OPLINK-BTI-OPS-MIB :: emuHighTemperatureThreshold

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsOPLINK-BTI-OPS-MIBemuHighTemperatureThreshold

emuHighTemperatureThreshold

Module: OPLINK-BTI-OPS-MIB

OID (symbolic): OPLINK-BTI-OPS-MIB::emuHighTemperatureThreshold

OID (numeric): 1.3.6.1.4.1.19547.1.7.1.1.1.18

Node type: OBJECT-TYPE

Type: HeTenthCentigrade

Access: read-write

Description: HighTempThreshold. Get/Set high temperature threshold value of EMU card(Unit: 0.1 degree celsuis), range:550~750

What is emuHighTemperatureThreshold?

The high-temperature alarm threshold for the EMU controller card, in tenths of a degree Celsius, settable in the range 550-750 (55.0-75.0C). Raising or lowering this tunes how sensitive the card's thermal alarm is.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19547.1.7.1.1.1.18
snmpwalk -v2c -c public <target> OPLINK-BTI-OPS-MIB::emuHighTemperatureThreshold

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.19547.1.7.1.1.1.18.1
snmpget -v2c -c public <target> OPLINK-BTI-OPS-MIB::emuHighTemperatureThreshold.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.19547.1.7.1.1.1.18.1 s <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> emuHighTemperatureThreshold.1

Start monitoring Oplink BTI optical networking module, optical transport/DWDM equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OPLINK-BTI-OPS-MIB::emuHighTemperatureThreshold OID value, configure state conditions and alerts, and monitor any Oplink BTI optical networking module, optical transport/DWDM equipment from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.19547oplinkOplink-MIB
1.3.6.1.4.1.19547.1mngdproductsOplink-MIB
Numeric OIDNameModule
1.3.6.1.4.1.19547.1.7deviceOPSMv2_MIBOPLINK-BTI-OPS-MIB
1.3.6.1.4.1.19547.1.7.1version2OPLINK-BTI-OPS-MIB
1.3.6.1.4.1.19547.1.7.1.1emuTableOPLINK-BTI-OPS-MIB
1.3.6.1.4.1.19547.1.7.1.1.1emuEntryOPLINK-BTI-OPS-MIB
1.3.6.1.4.1.19547.1.7.1.1.1.18emuHighTemperatureThresholdOPLINK-BTI-OPS-MIB