OPLINK-BTI-OPS-MIB :: opsmRevertiveSetting

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsOPLINK-BTI-OPS-MIBopsmRevertiveSetting

opsmRevertiveSetting

Module: OPLINK-BTI-OPS-MIB

OID (symbolic): OPLINK-BTI-OPS-MIB::opsmRevertiveSetting

OID (numeric): 1.3.6.1.4.1.19547.1.7.1.2.1.21

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: The action when the opticial of primary channel is resumed. 0: Non-Revertive, 1: Revertive.

What is opsmRevertiveSetting?

Controls whether this OPSM module automatically switches back to the primary path once its optical signal is resumed: 0 for non-revertive (stay on the current path) or 1 for revertive (switch back automatically).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19547.1.7.1.2.1.21
snmpwalk -v2c -c public <target> OPLINK-BTI-OPS-MIB::opsmRevertiveSetting

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.19547.1.7.1.2.1.21.1
snmpget -v2c -c public <target> OPLINK-BTI-OPS-MIB::opsmRevertiveSetting.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.19547.1.7.1.2.1.21.1 i <value>

Start monitoring Oplink BTI optical networking module, optical transport/DWDM equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OPLINK-BTI-OPS-MIB::opsmRevertiveSetting OID value, configure state conditions and alerts, and monitor any Oplink BTI optical networking module, optical transport/DWDM equipment from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.19547oplinkOplink-MIB
1.3.6.1.4.1.19547.1mngdproductsOplink-MIB
Numeric OIDNameModule
1.3.6.1.4.1.19547.1.7deviceOPSMv2_MIBOPLINK-BTI-OPS-MIB
1.3.6.1.4.1.19547.1.7.1version2OPLINK-BTI-OPS-MIB
1.3.6.1.4.1.19547.1.7.1.2opsmTableOPLINK-BTI-OPS-MIB
1.3.6.1.4.1.19547.1.7.1.2.1opsmEntryOPLINK-BTI-OPS-MIB
1.3.6.1.4.1.19547.1.7.1.2.1.21opsmRevertiveSettingOPLINK-BTI-OPS-MIB