All MIBs › PDN-LINK-FAULT-MGMT-MIB › pdnLinkFailureSdBerThreshold
pdnLinkFailureSdBerThreshold
Module: PDN-LINK-FAULT-MGMT-MIB
OID (symbolic): PDN-LINK-FAULT-MGMT-MIB::pdnLinkFailureSdBerThreshold
OID (numeric): 1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.6
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: This object allows users to configure the threshold for the Signal Degrade Bit Error Rate (Sd).
The negated value of this number is used as the exponent of 10 for computing the threshold value for the Bit Error Rate (BER). For example, a value of 5 indicates a BER threshold of 10^-5.
What is pdnLinkFailureSdBerThreshold?
This read-write Integer32 (5-9), indexed per interface, sets the exponent used to compute the bit error rate threshold that defines a Signal Degraded condition, where the configured value n yields a BER threshold of 10^-n. Admins tune this to control how sensitive the Sd detection is; a value of 5 (10^-5) is more sensitive than a value of 9 (10^-9). For example, setting pdnLinkFailureSdBerThreshold to 6 means the link is considered degraded once its bit error rate reaches roughly 1 error per million bits (10^-6).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.6 snmpwalk -v2c -c public <target> PDN-LINK-FAULT-MGMT-MIB::pdnLinkFailureSdBerThreshold
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.6.1 snmpget -v2c -c public <target> PDN-LINK-FAULT-MGMT-MIB::pdnLinkFailureSdBerThreshold.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.6.1 i <value>
Start monitoring Paradyne access/transport equipment with protected primary/secondary links (Ethernet OAM link fault management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PDN-LINK-FAULT-MGMT-MIB::pdnLinkFailureSdBerThreshold OID value, configure state conditions and alerts, and monitor any Paradyne access/transport equipment with protected primary/secondary links (Ethernet OAM link fault management) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1795 | pdyn | PDN-HEADER-MIB |
| 1.3.6.1.4.1.1795.2 | pdn_mgmt | PDN-HEADER-MIB |
| 1.3.6.1.4.1.1795.2.24 | paradyne | PDN-HEADER-MIB |
| 1.3.6.1.4.1.1795.2.24.2 | pdn_common | PDN-HEADER-MIB |
| 1.3.6.1.4.1.1795.2.24.2.40 | pdnLinkFaultMgmt | PDN-HEADER-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1795.2.24.2.40.1 | pdnLinkFaultMgmtMIB | PDN-LINK-FAULT-MGMT-MIB |
| 1.3.6.1.4.1.1795.2.24.2.40.1.1 | pdnLinkFaultMgmtMIBObjects | PDN-LINK-FAULT-MGMT-MIB |
| 1.3.6.1.4.1.1795.2.24.2.40.1.1.3 | pdnLinkFailureConfigTable | PDN-LINK-FAULT-MGMT-MIB |
| 1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1 | pdnLinkFailureConfigEntry | PDN-LINK-FAULT-MGMT-MIB |
| 1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.6 | pdnLinkFailureSdBerThreshold | PDN-LINK-FAULT-MGMT-MIB |