OMNI-gx2LM-MIB :: majorLow12Volt

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OMNI-gx2LM-MIB › majorLow12Volt

majorLow12Volt

Module: OMNI-gx2LM-MIB

OID (symbolic): OMNI-gx2LM-MIB::majorLow12Volt

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.4.2.1.104

Node type: OBJECT-TYPE

Type: Float

Access: read-only

Description: The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.

What is majorLow12Volt?

This holds the major-low alarm threshold configured for the 12-Volt Supply parameter, in V. If currentValue12Volt falls below this threshold, the module raises a majorLowAlarm condition reflected in alarmState12Volt, signaling a serious low-side deviation in the module's internal 12-volt power supply rail voltage. An admin sets this as the floor beyond which the reading is considered a significant fault rather than normal variation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.4.2.1.104
snmpwalk -v2c -c public <target> OMNI-gx2LM-MIB::majorLow12Volt

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.4.2.1.104.1
snmpget -v2c -c public <target> OMNI-gx2LM-MIB::majorLow12Volt.1

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 LM laser transmitter module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2LM-MIB::majorLow12Volt OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 LM laser transmitter module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.4gx2LmGX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.4.2gx2lmAnalogTableOMNI-gx2LM-MIB
1.3.6.1.4.1.1166.6.1.2.4.2.1gx2lmAnalogEntryOMNI-gx2LM-MIB
1.3.6.1.4.1.1166.6.1.2.4.2.1.104majorLow12VoltOMNI-gx2LM-MIB