ODSLANBlazer7000-MIB :: lanBlazer7000TempIndex

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › ODSLANBlazer7000-MIB › lanBlazer7000TempIndex

lanBlazer7000TempIndex

Module: ODSLANBlazer7000-MIB

OID (symbolic): ODSLANBlazer7000-MIB::lanBlazer7000TempIndex

OID (numeric): 1.3.6.1.4.1.50.8.1.2.1.3.4.1.1.1

Node type: OBJECT-TYPE

Type: ResourceId

Access: read-only

Description: A unique index that identifies this temperature probe. This index corresponds to the lanBlazer7000ResourceIndex for temperature probe type resources.

What is lanBlazer7000TempIndex?

Uniquely identifies a given temperature probe, using the same numbering as lanBlazer7000ResourceIndex for temperature-probe-type resources. It lets an admin match a specific probe's readings and thresholds in this table back to its physical location (e.g. chassis intake vs. a particular module) via the resource table.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.3.4.1.1.1
snmpwalk -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000TempIndex

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.3.4.1.1.1.1
snmpget -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000TempIndex.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> lanBlazer7000TempIndex.1

Start monitoring ODS LANBlazer 7000 WAN test/analysis instrument with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ODSLANBlazer7000-MIB::lanBlazer7000TempIndex OID value, configure state conditions and alerts, and monitor any ODS LANBlazer 7000 WAN test/analysis instrument from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.50odsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8odsTPSODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1odsLANBlazerODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2odsLANBlazerMibsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1odsLANBlazer7000MibODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3lanBlazer7000ChassisODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.4lanBlazer7000TemperatureODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.4.1lanBlazer7000TempTableODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.4.1.1lanBlazer7000TempEntryODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.4.1.1.1lanBlazer7000TempIndexODSLANBlazer7000-MIB