-- Version 2.15.1.1, modified 2001-05-31 17:28:13-04 PAD-OPT-MIB DEFINITIONS ::= BEGIN IMPORTS Counter, enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- Codex MIB Group definitions codex OBJECT IDENTIFIER ::= { enterprises 449 } cdxProductSpecific OBJECT IDENTIFIER ::= { codex 2 } cdx6500 OBJECT IDENTIFIER ::= { cdxProductSpecific 1 } cdx6500Configuration OBJECT IDENTIFIER ::= { cdx6500 2 } cdx6500CfgProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 1 } cdx6500CfgGeneralGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 2 } cdx6500PCTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 1 } cdx6500Statistics OBJECT IDENTIFIER ::= { cdx6500 3 } cdx6500StatProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 1 } cdx6500PSTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 1 } cdx6500Controls OBJECT IDENTIFIER ::= { cdx6500 4 } -- Textual Conventions Counter16 ::= INTEGER (0..65535) DisplayString ::= OCTET STRING -- PAD Port Objects -- The Pad Port Configuration Table -- This table contains Configuration paramaters -- for the Pad Port table. cdx6500PPCTPadPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPCTPadPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the configuration parameters relevant to the Pad Port table. " ::= { cdx6500PCTPortProtocolGroup 1 } cdx6500PPCTPadPortEntry OBJECT-TYPE SYNTAX Cdx6500PPCTPadPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Pad Port configuration parameters." INDEX { cdx6500padpCfgPortNum } ::= { cdx6500PPCTPadPortTable 1 } Cdx6500PPCTPadPortEntry ::= SEQUENCE { cdx6500padpCfgPortNum INTEGER, cdx6500padpCfgConnectionType INTEGER, cdx6500padpCfgPortControl DisplayString, cdx6500padpCfgPortSpeed INTEGER, cdx6500padpCfgAutoBaudSeq INTEGER, cdx6500padpCfgDataBits INTEGER, cdx6500padpCfgParity INTEGER, cdx6500padpCfgStopBits INTEGER, cdx6500padpCfgProfileName DisplayString, cdx6500padpCfgCallControl DisplayString, cdx6500padpCfgTermControl DisplayString, cdx6500padpCfgPadPromptNum INTEGER, cdx6500padpCfgRemoteParamNum INTEGER, cdx6500padpCfgAutoCallMnem DisplayString, cdx6500padpCfgAutoCallTimeout INTEGER, cdx6500padpCfgMaxAutoCall INTEGER, cdx6500padpCfgSubAddress DisplayString, cdx6500padpCfgGroupSubaddress DisplayString, cdx6500padpCfgCugMembership DisplayString, cdx6500padpCfgBillingRecord INTEGER, cdx6500padpCfgInviteToClr INTEGER, cdx6500padpCfgCallAcceptTime INTEGER, cdx6500padpCfgProtectionLevel INTEGER, cdx6500padpCfgReconnectTimeout INTEGER, cdx6500padpCfgReconnectTries INTEGER, cdx6500padpCfgMaxRcvBufLength INTEGER, cdx6500padpCfgCommandLanguage INTEGER, cdx6500padpCfgNUIFacilityFormat INTEGER, cdx6500padpCfgNUIVerifyTimer INTEGER, cdx6500padpCfgMaxNUIViolations INTEGER, cdx6500padpCfgActionTypeNUIV INTEGER, cdx6500padpCfgCalledDTEAddress DisplayString, cdx6500padpCfgCallingDTEIdent DisplayString, cdx6500padpCfgCallingDTEPasswd DisplayString, cdx6500padpCfgX28ResetService DisplayString, cdx6500padpCfgX28ClearService DisplayString, cdx6500padpCfgMAXMNEMFailures INTEGER, cdx6500padpCfgActionTypeMNEMFail INTEGER, cdx6500padpCfgActiveLineMessage DisplayString, cdx6500padpCfgDelayActiveLine INTEGER, cdx6500padpCfgInterCharTimer INTEGER, cdx6500padpCfgElectricalInterfaceType INTEGER, cdx6500padpCfgV24ElectricalInterfaceOption INTEGER, cdx6500padpCfgHighSpeedElectricalInterfaceOption INTEGER } cdx6500padpCfgPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the number of the port that you are configuring. This number also serves as an entry number for the port you are about to configure." ::= { cdx6500PPCTPadPortEntry 1 } cdx6500padpCfgConnectionType OBJECT-TYPE SYNTAX INTEGER { simp (0), dtr (1), dtrd (2), emri (3), emdc (4), dimo (5), dimoa (6), dimob (7), dtrp (8), emdcio (21), newvalSimp (50) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the control signal handshake and clocking required for a connection to be made to this port: simp - simple, no control signals required. dtr - dedicated, require the data terminal ready signal (DTR). dtrd - same as DTR, except data set ready (DSR) drops between calls. dtrp - same as DTR, except DSR/DCD/CTS are held low in the idle state. dimo - port handshakes with attached dial modem. dimoa - same as DIMO except DSR never raised on incoming call from modem. dimob - same as DIMO except DSR follows DTR on incoming call from modem. emri - port emulates a dial modem with ring indicator (RI). emdc - port emulates a dial modem with data carrier detect (DCD). emdcio - port emulates a dial modem with DCD for incoming and outgoing calls. newvalSimp - same functionality as 'simp', new enumeration added for RFc1155 compatibility." ::= { cdx6500PPCTPadPortEntry 2 } cdx6500padpCfgPortControl OBJECT-TYPE SYNTAX DisplayString (SIZE(2..4)) ACCESS read-write STATUS mandatory DESCRIPTION "Specify any of the following port control options: NONE - no option specified. MB - raise Pin 22 when the port becomes disabled." ::= { cdx6500PPCTPadPortEntry 3 } cdx6500padpCfgPortSpeed OBJECT-TYPE SYNTAX INTEGER { speed110 (0), speed134 (1), speed300 (2), speed1200 (3), speed600 (4), speed75 (5), speed150 (6), speed1800 (7), speed200 (8), speed100 (9), speed50 (10), speed75to1200 (11), speed2400 (12), speed4800 (13), speed9600 (14), speed19200 (15), speed38400 (16), speed115200 (17), speed57600 (18), speed14400 (19), speed28800 (20), speed12000 (21), speed16800 (22), speed21600 (23), speed24000 (24), speed26400 (25), speed33400 (26), speed7200 (98), speedAuto (99), newvalSpeed110 (50) } ACCESS read-write STATUS mandatory DESCRIPTION "This is the speed of the port in bits per second (baud rate). newvalSpeed110 : same as 'speed110', new enumeration added for RFC1155 compliance." ::= { cdx6500PPCTPadPortEntry 4 } cdx6500padpCfgAutoBaudSeq OBJECT-TYPE SYNTAX INTEGER { crOnly (0), crDotCr (1), tymnet (2), telenet (3), dotDotCr (4), spacePCr (5), newvalCrOnly (50) } ACCESS read-write STATUS mandatory DESCRIPTION "This is the type of sequence used for autospeed detection on an autospeed port. crOnly - autospeed on crDotCr - autospeed on . tymnet - autospeed on a telenet - autospeed on for 1200 baud or lower autospeed on @ for 2400 baud or higher dotDotCr - autospeed on two or more dots followed by spacePCr - autospeed on P newvalCrOnly - same functionality as 'crOnly', new enumeration added for RFC1155 compatibility." ::= { cdx6500PPCTPadPortEntry 5 } cdx6500padpCfgDataBits OBJECT-TYPE SYNTAX INTEGER (5..8) ACCESS read-write STATUS mandatory DESCRIPTION "This is the number of data bits per character the PAD port expects when it transmits and receives data from the attached device." ::= { cdx6500PPCTPadPortEntry 6 } cdx6500padpCfgParity OBJECT-TYPE SYNTAX INTEGER { none (0), space (1), mark (2), even (3), odd (4), auto (5), autoA (6), newvalNone (50) } ACCESS read-write STATUS mandatory DESCRIPTION "This is the parity the PAD port generates and expects when it transmits and receives data from the attached device. none - no parity space - Space Parity mark - Mark Parity even - Even Parity odd - Odd Parity auto - Auto Parity ( 7 odd / 7 even / 7 ignore ) autoA - Auto Parity ( 7 odd / 7 even / 8 none ). newvalNone - same functionality as 'none', new enumeration added for RFC1155 compatibility." ::= { cdx6500PPCTPadPortEntry 7 } cdx6500padpCfgStopBits OBJECT-TYPE SYNTAX INTEGER { stopBit1 (0), stopBit1p5 (1), stopBit2 (2), newvalStopBit1 (50) } ACCESS read-write STATUS mandatory DESCRIPTION "This is the number of stop bits that the PAD port generates when it transmits data to the attached device. This parameter has no effect on data that is received from the attached device. stopBit1 - 1 Stop Bit. stopBit1p5 - 1.5 Stop Bits. stopBit2 - 2 Stop Bits. newvalStopBit1 - same functionality as 'stopBit1', new enumeration added for RFC1155 compatibility." ::= { cdx6500PPCTPadPortEntry 8 } cdx6500padpCfgProfileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the name of the PAD profile table to be used by this PAD port." ::= { cdx6500PPCTPadPortEntry 9 } cdx6500padpCfgCallControl OBJECT-TYPE SYNTAX DisplayString (SIZE(4..40)) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter allows call control to be used as follows: NONE - no option specified AUTO - automatic calling AUTC - automatic calling when carriage return received PCUD - pass call user data to user profiled for no service signals IBAR - bar calls inbound from PAD user OBAR - bar calls outbound to PAD user MNEM - allow mnemonic calls only EMNEM - allow extended mnemonic call (without DOT) Any combination of above specified by summing (e.g. AUTO+IBAR+. . .) TMNEM - Call Mnemonic (max 16 alphanumeric characters) which is not resolved in the local node. This option cannot be summed with any of the above." ::= { cdx6500PPCTPadPortEntry 10 } cdx6500padpCfgTermControl OBJECT-TYPE SYNTAX DisplayString (SIZE(3..60)) ACCESS read-write STATUS mandatory DESCRIPTION "Specify options for the attached device: NONE - no option specified. PASS - require password entry to use this PAD facility. LIM - limit X.28 access to CALL and CLR commands only. CUG - check closed user group; otherwise, CUG passes transparently. LCPY - allow local copying to this PAD port. 7BIT - use 7 data bits for character processing. NADD - prevent PAD port from receiving calling address and FAC service signals. X28 - automatically return from X.28 mode to PAD mode after sending the X.28 commands. CNUI - Centralized NUI verification. CUGOA - check closed user group but allow outgoing access; otherwise, CUG passes transparently. BMSG - show the PAD Bulletin/Banner Message even if the PAD Profile #6 is configured as 1 or 5. ADDR - does not show the calling address HENNIS - supports Hanil bank terminal. FRCB - connect to a French Cartes Bancaires terminal CUGIA - check closed user group but allow incoming access; otherwise, CUG passes transparently.\r\n\ NO-NULL - If port speed is below or equal to 1200, null characters won't be appended to LF. BCUG-ON- Subscription to Bilateral Closed User Group facility enabled. BCUGOA - Subscription to Bilateral Closed User Group with Outgoing Access facility enabled. BCUG-OFF-Subscription to Bilateral Closed User Group related facilities disabled. BCUG-ON, BCUGOA and BCUG-OFF options are mutually exclusive. Any combination of above specified by summing (e.g. PASS+LIM)." ::= { cdx6500PPCTPadPortEntry 11 } cdx6500padpCfgPadPromptNum OBJECT-TYPE SYNTAX INTEGER (0..8) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies which entry in the PAD Prompt Table is used as a PAD prompt." ::= { cdx6500PPCTPadPortEntry 12 } cdx6500padpCfgRemoteParamNum OBJECT-TYPE SYNTAX INTEGER (0..6) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies which entry in the Remote PAD Parameters Table is sent to a remote PAD to update its X.3 characteristics when it connects to this port: 0 - no remote PAD update is performed." ::= { cdx6500PPCTPadPortEntry 13 } cdx6500padpCfgAutoCallMnem OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) ACCESS read-write STATUS mandatory DESCRIPTION "This mnemonic name is used if this port is configured for auto-calling." ::= { cdx6500PPCTPadPortEntry 14 } cdx6500padpCfgAutoCallTimeout OBJECT-TYPE SYNTAX INTEGER (5..255) ACCESS read-write STATUS mandatory DESCRIPTION "This is the time interval in seconds between call attempts when auto-calling." ::= { cdx6500PPCTPadPortEntry 15 } cdx6500padpCfgMaxAutoCall OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter is used to specify the number of times that the PAD port will attempt to call, when auto-calling is enabled. A value of zero, will allow unlimited attempts." ::= { cdx6500PPCTPadPortEntry 16 } cdx6500padpCfgSubAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..3)) ACCESS read-write STATUS mandatory DESCRIPTION "Calls addressed to this node and with this subaddress will be routed to this port." ::= { cdx6500PPCTPadPortEntry 17 } cdx6500padpCfgGroupSubaddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..3)) ACCESS read-only STATUS mandatory DESCRIPTION "The group subaddress is shared by one or more ports. Calls addressed to this node and with this subaddress will be routed to a port within the group." ::= { cdx6500PPCTPadPortEntry 18 } cdx6500padpCfgCugMembership OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) ACCESS read-write STATUS mandatory DESCRIPTION "The port may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number (except --) and separated by a