All MIBs › PAD-OPT-MIB › cdx6500padpCfgTermControl
cdx6500padpCfgTermControl
Module: PAD-OPT-MIB
OID (symbolic): PAD-OPT-MIB::cdx6500padpCfgTermControl
OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.1.1.1.11
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-write
Description: Specify options for the attached device: NONE - no option specified. PASS - require password entry to use this PAD facility. LIM - limit X.28 access to CALL and CLR commands only. CUG - check closed user group; otherwise, CUG passes transparently. LCPY - allow local copying to this PAD port. 7BIT - use 7 data bits for character processing. NADD - prevent PAD port from receiving calling address and FAC service signals. X28 - automatically return from X.28 mode to PAD mode after sending the X.28 commands. CNUI - Centralized NUI verification. CUGOA - check closed user group but allow outgoing access; otherwise, CUG passes transparently. BMSG - show the PAD Bulletin/Banner Message even if the PAD Profile #6 is configured as 1 or 5. ADDR - does not show the calling address HENNIS - supports Hanil bank terminal. FRCB - connect to a French Cartes Bancaires terminal CUGIA - check closed user group but allow incoming access; otherwise, CUG passes transparently.\r\n\ NO-NULL - If port speed is below or equal to 1200, null characters won't be appended to LF. BCUG-ON- Subscription to Bilateral Closed User Group facility enabled. BCUGOA - Subscription to Bilateral Closed User Group with Outgoing Access facility enabled. BCUG-OFF-Subscription to Bilateral Closed User Group related facilities disabled. BCUG-ON, BCUGOA and BCUG-OFF options are mutually exclusive. Any combination of above specified by summing (e.g. PASS+LIM).
What is cdx6500padpCfgTermControl?
A combinable set of codes controlling attached-terminal behavior, such as PASS (require a password), LIM (restrict X.28 commands to CALL/CLR only), or CUG (enforce closed-user-group checks); an admin sums the codes for whatever combination of restrictions the port needs.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.1.1.11 snmpwalk -v2c -c public <target> PAD-OPT-MIB::cdx6500padpCfgTermControl
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.1.1.11.1 snmpget -v2c -c public <target> PAD-OPT-MIB::cdx6500padpCfgTermControl.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.449.2.1.2.1.1.1.1.11.1 s <value>
Start monitoring CDX6500-series X.25/PAD access device, legacy packet-switching access equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PAD-OPT-MIB::cdx6500padpCfgTermControl OID value, configure state conditions and alerts, and monitor any CDX6500-series X.25/PAD access device, legacy packet-switching access equipment from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.449 | codex | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2 | cdxProductSpecific | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1 | cdx6500 | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2 | cdx6500Configuration | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1 | cdx6500CfgProtocolGroup | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1 | cdx6500PCTPortProtocolGroup | ALC-OPT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.449.2.1.2.1.1.1 | cdx6500PPCTPadPortTable | PAD-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1 | cdx6500PPCTPadPortEntry | PAD-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.1.1.11 | cdx6500padpCfgTermControl | PAD-OPT-MIB |