OMNI-gx2LM-MIB :: maxValueTecCurrent

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OMNI-gx2LM-MIB › maxValueTecCurrent

maxValueTecCurrent

Module: OMNI-gx2LM-MIB

OID (symbolic): OMNI-gx2LM-MIB::maxValueTecCurrent

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.4.2.1.66

Node type: OBJECT-TYPE

Type: Float

Access: read-only

Description: The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.

What is maxValueTecCurrent?

This reports the maximum value the TEC Current parameter can physically achieve on this hardware, in mA. An admin uses this alongside minValueTecCurrent to know the full valid range for the current drawn by the thermoelectric cooler that holds the laser diode at its target temperature before configuring alarm thresholds or a control setting.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.4.2.1.66
snmpwalk -v2c -c public <target> OMNI-gx2LM-MIB::maxValueTecCurrent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.4.2.1.66.1
snmpget -v2c -c public <target> OMNI-gx2LM-MIB::maxValueTecCurrent.1

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 LM laser transmitter module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2LM-MIB::maxValueTecCurrent OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 LM laser transmitter module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.4gx2LmGX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.4.2gx2lmAnalogTableOMNI-gx2LM-MIB
1.3.6.1.4.1.1166.6.1.2.4.2.1gx2lmAnalogEntryOMNI-gx2LM-MIB
1.3.6.1.4.1.1166.6.1.2.4.2.1.66maxValueTecCurrentOMNI-gx2LM-MIB