comma. ( e.g. 12,34,56,09,02,03 ). -- - No CUG Membership 00-99 - CUG Membership" ::= { cdx6500PPCTPadPortEntry 19 } cdx6500padpCfgBillingRecord OBJECT-TYPE SYNTAX INTEGER { off (0), on (1), newvalOff (50) } ACCESS read-write STATUS mandatory DESCRIPTION "This controls whether billing (accounting) records will be created for calls on this port. newvalOff : same functionality as 'off', new enumeration added for RFC1155 compatibility." ::= { cdx6500PPCTPadPortEntry 20 } cdx6500padpCfgInviteToClr OBJECT-TYPE SYNTAX INTEGER { none (0), clrwo (1), clrwd (2), newvalNone (50) } ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the handling of Invitation to Clear packet when received. none - Do nothing. clrwo - Clear Call without performing a EIA disconnect. clrwd - Clear Call and perform a EIA disconnect. newvalNone - same functionality as 'none', new enumeration added for RFC1155 compatibility." ::= { cdx6500PPCTPadPortEntry 21 } cdx6500padpCfgCallAcceptTime OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the time (in seconds) that the user has to make a successful call, after a call has been cleared, before being automatically disconnected. A maximum of three call attempts are permitted when the Call Accept Timer is enabled. 1-255 - Call Accept Timeout (in seconds) 0 - Disables the Call Accept Timer." ::= { cdx6500PPCTPadPortEntry 22 } cdx6500padpCfgProtectionLevel OBJECT-TYPE SYNTAX INTEGER { none (0), cpOnly (1), fullDcp (2), newvalNone (50) } ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the level of data or connection protection which will be applied to calls to or from this port. The actual level for a call will be negotiated to the lesser of this level and the level configured for the other end of the call. none - No protection cpOnly - Connection protection only fullDcp - Full data and connection protection. newvalNone - same functionality as 'none', new enumeration added for RFC1155 compatibility." ::= { cdx6500PPCTPadPortEntry 23 } cdx6500padpCfgReconnectTimeout OBJECT-TYPE SYNTAX INTEGER (1..128) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the number of seconds that DCP on the originating side will wait between reconnection attempts." ::= { cdx6500PPCTPadPortEntry 24 } cdx6500padpCfgReconnectTries OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the number of times that DCP on the originating side will attempt to reconnect before clearing the call. If 0 is entered, it will not attempt to reconnect." ::= { cdx6500PPCTPadPortEntry 25 } cdx6500padpCfgMaxRcvBufLength OBJECT-TYPE SYNTAX INTEGER (1..128) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the number of characters received by the driver before forwarding the packet. This parameter is configurable only for PAD ports of CPU+ cards. 1 - 128 : Value stored in MRBLR." ::= { cdx6500PPCTPadPortEntry 26 } cdx6500padpCfgCommandLanguage OBJECT-TYPE SYNTAX INTEGER { ccitt (1), dpn (2), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the language for PAD commands. ccitt : X.28 CCITT. dpn : DPN ITI. nc : Not configured." ::= { cdx6500PPCTPadPortEntry 27 } cdx6500padpCfgNUIFacilityFormat OBJECT-TYPE SYNTAX INTEGER { odpn (2), ndpn (3), dpn1992 (4), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies the format of the NUI facility field. odpn : Specifies the old DPN format. ndpn : Specifies the new DPN format. dpn1992 : 1992 NUI format. nc : Not configured." ::= { cdx6500PPCTPadPortEntry 28 } cdx6500padpCfgNUIVerifyTimer OBJECT-TYPE SYNTAX INTEGER (5..180) ACCESS read-write STATUS mandatory DESCRIPTION "Specify the NUI verification timer in seconds. The call is cleared when the timer expires." ::= { cdx6500PPCTPadPortEntry 29 } cdx6500padpCfgMaxNUIViolations OBJECT-TYPE SYNTAX INTEGER (0..10) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of successive NUI verification failures that can be tolerated when making verification attempts through a pad port." ::= { cdx6500PPCTPadPortEntry 30 } cdx6500padpCfgActionTypeNUIV OBJECT-TYPE SYNTAX INTEGER { none (1), degr (2), lock (3), disc (4), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the course of action to be taken if the NUI violations exceed the configured threshold count. This parameter is effective only if the Port Control parameter is set to CNUI. none : No action is taken . disc : Port is disconnected. degr : Port is busied-out for one minute then re-enabled. lock : Port is disabled. Operator intervention is required to enable the port. nc : Not configured." ::= { cdx6500PPCTPadPortEntry 31 } cdx6500padpCfgCalledDTEAddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "Called DTE Address for packets with Call Mnemonic." ::= { cdx6500PPCTPadPortEntry 32 } cdx6500padpCfgCallingDTEIdent OBJECT-TYPE SYNTAX DisplayString (SIZE(0..7)) ACCESS read-write STATUS mandatory DESCRIPTION "Calling DTE Identifier for packets with Call Mnemonic." ::= { cdx6500PPCTPadPortEntry 33 } cdx6500padpCfgCallingDTEPasswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..7)) ACCESS read-write STATUS mandatory DESCRIPTION "Calling DTE Password for packets with Call Mnemonic." ::= { cdx6500PPCTPadPortEntry 34 } cdx6500padpCfgX28ResetService OBJECT-TYPE SYNTAX DisplayString (SIZE(0..7)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the name of the X.28 Reset Service Signals table to be used by this PAD port." ::= { cdx6500PPCTPadPortEntry 35 } cdx6500padpCfgX28ClearService OBJECT-TYPE SYNTAX DisplayString (SIZE(0..7)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the name of the X.28 Clear Service Signals table to be used by this PAD port." ::= { cdx6500PPCTPadPortEntry 36 } cdx6500padpCfgMAXMNEMFailures OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of successive Mnemonic Call failures that can be tolerated when making a call to the remote using the mnemonic. This parameter is effective only if the Port Control parameter is set to MNEM." ::= { cdx6500PPCTPadPortEntry 37 } cdx6500padpCfgActionTypeMNEMFail OBJECT-TYPE SYNTAX INTEGER { none (1), degr (2), lock (3), disc (4), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the course of action to be taken if the Mnemonic exceed the configured threshold count. This parameter is effective only if the