ONS15501-MIB :: ons15501LaserStatus

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsONS15501-MIBons15501LaserStatus

ons15501LaserStatus

Module: ONS15501-MIB

OID (symbolic): ONS15501-MIB::ons15501LaserStatus

OID (numeric): 1.3.6.1.4.1.1869.11.11.2.13

Node type: OBJECT-TYPE

Type: Ons15501AlarmStatus

Access: read-only

Description: Gives the status of the laser pumps.

What is ons15501LaserStatus?

This OID reports the status of the unit's laser pumps as an alarm severity level (critical, major, minor, info, or noAlarm). An admin watches this closely since a degraded or failed laser pump directly impacts the amplifier's ability to boost the optical signal.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1869.11.11.2.13
snmpwalk -v2c -c public <target> ONS15501-MIB::ons15501LaserStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1869.11.11.2.13.1
snmpget -v2c -c public <target> ONS15501-MIB::ons15501LaserStatus.1

Start monitoring Cisco ONS 15501 EDFA optical amplifier (optical power/alarm and software image status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ONS15501-MIB::ons15501LaserStatus OID value, configure state conditions and alerts, and monitor any Cisco ONS 15501 EDFA optical amplifier (optical power/alarm and software image status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1869synchronousONS15501-MIB
1.3.6.1.4.1.1869.11synEmbLxONS15501-MIB
1.3.6.1.4.1.1869.11.11ons15501MIBONS15501-MIB
1.3.6.1.4.1.1869.11.11.2ons15501AttrONS15501-MIB
1.3.6.1.4.1.1869.11.11.2.13ons15501LaserStatusONS15501-MIB