-- ODS LANBLAZER 7000 MIB -- ODS LANBlazer 7000 Enterprise Specific Management Information Base for SNMP version 1 -- Copyright (c) 1997, ODS Networks Inc. -- This MIB document is provided "as-is". ODS reserves the right to make -- changes without prior notification. An explicit right to copy this document is provided -- to all. However, the intellectual content of this document is the exclusive property -- of ODS. -- For technical assistance, please contact ODS at: -- email: -- phone: -- fax: -- INTRODUCTION -- -- Welcome to the ODS LANBlazer 7000 Enterprise-Specific MIB. -- -- This MIB is supplied to enhance the management capability of the LANBlazer 7000 System. -- It provides managed objects that supplement those capabilities supported by the standard -- IETF MIBs. -- -- The MIB has the following main sections: -- -- General Agent Support: Manages the SNMP agent. -- Communications: -- Resource Management: The Resource Manager is the focal point for managing dynamic resources. -- Chassis: Objects related to the management of the physical enclosure and environment. -- Switching: Management of the layer II switching functions and Virtual LANs. -- Event Management: RMON Events on steroids. -- File System: Provides access to the embedded file system. -- MODULE DEFINITION ODSLANBlazer7000-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, Gauge, NetworkAddress, IpAddress,Counter, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215; -- Textual Conventions -- The Data Type returned in event log value EventValueType ::= INTEGER { none(1), integer(2), longInteger(3), string(4), octets(5), ipAddress(6), macAddress(7), timeTicks(8) } -- the resources managed by the LANBlazer 7000 Switch ResourceType ::= INTEGER { system(1), module(2), fan(3), temperatureSensor(4), interface(5), powerSupply(6), display(7), switchPort(8), bridge(9), vlan(10), aft(11), inboundGroupTable(12), outboundGroupTable(13), threeComMappingTable(14), event(15), alarm(16) } -- This data type is used to uniquely identify a resource within the LANBlazer 7000 Switch. -- It encodes the Resource ID into an OID, using 2 as the first component. -- Using a 2 works around the OID encoding restrictions of the first component (ASN.1) ResourceId ::= OBJECT IDENTIFIER DisplayString ::= OCTET STRING -- This data type is used to model textual information taken -- from the NVT ASCII character set. By convention, objects -- with this syntax are declared as having -- -- SIZE (0..255) RowStatus ::= INTEGER { -- the following two values are states: -- these values may be read or written active(1), notInService(2), -- the following value is a state: -- this value may be read, but not written notReady(3), -- the following three values are -- actions: these values may be written, -- but are never read createAndGo(4), createAndWait(5), destroy(6) } -- All representations of MAC addresses in this MIB Module -- use, as a textual convention (i.e. this convention does -- not affect their encoding), the data type: MacAddress ::= OCTET STRING (SIZE (6)) -- a 6 octet address in the "canonical" order -- defined by IEEE 802.1a, i.e., as if it were transmitted -- least significant bit first, even though 802.5 (in -- contrast to other n802.x protocols) requires MAC -- addresses to be transmitted most significant bit first. -- -- 16-bit addresses, if needed, are represented by setting -- their upper 4 octets to all 0's, i.e., AAFF would be -- represented as 00000000AAFF. -- Similarly, all representations of Bridge-Id in this MIB -- Module use, as a textual convention (i.e. this -- convention does not affect their encoding), the data -- type: BridgeId ::= OCTET STRING (SIZE (8)) -- the Bridge-Identifier as used in the Spanning Tree -- Protocol to uniquely identify a bridge. Its first two -- octets (in network byte order) contain a priority -- value and its last 6 octets contain the MAC address -- used to refer to a bridge in a unique fashion -- (typically, the numerically smallest MAC address -- of all ports on the bridge). -- Several objects in this MIB module represent values of -- timers used by the Spanning Tree Protocol. In this -- MIB, these timers have values in units of hundredths of -- a second (i.e. 1/100 secs). -- These timers, when stored in a Spanning Tree Protocol's -- BPDU, are in units of 1/256 seconds. Note, however, -- that 