Port Control parameter is set to MNEM. none : No action is taken disc : Port is disconnected. degr : Port is busied-out for one minute then it is re-enabled. lock : Port is disabled. Operator intervention is required to enable the port. nc : Not configured." ::= { cdx6500PPCTPadPortEntry 38 } cdx6500padpCfgActiveLineMessage OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "The message to be printed when the line becomes active (DTR goes high)." ::= { cdx6500PPCTPadPortEntry 39 } cdx6500padpCfgDelayActiveLine OBJECT-TYPE SYNTAX INTEGER (1..5) ACCESS read-write STATUS mandatory DESCRIPTION "When the line becomes active (DTR goes high), Active line message is sent after configured time. This delay is in seconds." ::= { cdx6500PPCTPadPortEntry 40 } cdx6500padpCfgInterCharTimer OBJECT-TYPE SYNTAX INTEGER (0..5) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum time period allowed between received characters in a frame. Specified in 50ms increments (i.e. 5 means 250ms)." ::= { cdx6500PPCTPadPortEntry 41 } cdx6500padpCfgElectricalInterfaceType OBJECT-TYPE SYNTAX INTEGER { v24 (1), v35 (2), v36 (3), x21 (4), none (5) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled" ::= { cdx6500PPCTPadPortEntry 42 } cdx6500padpCfgV24ElectricalInterfaceOption OBJECT-TYPE SYNTAX INTEGER { ri (1), tm (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal" ::= { cdx6500PPCTPadPortEntry 43 } cdx6500padpCfgHighSpeedElectricalInterfaceOption OBJECT-TYPE SYNTAX INTEGER { none (1), xover (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable" ::= { cdx6500PPCTPadPortEntry 44 } -- The Pad Port Statistics Table cdx6500PPSTPadPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPSTPadPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the statistics parameters relevant to the Pad Port table." ::= { cdx6500PSTPortProtocolGroup 1 } cdx6500PPSTPadPortEntry OBJECT-TYPE SYNTAX Cdx6500PPSTPadPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Pad Port statistics parameters." INDEX { cdx6500padpStatPortNum } ::= { cdx6500PPSTPadPortTable 1 } Cdx6500PPSTPadPortEntry ::= SEQUENCE { cdx6500padpStatPortNum INTEGER, cdx6500padpStatPortStatus INTEGER, cdx6500padpStatUtilizationIn INTEGER, cdx6500padpStatUtilizationOut INTEGER, cdx6500padpStatPortSpeed INTEGER, cdx6500padpStatCharInTotal Counter, cdx6500padpStatCharOutTotal Counter, cdx6500padpStatCharsInPerSec INTEGER, cdx6500padpStatCharsOutPerSec INTEGER, cdx6500padpStatPktInTotal Counter, cdx6500padpStatPktOutTotal Counter, cdx6500padpStatPktsInPerSec INTEGER, cdx6500padpStatPktsOutPerSec INTEGER, cdx6500padpStatPktsQueued INTEGER, cdx6500padpStatOverrunErrors Counter16, cdx6500padpStatParityErrors Counter16, cdx6500padpStatFramingErrors Counter16, cdx6500padpStatCurrentStatus DisplayString, cdx6500padpStatPortState INTEGER } cdx6500padpStatPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the port." ::= { cdx6500PPSTPadPortEntry 1 } cdx6500padpStatPortStatus OBJECT-TYPE SYNTAX INTEGER { disabled (0), busyout (2), up (3), newvalDisabled (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of the port: up - port is up and running. busyout - port has been busied out. disabled - port has been disabled. newvalDisabled : same functionality 'disabled', new new enumeration added RFC1155 compatibility." ::= { cdx6500PPSTPadPortEntry 2 } cdx6500padpStatUtilizationIn OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Percentage of port bandwidth in use." ::= { cdx6500PPSTPadPortEntry 3 } cdx6500padpStatUtilizationOut OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Percentage of port bandwidth in use." ::= { cdx6500PPSTPadPortEntry 4 } cdx6500padpStatPortSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The configured port speed." ::= { cdx6500PPSTPadPortEntry 5 } cdx6500padpStatCharInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the characters being received over the port." ::= { cdx6500PPSTPadPortEntry 6 } cdx6500padpStatCharOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the characters being sent over the port." ::= { cdx6500PPSTPadPortEntry 7 } cdx6500padpStatCharsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the characters being received over the port." ::= { cdx6500PPSTPadPortEntry 8 } cdx6500padpStatCharsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the characters being sent over the port." ::= { cdx6500PPSTPadPortEntry 9 } cdx6500padpStatPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the packets being sent over the port." ::= { cdx6500PPSTPadPortEntry 10 } cdx6500padpStatPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the packets being sent over the port." ::= { cdx6500PPSTPadPortEntry 11 } cdx6500padpStatPktsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the packets being sent over the port." ::= { cdx6500PPSTPadPortEntry 12 } cdx6500padpStatPktsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Summary of the packets being sent over the port." ::= { cdx6500PPSTPadPortEntry 13 } cdx6500padpStatPktsQueued OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets queued for output." ::= { cdx6500PPSTPadPortEntry 14} cdx6500padpStatOverrunErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Number of Overrun errors since the last reset." ::= { cdx6500PPSTPadPortEntry 15 } cdx6500padpStatParityErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Number of Parity errors since the last reset." ::= { cdx6500PPSTPadPortEntry 16 } cdx6500padpStatFramingErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Number of Framing errors since the last reset." ::= { cdx6500PPSTPadPortEntry 17 } cdx6500padpStatCurrentStatus OBJECT-TYPE SYNTAX DisplayString (SIZE(6..10)) ACCESS read-only STATUS mandatory DESCRIPTION "Status of the call on the specific port (Disconnect, Calling, Called, Clearing, Connected, Local Copy)" ::= { cdx6500PPSTPadPortEntry 18 } cdx6500padpStatPortState OBJECT-TYPE SYNTAX INTEGER { pad (0), x28 (1), account (3), password (5), newvalPad (50), na (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Current port state: x28 : The port is in Command mode. pad : The port is in Data mode. account : The port is waiting for the account name. password : The port is waiting for the password. newvalPad: