All MIBs › PCI-HOTPLUG-MIB › siePciHotPlugSlotLogicalIdentifier
siePciHotPlugSlotLogicalIdentifier
Module: PCI-HOTPLUG-MIB
OID (symbolic): PCI-HOTPLUG-MIB::siePciHotPlugSlotLogicalIdentifier
OID (numeric): 1.3.6.1.4.1.231.2.10.2.2.6.2.2.1.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Logical Identifier to uniquely identify a Hot Plug slot; -1 if unknown.
What is siePciHotPlugSlotLogicalIdentifier?
This read-only integer uniquely identifies a given Hot Plug slot within the slot table and also serves as the table's index, returning -1 if unknown. Admins use it to correlate a specific row of slot status data (bus number, card state, LEDs) back to a single physical hot-plug slot. For example, walking the table and finding logical identifier 3 lets the admin match that row's card-present and card-state values to the third hot-plug slot.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.6.2.2.1.1 snmpwalk -v2c -c public <target> PCI-HOTPLUG-MIB::siePciHotPlugSlotLogicalIdentifier
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.6.2.2.1.1.1 snmpget -v2c -c public <target> PCI-HOTPLUG-MIB::siePciHotPlugSlotLogicalIdentifier.1
Start monitoring servers with PCI/PCI-X hot-plug backplanes with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PCI-HOTPLUG-MIB::siePciHotPlugSlotLogicalIdentifier OID value, configure state conditions and alerts, and monitor any servers with PCI/PCI-X hot-plug backplanes from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.231 | sni | AN-MIB |
| 1.3.6.1.4.1.231.2 | sniProductMibs | Application-Monitoring-MIB |
| 1.3.6.1.4.1.231.2.10 | sniExtensions | DESKTRAP-MIB |
| 1.3.6.1.4.1.231.2.10.2 | sniServerMgmt | FSC-SWITCH-MIB |
| 1.3.6.1.4.1.231.2.10.2.2 | sniCommon | FSC-SWITCH-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.231.2.10.2.2.6 | sieHotPlug | PCI-HOTPLUG-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.6.2 | siePciHotPlugSlot | PCI-HOTPLUG-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.6.2.2 | siePciHotPlugSlotTable | PCI-HOTPLUG-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.6.2.2.1 | siePciHotPlugSlotEntry | PCI-HOTPLUG-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.6.2.2.1.1 | siePciHotPlugSlotLogicalIdentifier | PCI-HOTPLUG-MIB |