OMNI-gx2LM-MIB :: minorHighTecCurrent

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OMNI-gx2LM-MIB › minorHighTecCurrent

minorHighTecCurrent

Module: OMNI-gx2LM-MIB

OID (symbolic): OMNI-gx2LM-MIB::minorHighTecCurrent

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.4.2.1.61

Node type: OBJECT-TYPE

Type: Float

Access: read-only

Description: The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.

What is minorHighTecCurrent?

This holds the minor-high alarm threshold for the TEC Current parameter, in mA, set tighter than majorHighTecCurrent so it trips earlier as an early warning. Crossing it raises a minorHighAlarm in alarmStateTecCurrent, letting an admin notice the current drawn by the thermoelectric cooler that holds the laser diode at its target temperature drifting high before it reaches the more serious major-high threshold.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.4.2.1.61
snmpwalk -v2c -c public <target> OMNI-gx2LM-MIB::minorHighTecCurrent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.4.2.1.61.1
snmpget -v2c -c public <target> OMNI-gx2LM-MIB::minorHighTecCurrent.1

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 LM laser transmitter module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2LM-MIB::minorHighTecCurrent OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 LM laser transmitter module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.4gx2LmGX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.4.2gx2lmAnalogTableOMNI-gx2LM-MIB
1.3.6.1.4.1.1166.6.1.2.4.2.1gx2lmAnalogEntryOMNI-gx2LM-MIB
1.3.6.1.4.1.1166.6.1.2.4.2.1.61minorHighTecCurrentOMNI-gx2LM-MIB