same functionality as 'pad', new enumeration added for RFC1155 compatibility. na : Value not available." ::= { cdx6500PPSTPadPortEntry 19 } -- The Pad Prompt Configuration Table cdx6500CfgPadPromptTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500CfgPadPromptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the configuration parameters relevant to the PAD Prompt table. " ::= { cdx6500CfgGeneralGroup 4 } cdx6500CfgPadPromptEntry OBJECT-TYPE SYNTAX Cdx6500CfgPadPromptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Pad Prompt table parameters" INDEX { cdx6500padpromptEntryNum } ::= { cdx6500CfgPadPromptTable 1 } Cdx6500CfgPadPromptEntry ::= SEQUENCE { cdx6500padpromptEntryNum INTEGER, cdx6500padpromptPromptText DisplayString } cdx6500padpromptEntryNum OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "This is not a configuration parameter. Instead, it identifies the particular PAD Prompt Table entry being configured by the other parameter in the record." ::= { cdx6500CfgPadPromptEntry 1 } cdx6500padpromptPromptText OBJECT-TYPE SYNTAX DisplayString (SIZE(0..1024)) ACCESS read-only STATUS mandatory DESCRIPTION "Enter PAD prompt as an ASCII character string, terminated by a carriage return. Use line feed (^j) to generate a new line. The prompt can have up to 1023 characters. " ::= { cdx6500CfgPadPromptEntry 2 } -- The Pad Profile Configuration Table cdx6500CfgPadProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500CfgPadProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the configuration parameters relevant to the Pad Profile table. " ::= { cdx6500CfgGeneralGroup 8 } cdx6500CfgPadProfileEntry OBJECT-TYPE SYNTAX Cdx6500CfgPadProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Pad Profile configuration parameters" INDEX { cdx6500padprofProfileNum } ::= { cdx6500CfgPadProfileTable 1 } Cdx6500CfgPadProfileEntry ::= SEQUENCE { cdx6500padprofProfileNum INTEGER, cdx6500padprofProfileName DisplayString, cdx6500padprofPar1 INTEGER, cdx6500padprofPar2 INTEGER, cdx6500padprofPar3 DisplayString, cdx6500padprofPar4 INTEGER, cdx6500padprofPar5 INTEGER, cdx6500padprofPar6 INTEGER, cdx6500padprofPar7 INTEGER, cdx6500padprofPar9 INTEGER, cdx6500padprofPar10 INTEGER, cdx6500padprofPar12 INTEGER, cdx6500padprofPar13 DisplayString, cdx6500padprofPar14 INTEGER, cdx6500padprofPar15 INTEGER, cdx6500padprofPar16 INTEGER, cdx6500padprofPar17 INTEGER, cdx6500padprofPar18 INTEGER, cdx6500padprofPar19 INTEGER, cdx6500padprofPar20 DisplayString, cdx6500padprofPar21 INTEGER, cdx6500padprofPar22 INTEGER, cdx6500padprofPar100 INTEGER, cdx6500padprofPar101 INTEGER, cdx6500padprofPar102 INTEGER, cdx6500padprofPar103 INTEGER, cdx6500padprofPar104 INTEGER, cdx6500padprofPar105 DisplayString, cdx6500padprofPar106 INTEGER, cdx6500padprofPar107 INTEGER, cdx6500padprofPar108 INTEGER, cdx6500padprofPar109 INTEGER, cdx6500padprofPar110 INTEGER, cdx6500padprofPar111 INTEGER, cdx6500padprofPar112 INTEGER, cdx6500padprofPar113 INTEGER, cdx6500padprofPar114 INTEGER, cdx6500padprofPar115 INTEGER, cdx6500padprofPar116 INTEGER, cdx6500padprofPar117 INTEGER, cdx6500padprofPar118 INTEGER, cdx6500padprofPar119 INTEGER } cdx6500padprofProfileNum OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "This is not a configuration parameter. Instead, it identifies the particular PAD Profile Table entry being configured by the other parameters in the record." ::= { cdx6500CfgPadProfileEntry 1 } cdx6500padprofProfileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Reference name for this PAD profile. Individual parameter prompt messages are prefixed with X.3 parameter number. Numbers greater than 100 indicate proprietary extensions." ::= { cdx6500CfgPadProfileEntry 2 } cdx6500padprofPar1 OBJECT-TYPE SYNTAX INTEGER (0..126) ACCESS read-only STATUS mandatory DESCRIPTION "#1, enables PAD recall to command mode during a call: 0 - PAD recall disabled 1 - PAD recall character = DLE = <^P> 32-126 - decimal value of character used for PAD recall" ::= { cdx6500CfgPadProfileEntry 3 } cdx6500padprofPar2 OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "#2, controls echo: 0 - echo disabled 1 - echo enabled." ::= { cdx6500CfgPadProfileEntry 4 } cdx6500padprofPar3 OBJECT-TYPE SYNTAX DisplayString (SIZE(1..18)) ACCESS read-only STATUS mandatory DESCRIPTION "#3, selects the ASCII characters used for data forwarding: 0 - no data forwarding characters 1 - A-Z, a-z, 0-9 2 - CR 4 - ESC, BEL,ENQ, ACK 8 - DEL, CAN, DC2 16 - EOT, ETX 32 - HT, LF, VT, FF 64 - all characters in columns 0 and 1 of the ASCII table not mentioned above XXX - any combination of the above values." ::= { cdx6500CfgPadProfileEntry 5 } cdx6500padprofPar4 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "#4, selects forwarding idle timer delay: 0 - idle timer disabled 1 to 255 - value of idle timer in 1/20 seconds." ::= { cdx6500CfgPadProfileEntry 6 } cdx6500padprofPar5 OBJECT-TYPE SYNTAX INTEGER (0..2) ACCESS read-only STATUS mandatory DESCRIPTION "#5, specifies whether the attached terminal is flow controlled (restrained from sending data) by the PAD port sending the XON, XOFF characters. Also called Data Restraint Inbound (DRI) using in-band control: 0 - no control with XON, XOFF 1 - control inbound data from device 2 - control inbound data and PAD commands from device For DRI control using V.24 connector control signals (CTS and pin 14), use parameter #105." ::= { cdx6500CfgPadProfileEntry 7 } cdx6500padprofPar6 OBJECT-TYPE SYNTAX INTEGER (0..13) ACCESS read-only STATUS mandatory DESCRIPTION "#6, controls PAD service signal messages to the attached device: 0 - no service signal is sent 1 - service signals, other than the prompt, are sent 4 - prompt service signal is sent 5 - all service signals are sent 9 - extended format service signals, other than prompt, are sent 12 - extended format prompt service signal is sent 13 - all service signals are sent in extended format." ::= { cdx6500CfgPadProfileEntry 8 } cdx6500padprofPar7 OBJECT-TYPE SYNTAX INTEGER (0..21) ACCESS read-only STATUS mandatory DESCRIPTION "#7, selects the PAD mode of operation on receipt of a break signal from the attached terminal: 0 - do nothing 1 - send Interrupt packet 2 - send Reset packet 4 - send Indication of Break packet 5 - send Interrupt packet and Indication of Break packet 8 - escape from data transfer state 21 - discard output, send Interrupt packet, and send Indication of Break Packet " ::= { cdx6500CfgPadProfileEntry 9 } cdx6500padprofPar9 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "#9, controls padding after carriage return (CR): 0 - no padding after CR. 1 to 255 - number of padding characters inserted after CR." ::= { cdx6500CfgPadProfileEntry 10 } cdx6500padprofPar10 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "#10, controls line folding: 0 - no line folding. 