802.1D-1990 specifies a settable granularity of -- no more than 1 second for these timers. To avoid -- ambiguity, a data type is defined here as a textual -- convention and all representation of these timers -- in this MIB module are defined using this data type. An -- algorithm is also defined for converting between the -- different units, to ensure a timer's value is not -- distorted by multiple conversions. -- The data type is: -- a STP timer in units of 1/100 seconds Timeout ::= INTEGER -- To convert a Timeout value into a value in units of -- 1/256 seconds, the following algorithm should be used: -- -- b = floor( (n * 256) / 100) -- -- where: -- floor = quotient [ignore remainder] -- n is the value in 1/100 second units -- b is the value in 1/256 second units -- -- To convert the value from 1/256 second units back to -- 1/100 seconds, the following algorithm should be used: -- -- n = ceiling( (b * 100) / 256) -- -- where: -- ceiling = quotient [if remainder is 0], or -- quotient + 1 [if remainder is non-zero] -- n is the value in 1/100 second units -- b is the value in 1/256 second units -- -- Note: it is important that the arithmetic operations are -- done in the order specified (i.e., multiply first, divide -- second). -- Event Category Macro -- -- Indicates the type of event: -- - coldstart is generated at system bootup -- - warmstart is generated when the software system (only) resets -- - system error is generated for a variety of reasons including running out of memory, OS errors, and H/W faults -- - status change indicates a change in the status value e.g. a port status change -- - configuration indicates a change in the configuration value e.g. a port mode change -- - scheduled events are triggered based on a calendar event -- - authentication indicates attempted access to a restricted resource without the proper credentials, e.g. SNMP -- authentication failure. -- - threshold is generated by alarms EventCategory ::= INTEGER { userDefined(1), coldstart(2), warmstart(3), linkUp(4), linkDown(5), newResource(6), deletedResource(7), tempStatus(8), configuration(9), scheduled(10), authentication(11), system(12), risingThreshold(13), fallingThreshold(14), fanStatus(15), powerStatus(16), status(17), bridgeNewRoot(18), bridgeTopChange(19), switchFabricStatus(20) } ods OBJECT IDENTIFIER ::= { enterprises 50 } odsTPS OBJECT IDENTIFIER ::= { ods 8 } odsLANBlazer OBJECT IDENTIFIER ::= { odsTPS 1 } odsLANBlazerMibs OBJECT IDENTIFIER ::= { odsLANBlazer 2 } odsLANBlazer7000Mib OBJECT IDENTIFIER ::= { odsLANBlazerMibs 1 } -- v2 STUFF -- odsLANBlazer7000MIB MODULE-IDENTITY -- LAST-UPDATED "9701030000Z" -- ORGANIZATION "ODS" -- CONTACT-INFO -- " Technical Support -- -- Postal: TBD -- -- -- -- Tel: TBD -- Fax: TBD -- -- E-mail: -- DESCRIPTION -- "ODS LANBlazer 7000 Enterprise Specific MIB Module" -- ::= {} -- AGENT lanBlazer7000Agent OBJECT IDENTIFIER ::= { odsLANBlazer7000Mib 1 } -- GENERAL AGENT lanBlazer7000AgentGen OBJECT IDENTIFIER ::= { lanBlazer7000Agent 1 } lanBlazer7000AgentMIBVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "The version of the LANBlazer 700 Enterprise Specific MIB that this agent supports." ::= { lanBlazer7000AgentGen 1 } lanBlazer7000AgentMgrIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object represents the index into the community table that is used to authenticate SNMP requests for this manager." ::= { lanBlazer7000AgentGen 2 } -- COMMUNITY TABLE lanBlazer7000AgentCommunity OBJECT IDENTIFIER ::= { lanBlazer7000Agent 2 } -- -- The community table is the database used by the agent to authenticate SNMP requests -- and to generate SNMP traps. This table is only accessible for users with security clearance. -- lanBlazer7000CommunityTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000CommunityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { lanBlazer7000AgentCommunity 1 } lanBlazer7000CommunityEntry OBJECT-TYPE SYNTAX LanBlazer7000CommunityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { lanBlazer7000CommunityIndex } ::= { lanBlazer7000CommunityTable 1 } LanBlazer7000CommunityEntry ::= SEQUENCE { lanBlazer7000CommunityIndex INTEGER, lanBlazer7000CommunityString DisplayString, lanBlazer7000CommunityAddressType INTEGER, lanBlazer7000CommunityAddress NetworkAddress, lanBlazer7000CommunityAccess