All MIBs › PDN-REACHDSL-MIB › reachDSLPotsDetectionVoltage
reachDSLPotsDetectionVoltage
Module: PDN-REACHDSL-MIB
OID (symbolic): PDN-REACHDSL-MIB::reachDSLPotsDetectionVoltage
OID (numeric): 1.3.6.1.4.1.1795.2.24.2.6.20.1.5.1.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This object defines the configurable voltage used to detect the presence of POTS on the DSL line. The range is 0-74 volts. The default value is 3 volts.
Note: This object can be accessed only for ifIndex values that belong to a physical interface. i.e. ifType = adsl/reachDSL.
What is reachDSLPotsDetectionVoltage?
Sets the voltage threshold (0-74V, default 3V) used to detect whether a POTS (plain old telephone) signal is present on this DSL line. Adjust if POTS detection is unreliable at the default voltage due to line characteristics.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1795.2.24.2.6.20.1.5.1.1 snmpwalk -v2c -c public <target> PDN-REACHDSL-MIB::reachDSLPotsDetectionVoltage
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1795.2.24.2.6.20.1.5.1.1.1 snmpget -v2c -c public <target> PDN-REACHDSL-MIB::reachDSLPotsDetectionVoltage.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.1795.2.24.2.6.20.1.5.1.1.1 i <value>
Start monitoring Paradyne ReachDSL modem/CPE and central-office DSL equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PDN-REACHDSL-MIB::reachDSLPotsDetectionVoltage OID value, configure state conditions and alerts, and monitor any Paradyne ReachDSL modem/CPE and central-office DSL equipment from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1795 | pdyn | PDN-HEADER-MIB |
| 1.3.6.1.4.1.1795.2 | pdn_mgmt | PDN-HEADER-MIB |
| 1.3.6.1.4.1.1795.2.24 | paradyne | PDN-HEADER-MIB |
| 1.3.6.1.4.1.1795.2.24.2 | pdn_common | PDN-HEADER-MIB |
| 1.3.6.1.4.1.1795.2.24.2.6 | pdn_interfaces | PDN-HEADER-MIB |
| 1.3.6.1.4.1.1795.2.24.2.6.20 | pdnReachDSL | PDN-HEADER-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1795.2.24.2.6.20.1 | pdnReachDSLObjects | PDN-REACHDSL-MIB |
| 1.3.6.1.4.1.1795.2.24.2.6.20.1.5 | reachDSLLineTable | PDN-REACHDSL-MIB |
| 1.3.6.1.4.1.1795.2.24.2.6.20.1.5.1 | reachDSLLineEntry | PDN-REACHDSL-MIB |
| 1.3.6.1.4.1.1795.2.24.2.6.20.1.5.1.1 | reachDSLPotsDetectionVoltage | PDN-REACHDSL-MIB |