1 to 255 - number of characters per line." ::= { cdx6500CfgPadProfileEntry 11 } cdx6500padprofPar12 OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "#12, specifies whether the PAD port is flow controlled (restrained from sending data) by the attached terminal sending the XON, XOFF characters. Also called Data Restraint Outbound (DRO) using in-band control: 0 - no control with XON, XOFF 1 - allow flow control on outbound data and service signals For DRO control using V.24 connector control signals (CTS and pin 14), use parameter #105." ::= { cdx6500CfgPadProfileEntry 12 } cdx6500padprofPar13 OBJECT-TYPE SYNTAX DisplayString (SIZE(1..7)) ACCESS read-only STATUS mandatory DESCRIPTION "#13, controls line feed insertion after carriage return (CR) in data transfer state: 0 - no line feed insertion 1 - after CR in data sent to attached device 2 - after CR in data from the attached device 4 - after echo of CR to attached device X - any combination of the above values." ::= { cdx6500CfgPadProfileEntry 13 } cdx6500padprofPar14 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "#14, controls padding after line feed in the data transfer state: 0 - no padding after line feed 1 to 255 - number of padding characters inserted after line feed." ::= { cdx6500CfgPadProfileEntry 14 } cdx6500padprofPar15 OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "#15, controls local editing in data transfer state: 0 - no editing 1 - allow editing (idle timer data forwarding must be disabled, parameter #4 = 0) Editing is limited to deleting single characters, deleting the entered line and displaying the entered line." ::= { cdx6500CfgPadProfileEntry 15 } cdx6500padprofPar16 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "#16, decimal value of ASCII character used to delete a character if editing is enabled (parameter #15 = 1)." ::= { cdx6500CfgPadProfileEntry 16 } cdx6500padprofPar17 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "#17, decimal value of ASCII character used to delete a line if editing is enabled (parameter #15 = 1)." ::= { cdx6500CfgPadProfileEntry 17 } cdx6500padprofPar18 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "#18, decimal value of ASCII character used to display a line if editing is enabled (parameter #15 = 1)." ::= { cdx6500CfgPadProfileEntry 18 } cdx6500padprofPar19 OBJECT-TYPE SYNTAX INTEGER (0..126) ACCESS read-only STATUS mandatory DESCRIPTION "#19, specifies the type of character delete service signal sent by PAD: 0 - no service signal 1 - printing terminals (PAD sends \\ for each delete character received from terminal) 2 - display terminals (PAD sends for each delete character received from terminal) 8,32-126 - specifies the ASCII character used as the editing service signal." ::= { cdx6500CfgPadProfileEntry 19 } cdx6500padprofPar20 OBJECT-TYPE SYNTAX DisplayString (SIZE(1..22)) ACCESS read-only STATUS mandatory DESCRIPTION "#20, specifies the echo mask: 0 - no echo mask (all characters echoed) 1 - no echo of CR 2 - no echo of LF 4 - no echo of VT, HT, or FF 8 - no echo of BEL or BS 16 - no echo of ESC or ENQ 32 - no echo of ACK, NAK, STX, SOH, EOT, ETB, or ETX 64 - no echo of editing characters as designated by parameters 16, 17 and 18 128 - no echo of all other characters in columns 0 and 1 of the ASCII table not mentioned above and character DEL XXX - any combination of the above values." ::= { cdx6500CfgPadProfileEntry 20 } cdx6500padprofPar21 OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "#21, controls the parity treatment of characters received and transmitted to the attached device. 0 - No parity checking or generation 1 - Parity checked on received characters 2 - Parity generated in transmitted characters 4 - Parity stripped from received characters x - any combination of the above values." ::= { cdx6500CfgPadProfileEntry 21 } cdx6500padprofPar22 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "#22, controls page wait: 0 - page wait disabled. 1 to 255 - number of line feed characters sent by the PAD for the page wait function." ::= { cdx6500CfgPadProfileEntry 22 } cdx6500padprofPar100 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "#100, specifies the ASCII character used to simulate break for attached terminals that do not have a break key: 0 - no break character defined 1 to 127 - decimal value of the character used to simulate break." ::= { cdx6500CfgPadProfileEntry 23 } cdx6500padprofPar101 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "#101, specifies the ASCII character used to toggle echo substitution of entered data. This function available only if parameter #2 = 1: 0 - no echo substitution function 1 to 127 - decimal value of character to use to toggle on and off the echo substitution." ::= { cdx6500CfgPadProfileEntry 24 } cdx6500padprofPar102 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "#102, specifies the ASCII character used to echo all characters entered by the attached device when echo substitution is toggled on: 0 - no echo when echo substitution toggled on 1 to 127 - decimal value of character used as echo, if echoing is enabled by parameter #2 and substitution is enabled by parameter #101." ::= { cdx6500CfgPadProfileEntry 25 } cdx6500padprofPar103 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "#103, specifies the ASCII character used for the XON function: 0 to 255 - decimal value of the XON character " ::= { cdx6500CfgPadProfileEntry 26 } cdx6500padprofPar104 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "#104, specifies the ASCII character used for the XOFF function: 