INTEGER, lanBlazer7000CommunityTrapReceiver INTEGER, lanBlazer7000CommunitySecurityLevel INTEGER, lanBlazer7000CommunityStatus RowStatus } lanBlazer7000CommunityIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this entry." ::= { lanBlazer7000CommunityEntry 1 } lanBlazer7000CommunityString OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "The community string included in the SNMP PDU used for authentication purposes." ::= { lanBlazer7000CommunityEntry 2 } lanBlazer7000CommunityAddressType OBJECT-TYPE SYNTAX INTEGER { any(1), ipv4(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of address associated with this community. If set to any(1), only the community string is authenticated." ::= { lanBlazer7000CommunityEntry 3 } lanBlazer7000CommunityAddress OBJECT-TYPE SYNTAX NetworkAddress ACCESS read-write STATUS mandatory DESCRIPTION "If the address type is any, then the value of this object is a null string. If the type is ipv4(2), then this value represents a 4 byte IP address." ::= { lanBlazer7000CommunityEntry 4 } lanBlazer7000CommunityAccess OBJECT-TYPE SYNTAX INTEGER { none(1), readOnly(2), readWrite(3), moreSpecific(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The MIB access supported for this community entry. A Get or GetNext SNMP PDU is authenticated if the value of this object is read-only(2) or read-write(3). A Set request will be honored if the value of this object is read-write(3). If more granular access control is desired, then the value of this object is set to more-specific(4), and the view table should be consulted. This enables the capability to set different access rights to different branches of the MIB for a particular community. " ::= { lanBlazer7000CommunityEntry 5 } lanBlazer7000CommunityTrapReceiver OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If set to enable(1), this community entry is considered a trap receiver. When the agent generates an SNMP trap, a copy will be sent to this host using this community string." ::= { lanBlazer7000CommunityEntry 6 } lanBlazer7000CommunitySecurityLevel OBJECT-TYPE SYNTAX INTEGER { normal(1), administrator(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Secure tables are only accessible from users with security clearance. For example, this table (the community table) is only accessible by parties that have the security clearance." ::= { lanBlazer7000CommunityEntry 7 } lanBlazer7000CommunityStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { lanBlazer7000CommunityEntry 8 } -- WEB SERVER lanBlazer7000AgentWeb OBJECT IDENTIFIER ::= { lanBlazer7000Agent 3 } lanBlazer7000AgentWebServerURL OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The URL of where the document server software is installed. The switch uses this location to find online help and bimapped graphics. Enter the host name or IP address of the HTTP server at the HTTP Server Location prompt, followed by ':2010'. For example, for a host named 'phantom,', enter 'http://phantom:2010'. If no server is desired or installed, set this object to the empty string." ::= { lanBlazer7000AgentWeb 1 } lanBlazer7000AgentWebServerHelpDirectory OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The subdirectory that contains the help files on the document server. Typically, this directory is 'help'." ::= { lanBlazer7000AgentWeb 2 } -- CHASSIS -- Chassis Family lanBlazer7000Chassis OBJECT IDENTIFIER ::= { odsLANBlazer7000Mib 3 } -- Chassis family of objects help manage modular devices, and their environmental -- parameters. lanBlazer7000ChassisGen OBJECT IDENTIFIER ::= { lanBlazer7000Chassis 1 } lanBlazer7000ChassisType OBJECT-TYPE SYNTAX INTEGER { p550(1), p220(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The model of the chassis that this agent is managing." ::= { lanBlazer7000ChassisGen 1 } lanBlazer7000ChassisSlots OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of slots available in this chassis. If this chassis is a stackable chassis, the total capacity of stacking units." ::= { lanBlazer7000ChassisGen 2 } -- INVENTORY lanBlazer7000Inventory OBJECT IDENTIFIER ::= { lanBlazer7000Chassis 2 } -- The inventory table contains manufacturing identification information of the -- components contained within the system. lanBlazer7000InventoryTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000InventoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of