OPLINK-BTI-OPS-MIB :: opsmInputLosAlarmHys

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsOPLINK-BTI-OPS-MIBopsmInputLosAlarmHys

opsmInputLosAlarmHys

Module: OPLINK-BTI-OPS-MIB

OID (symbolic): OPLINK-BTI-OPS-MIB::opsmInputLosAlarmHys

OID (numeric): 1.3.6.1.4.1.19547.1.7.1.2.1.42

Node type: OBJECT-TYPE

Type: HeTenthdBm

Access: read-write

Description: The input los alarm hystersis on both path default: 10,(Unit:0.1dB),range: 10--30

What is opsmInputLosAlarmHys?

The hysteresis applied to the loss-of-signal alarm thresholds on both the primary and secondary paths of this OPSM module, in tenths of a dB. Default 10 (1.0dB), settable 10-30; prevents alarm flapping when input power hovers right at the LOS threshold.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19547.1.7.1.2.1.42
snmpwalk -v2c -c public <target> OPLINK-BTI-OPS-MIB::opsmInputLosAlarmHys

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.19547.1.7.1.2.1.42.1
snmpget -v2c -c public <target> OPLINK-BTI-OPS-MIB::opsmInputLosAlarmHys.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.19547.1.7.1.2.1.42.1 s <value>

Start monitoring Oplink BTI optical networking module, optical transport/DWDM equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OPLINK-BTI-OPS-MIB::opsmInputLosAlarmHys OID value, configure state conditions and alerts, and monitor any Oplink BTI optical networking module, optical transport/DWDM equipment from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.19547oplinkOplink-MIB
1.3.6.1.4.1.19547.1mngdproductsOplink-MIB
Numeric OIDNameModule
1.3.6.1.4.1.19547.1.7deviceOPSMv2_MIBOPLINK-BTI-OPS-MIB
1.3.6.1.4.1.19547.1.7.1version2OPLINK-BTI-OPS-MIB
1.3.6.1.4.1.19547.1.7.1.2opsmTableOPLINK-BTI-OPS-MIB
1.3.6.1.4.1.19547.1.7.1.2.1opsmEntryOPLINK-BTI-OPS-MIB
1.3.6.1.4.1.19547.1.7.1.2.1.42opsmInputLosAlarmHysOPLINK-BTI-OPS-MIB