0 to 255 - decimal value of the XOFF character." ::= { cdx6500CfgPadProfileEntry 27 } cdx6500padprofPar105 OBJECT-TYPE SYNTAX DisplayString (SIZE(1..5)) ACCESS read-only STATUS mandatory DESCRIPTION "#105, specifies whether both the PAD and the attached terminal are flow controlled (restrained from sending data) by the use of V.24 control signals, rather than XON, XOFF. This type of control is called out-of-band flow control. The control applies to data, commands and responses to and from an attached device: 0 - none using connector control signals 1 - Data Restraint Outbound, attached device flow controls PAD with connector pin 14 2 - Data Restraint Inbound, PAD flow controls attached device with connector pin 5, CTS X - any combination formed by summing (e.g. 1+2 or 3) For DRO control using XON/XOFF, use parameters #5 and #12." ::= { cdx6500CfgPadProfileEntry 28 } cdx6500padprofPar106 OBJECT-TYPE SYNTAX INTEGER (0..4) ACCESS read-only STATUS mandatory DESCRIPTION "#106, specifies parity of data sent to the network by the PAD: 0 - transparent - pass data as received 1 - space 2 - mark 3 - even 4 - odd" ::= { cdx6500CfgPadProfileEntry 29 } cdx6500padprofPar107 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "#107, is the elapsed time of no user data input after which a call on the port will be cleared: 0 - timer disabled 1 to 255 - timer value in minutes." ::= { cdx6500CfgPadProfileEntry 30 } cdx6500padprofPar108 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "#108, specifies the ASCII character used to disconnect a call: 0 - no character disconnects the call. 1 to 127 - decimal value of call disconnect character." ::= { cdx6500CfgPadProfileEntry 31 } cdx6500padprofPar109 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "#109, specifies the number of padding characters inserted in the data sent to the attached device after a form feed: 0 - no padding characters inserted. 1 to 255 - number of padding characters to insert after FF." ::= { cdx6500CfgPadProfileEntry 32 } cdx6500padprofPar110 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "#110, Selects the data forwarding delay after ESC is detected 0 - timer disabled. 1 to 255 - timer value in 1/20 second." ::= { cdx6500CfgPadProfileEntry 33 } cdx6500padprofPar111 OBJECT-TYPE SYNTAX INTEGER (0..3) ACCESS read-only STATUS mandatory DESCRIPTION "#111, Controls how the pad handles the echo of data when echo, parameter 2, is on. 0 - No Priority. Data is output and characters are echoed as they arrive. 1 - Input Priority. PAD holds output until input from terminal is finished. 2 - Output Priority. PAD will reecho input after output. 3 - Formatted Screen. PAD will echo one block of data for each prompt sent from host." ::= { cdx6500CfgPadProfileEntry 34 } cdx6500padprofPar112 OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "#112, Setting this parameter causes the PAD port to dynamically forward data packets, as bandwidth becomes available on the network link. Settings for X.3 parameters 1,2,3,4,15,16,17,18,19,20,100,101, 102,106,108,110,111 and 13 value 2,3,6 or 7 are ignored if parameter 112 is set. 0 - Dynamic forwarding turned off. 1 - Dynamic forwarding turned on." ::= { cdx6500CfgPadProfileEntry 35 } cdx6500padprofPar113 OBJECT-TYPE SYNTAX INTEGER (0..4) ACCESS read-only STATUS mandatory DESCRIPTION "#113, Controls Hewlett-Packard flow control. 0 - No HP flow control. 1 - HP host enq/ack control. 2 - HP terminal enq/ack control. 3 - HP host xon/xoff control. 4 - HP terminal xon/xoff control." ::= { cdx6500CfgPadProfileEntry 36 } cdx6500padprofPar114 OBJECT-TYPE SYNTAX INTEGER (0..2) ACCESS read-only STATUS mandatory DESCRIPTION "#114, Selects PAD operational mode: 0 - Normal PAD. 1 - Transparent Polled Async Host PAD. 2 - Transparent Polled Async Remote PAD." ::= { cdx6500CfgPadProfileEntry 37 } cdx6500padprofPar115 OBJECT-TYPE SYNTAX INTEGER (0..2) ACCESS read-only STATUS mandatory DESCRIPTION "#115, Selects Data Forwarding Criteria for Polled Async PADs: 0 - Normal. 1 - Short Timer. 2 - RTS Signal Drop." ::= { cdx6500CfgPadProfileEntry 38 } cdx6500padprofPar116 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "#116, Selects forwarding Short Timer duration for Polled Async PADs: 0 - Short Timer disabled. 1 to 255 - Duration of Short Timer in milliseconds." ::= { cdx6500CfgPadProfileEntry 39 } cdx6500padprofPar117 OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "#117, Selects EIA Signalling Action for Polled Async PADs: 0 - None. 1 - Raise DCD before transmission and drop DCD after transmission." ::= { cdx6500CfgPadProfileEntry 40 } cdx6500padprofPar118 OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "#118, Setting this parameter causes a Polled Async PAD to buffer complete async messages from the network before transmitting them to the attached device. 0 - Disabled. 1 - Enabled." ::= { cdx6500CfgPadProfileEntry 41 } cdx6500padprofPar119 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "#119, This parameter specifies the amount of time that DCD is held high before data transmission to the attached device begins. This parameter is used when EIA Signalling Action (#117) is configured to 1. 0 - DCD to Data Timer disabled. 1 to 255 - Duration of DCD to Data Timer in milliseconds." ::= { cdx6500CfgPadProfileEntry 42 } -- The Remote Pad Parameter Configuration Table cdx6500CfgRemotePadTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500CfgRemotePadEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the configuration parameters relevant to the Remote Pad Paramter table." ::= { cdx6500CfgGeneralGroup 9 } cdx6500CfgRemotePadEntry OBJECT-TYPE SYNTAX Cdx6500CfgRemotePadEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Remote Pad configuration parameters" INDEX { cdx6500remotepadEntryNum } ::= { cdx6500CfgRemotePadTable 1 } Cdx6500CfgRemotePadEntry ::= SEQUENCE { cdx6500remotepadEntryNum INTEGER, cdx6500remotepadParamNum1 INTEGER, cdx6500remotepadParamVal1 INTEGER, cdx6500remotepadParamNum2 INTEGER, cdx6500remotepadParamVal2 INTEGER, cdx6500remotepadParamNum3 INTEGER, cdx6500remotepadParamVal3 INTEGER, cdx6500remotepadParamNum4 INTEGER, cdx6500remotepadParamVal4 INTEGER, cdx6500remotepadParamNum5 