inventory information." ::= { lanBlazer7000Inventory 1 } lanBlazer7000InventoryEntry OBJECT-TYPE SYNTAX LanBlazer7000InventoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Inventory information related to this device." INDEX { lanBlazer7000InventoryResourceType, lanBlazer7000InventoryResourceIndex } ::= { lanBlazer7000InventoryTable 1 } LanBlazer7000InventoryEntry ::= SEQUENCE { lanBlazer7000InventoryResourceType ResourceType, lanBlazer7000InventoryResourceIndex ResourceId, lanBlazer7000InventoryModelNumber DisplayString, lanBlazer7000InventorySerialNumber DisplayString, lanBlazer7000InventoryVersion DisplayString, lanBlazer7000InventoryManufactureInfo DisplayString, lanBlazer7000InventoryScratchPad DisplayString } lanBlazer7000InventoryResourceType OBJECT-TYPE SYNTAX ResourceType ACCESS read-only STATUS mandatory DESCRIPTION "The resource class of this inventory item." ::= { lanBlazer7000InventoryEntry 1 } lanBlazer7000InventoryResourceIndex OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "The resource identifier of this inventory item." ::= { lanBlazer7000InventoryEntry 2 } lanBlazer7000InventoryModelNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "The model number of this device." ::= { lanBlazer7000InventoryEntry 3 } lanBlazer7000InventorySerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "The serial number of this device." ::= { lanBlazer7000InventoryEntry 4 } lanBlazer7000InventoryVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "The revision number of this device." ::= { lanBlazer7000InventoryEntry 5 } lanBlazer7000InventoryManufactureInfo OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "Information related to the manufacturing of this device." ::= { lanBlazer7000InventoryEntry 6 } lanBlazer7000InventoryScratchPad OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) ACCESS read-write STATUS mandatory DESCRIPTION "A scratch pad area available for keeping user-supplied inventory information. " ::= { lanBlazer7000InventoryEntry 7 } -- -- Power Systems lanBlazer7000PowerSystems OBJECT IDENTIFIER ::= { lanBlazer7000Chassis 3 } -- POWER SUPPLY TABLE lanBlazer7000PowerSupplies OBJECT IDENTIFIER ::= { lanBlazer7000PowerSystems 1 } -- A table providing information about each power supply. -- The index to the table is the power supply resource index. -- -- Information in this table includes the status of the power supply -- and how much power this supply generates. lanBlazer7000PowerSupplyTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000PowerSupplyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of information related to each power supply in the system." ::= { lanBlazer7000PowerSupplies 1 } lanBlazer7000PowerSupplyEntry OBJECT-TYPE SYNTAX LanBlazer7000PowerSupplyEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry providing information about a particular power supply in the system." INDEX { lanBlazer7000PowerSupplyIndex } ::= { lanBlazer7000PowerSupplyTable 1 } LanBlazer7000PowerSupplyEntry ::= SEQUENCE { lanBlazer7000PowerSupplyIndex ResourceId, lanBlazer7000PowerSupplyType INTEGER, lanBlazer7000PowerSupplyStatus INTEGER, lanBlazer7000PowerSupplyInputStatus INTEGER, lanBlazer7000PowerSupplyOutputStatus INTEGER, lanBlazer7000PowerSupplyOutputCapacity INTEGER } lanBlazer7000PowerSupplyIndex OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this power supply. This index corresponds to the lanBlazer7000ResourceIndex of the power supply type resource." ::= { lanBlazer7000PowerSupplyEntry 1 } lanBlazer7000PowerSupplyType OBJECT-TYPE SYNTAX INTEGER { unknown(1), psA(2), psB(3) } ACCESS read-only STATUS mandatory DESCRIPTION "An enumerated integer describing the type of power supply. " ::= { lanBlazer7000PowerSupplyEntry 2 } lanBlazer7000PowerSupplyStatus OBJECT-TYPE SYNTAX INTEGER { okay(1), faulty(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of this power supply. Okay(1) indicates the power supply is operating properly. Faulty(2) indicates that the power supply is not functioning properly. In this case, more information can be determined from the other power supply attributes." ::= { lanBlazer7000PowerSupplyEntry 3 } lanBlazer7000PowerSupplyInputStatus OBJECT-TYPE SYNTAX INTEGER { okay(1), faulty(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the input power feed (e.g. the AC power