> PIM-STD-MIB::pimNeighborUpTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.157.1.2.1.6.1
snmpget -v2c -c public <target> PIM-STD-MIB::pimNeighborUpTime.1

Start monitoring vendor-neutral, standards-based MIB (PIM-SM/BIDIR-PIM/PIM-DM, RFC 5060) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PIM-STD-MIB::pimNeighborUpTime OID value, configure state conditions and alerts, and monitor any vendor-neutral, standards-based MIB (PIM-SM/BIDIR-PIM/PIM-DM, RFC 5060) from a single console.

How to Use in IPNetwork Monitor

Select a device implementing PIM-STD-MIB as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type pimNeighborUpTime into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports, in TimeTicks, how long this PIM neighbor relationship has been up. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a TimeTicks-type OID, Value bounds is the most useful condition here — trigger an alert if the uptime resets to a small value unexpectedly, which indicates the PIM adjacency to that neighbor was recently lost and re-established. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
Numeric OIDNameModule
1.3.6.1.2.1.157pimStdMIBPIM-STD-MIB
1.3.6.1.2.1.157.1pimPIM-STD-MIB
1.3.6.1.2.1.157.1.2pimNeighborTablePIM-STD-MIB
1.3.6.1.2.1.157.1.2.1pimNeighborEntryPIM-STD-MIB
1.3.6.1.2.1.157.1.2.1.6pimNeighborUpTimePIM-STD-MIB