INTEGER, cdx6500remotepadParamVal5 INTEGER, cdx6500remotepadParamNum6 INTEGER, cdx6500remotepadParamVal6 INTEGER, cdx6500remotepadParamNum7 INTEGER, cdx6500remotepadParamVal7 INTEGER, cdx6500remotepadParamNum8 INTEGER, cdx6500remotepadParamVal8 INTEGER, cdx6500remotepadParamNum9 INTEGER, cdx6500remotepadParamVal9 INTEGER, cdx6500remotepadParamNum10 INTEGER, cdx6500remotepadParamVal10 INTEGER, cdx6500remotepadParamNum11 INTEGER, cdx6500remotepadParamVal11 INTEGER, cdx6500remotepadParamNum12 INTEGER, cdx6500remotepadParamVal12 INTEGER, cdx6500remotepadParamNum13 INTEGER, cdx6500remotepadParamVal13 INTEGER, cdx6500remotepadParamNum14 INTEGER, cdx6500remotepadParamVal14 INTEGER, cdx6500remotepadParamNum15 INTEGER, cdx6500remotepadParamVal15 INTEGER, cdx6500remotepadParamNum16 INTEGER, cdx6500remotepadParamVal16 INTEGER, cdx6500remotepadParamNum17 INTEGER, cdx6500remotepadParamVal17 INTEGER, cdx6500remotepadParamNum18 INTEGER, cdx6500remotepadParamVal18 INTEGER, cdx6500remotepadParamNum19 INTEGER, cdx6500remotepadParamVal19 INTEGER, cdx6500remotepadParamNum20 INTEGER, cdx6500remotepadParamVal20 INTEGER, cdx6500remotepadParamNum21 INTEGER, cdx6500remotepadParamVal21 INTEGER, cdx6500remotepadParamNum22 INTEGER, cdx6500remotepadParamVal22 INTEGER } cdx6500remotepadEntryNum OBJECT-TYPE SYNTAX INTEGER (1..6) ACCESS read-only STATUS mandatory DESCRIPTION "This is not a configuration parameter. Instead, it identifies the particular PAD Parameter Table entry being configured by the other parameters in the record. This value is referenced by the parameter Remote PAD Parameter Number in the PAD Port Record." ::= { cdx6500CfgRemotePadEntry 1 } cdx6500remotepadParamNum1 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 2 } cdx6500remotepadParamVal1 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 3 } cdx6500remotepadParamNum2 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 4 } cdx6500remotepadParamVal2 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 5 } cdx6500remotepadParamNum3 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 6 } cdx6500remotepadParamVal3 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 7 } cdx6500remotepadParamNum4 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 8 } cdx6500remotepadParamVal4 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 9 } cdx6500remotepadParamNum5 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 10 } cdx6500remotepadParamVal5 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 11 } cdx6500remotepadParamNum6 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 12 } cdx6500remotepadParamVal6 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 13 } cdx6500remotepadParamNum7 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 14 } cdx6500remotepadParamVal7 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 15 } cdx6500remotepadParamNum8 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 16 } cdx6500remotepadParamVal8 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 17 } cdx6500remotepadParamNum9 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 18 } cdx6500remotepadParamVal9 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 19 } cdx6500remotepadParamNum10 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 20 } cdx6500remotepadParamVal10 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 21 } cdx6500remotepadParamNum11 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 22 } cdx6500remotepadParamVal11 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 23 } cdx6500remotepadParamNum12 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 24 } cdx6500remotepadParamVal12 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 25 } cdx6500remotepadParamNum13 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 26 } cdx6500remotepadParamVal13 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 27 } cdx6500remotepadParamNum14 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 28 } cdx6500remotepadParamVal14 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 29 } cdx6500remotepadParamNum15 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 30 } cdx6500remotepadParamVal15 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 31 } cdx6500remotepadParamNum16 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 32 } cdx6500remotepadParamVal16 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 33 } cdx6500remotepadParamNum17 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 34 } cdx6500remotepadParamVal17 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 35 } cdx6500remotepadParamNum18 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 36 } cdx6500remotepadParamVal18 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 37 } cdx6500remotepadParamNum19 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 38 } cdx6500remotepadParamVal19 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 39 } cdx6500remotepadParamNum20 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 40 } cdx6500remotepadParamVal20 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 41 } cdx6500remotepadParamNum21 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 42 } cdx6500remotepadParamVal21 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 43 } cdx6500remotepadParamNum22 OBJECT-TYPE SYNTAX INTEGER (0..127) ACCESS read-only STATUS mandatory DESCRIPTION "Reference number of X.3 parameter sent to remote PAD when a connection is made to a PAD port in this node. Standard parameters and function are: 1 - PAD recall character 12 - data restraint out 2 - echo on/off 13 - insertion after 3 - forwarding, character 14 - padding 4 - forwarding, timer 15 - editing 5 - data restraint in 16 - character delete 6 - service signals 17 - line delete 7 - break handling 18 - line display 8 - discard output 19 - editing type 9 - padding 20 - echo mask 10 - line folding 21 - parity treatment 11 - speed 22 - page wait " ::= { cdx6500CfgRemotePadEntry 44 } cdx6500remotepadParamVal22 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "Corresponding value of referenced X.3 parameter sent to remote PAD when connection is made. Valid range of parameter value depends on parameter." ::= { cdx6500CfgRemotePadEntry 45 } END