cord) to this power supply." ::= { lanBlazer7000PowerSupplyEntry 4 } lanBlazer7000PowerSupplyOutputStatus OBJECT-TYPE SYNTAX INTEGER { okay(1), faulty(2), unknown(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the output power from this power supply." ::= { lanBlazer7000PowerSupplyEntry 5 } lanBlazer7000PowerSupplyOutputCapacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total capacity of power supplied by this supply in Watts." ::= { lanBlazer7000PowerSupplyEntry 6 } -- POWER MANAGEMENT lanBlazer7000PowerMgmtGen OBJECT IDENTIFIER ::= { lanBlazer7000PowerSystems 2 } lanBlazer7000PowerCapacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total capacity (in Watts) of power available (currently) in the system." ::= { lanBlazer7000PowerMgmtGen 1 } lanBlazer7000PowerUsed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total power (in Watts) currently being consumed in the system." ::= { lanBlazer7000PowerMgmtGen 2 } -- POWER MANAGEMENT CONTROL lanBlazer7000PowerMgmtCtl OBJECT IDENTIFIER ::= { lanBlazer7000PowerSystems 3 } lanBlazer7000PowerControlTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000PowerControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table manages the power attributes associated with each module." ::= { lanBlazer7000PowerMgmtCtl 1 } lanBlazer7000PowerControlEntry OBJECT-TYPE SYNTAX LanBlazer7000PowerControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the power control table manages the power attributes of the specified module." INDEX { lanBlazer7000ModuleIndex } ::= { lanBlazer7000PowerControlTable 1 } LanBlazer7000PowerControlEntry ::= SEQUENCE { lanBlazer7000PowerControlUsed INTEGER, lanBlazer7000PowerControlPriority INTEGER, lanBlazer7000PowerControlMode INTEGER } lanBlazer7000PowerControlUsed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total power (in Watts) used by this module." ::= { lanBlazer7000PowerControlEntry 1 } lanBlazer7000PowerControlPriority OBJECT-TYPE SYNTAX INTEGER { high(1), normal(2), low(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The priority of this module to be considered in the event of a power supply failure where the amount of power used exceeds the system capacity. Low priority modules will be powered down before higher priority modules." ::= { lanBlazer7000PowerControlEntry 2 } lanBlazer7000PowerControlMode OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), poweredDown(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Normally, a module power mode is enable(1). In the event of a power supply failure resulting in a power shortage, or in the event of this module being inserted without enough available power, the mode will be poweredDown(3). Setting this object to the value of poweredDown(3) will result in an error. When enough power is available, the module will power back up when in this mode. A module may be powered down through administrative action by setting the value of this object to disable(2). In this mode, the module will remain powered down until the mode is set back to enable." ::= { lanBlazer7000PowerControlEntry 3 } -- TEMPERATURE lanBlazer7000Temperature OBJECT IDENTIFIER ::= { lanBlazer7000Chassis 4 } lanBlazer7000TempTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000TempEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of information related to the temperature within the system." ::= { lanBlazer7000Temperature 1 } lanBlazer7000TempEntry OBJECT-TYPE SYNTAX LanBlazer7000TempEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry providing temperature information related to a specific temperature probe in the system." INDEX { lanBlazer7000TempIndex } ::= { lanBlazer7000TempTable 1 } LanBlazer7000TempEntry ::= SEQUENCE { lanBlazer7000TempIndex ResourceId, lanBlazer7000TempValue INTEGER, lanBlazer7000TempUpperLimit INTEGER, lanBlazer7000TempUpperWarning INTEGER, lanBlazer7000TempLowerWarning INTEGER, lanBlazer7000TempLowerLimit INTEGER } lanBlazer7000TempIndex OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "A unique index that identifies this temperature probe. This index corresponds to the lanBlazer7000ResourceIndex for temperature probe type resources." ::= { lanBlazer7000TempEntry 1 } lanBlazer7000TempValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current temperature reading of this temperature probe in degrees Celsius." ::= { lanBlazer7000TempEntry 2 } lanBlazer7000TempUpperLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The upper temperature limit of this temperature probe in degrees Celsius." ::= { lanBlazer7000TempEntry 3 } lanBlazer7000TempUpperWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The upper temperature warning of this temperature probe in degrees Celsius." ::= { lanBlazer7000TempEntry 4 } lanBlazer7000TempLowerWarning OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The lower temperature warning of this temperature probe in degrees Celsius." ::= { lanBlazer7000TempEntry 5 } lanBlazer7000TempLowerLimit OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The lower temperature limit of this temperature probe in degrees Celsius." ::= { lanBlazer7000TempEntry 6 } -- MODULE MANAGEMENT lanBlazer7000Modules OBJECT IDENTIFIER ::= { lanBlazer7000Chassis 5 } lanBlazer7000ModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000ModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of information related to the modules in the system." ::= { lanBlazer7000Modules 1 } lanBlazer7000ModuleEntry OBJECT-TYPE SYNTAX LanBlazer7000ModuleEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Attributes related to managing this module." INDEX { lanBlazer7000ModuleIndex } ::= { lanBlazer7000ModuleTable 1 } LanBlazer7000ModuleEntry ::= SEQUENCE { lanBlazer7000ModuleIndex ResourceId, lanBlazer7000ModuleName DisplayString, lanBlazer7000ModuleType INTEGER, lanBlazer7000ModuleBaseType INTEGER, lanBlazer7000ModuleSlotWidth INTEGER, lanBlazer7000ModuleSlotOffset INTEGER, lanBlazer7000ModulePorts INTEGER } lanBlazer7000ModuleIndex OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this module. This index corresponds to the lanBlazer7000ResourceIndex associated with module type resources." ::= { lanBlazer7000ModuleEntry 1 } lanBlazer7000ModuleName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A user-assignable name for this module." ::= { lanBlazer7000ModuleEntry 2 } lanBlazer7000ModuleType OBJECT-TYPE SYNTAX INTEGER { unknown(1), -- unknown module m5502-1000(2), -- 2 Port Gigabit m2206-1000(3), -- 6 Port Gigabit m5520-100TX-QS(4), -- 20 Port 10/100: Quality Phy's m5510-100FX(5), -- 10 Port Fast Ethernet Fiber m5500-SUP(6), -- Supervisor (5500) m5504-1000(7), -- 4 Port Gigabit m2201-1000(8), -- 1 Port Gigabit Option m5520-100TX-I(9), -- 20 Port 10/100: Intel Phy's m2202-100FX(10), -- 2 Port Fast Ethernet Fiber Option m5510R-100FX(11), -- 10 Port Routing Fast Ethernet Fiber m5512R-100TX(12), -- 12 Port Routing 10/100 m5500R-SUP(13), -- Routing Supervisor m5502R-1000(14), -- 2 Port Routing Gigabit m2200-SUP(15), -- Supervisor (2200) m2204-100TX(16), -- 4 Port 10/100 Option m2224-100TX(17) -- 24 Port 10/100 Option } ACCESS read-only STATUS mandatory DESCRIPTION "An enumerated integer that is unique for each module model. " ::= { lanBlazer7000ModuleEntry 3 } lanBlazer7000ModuleBaseType OBJECT-TYPE SYNTAX INTEGER { gigabit(1), -- Gigabit Ethernet Modules fastEthernet(2), -- Fast Ethernet Modules supervisor(3) -- Supervisor Modules } ACCESS read-only STATUS mandatory DESCRIPTION "The base type of this module. This object is used to describe the core functions of the module. Often, base designs are derived into multiple module types which are typically just packaging variations (e.g. changing the connector types). The value of this object corresponds to the value of lanBlazer7000ResourceBaseType." ::= { lanBlazer7000ModuleEntry 4 } lanBlazer7000ModuleSlotWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of slots that this module occupies." ::= { lanBlazer7000ModuleEntry 5 } lanBlazer7000ModuleSlotOffset OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The slot offset (one based) that identifies, along with the slot width and slot location, the actual slots that this module occupies. The offset identifies which slot within the width of the module that this module reports as its slot number." ::= { lanBlazer7000ModuleEntry 6 } lanBlazer7000ModulePorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of ports associated with this module." ::= { lanBlazer7000ModuleEntry 7 } -- PORT MANAGEMENT lanBlazer7000Ports OBJECT IDENTIFIER ::= { lanBlazer7000Chassis 6 } -- PORT MANAGEMENT DISCUSSION -- -- This section manages the physical ports within the system. -- -- There are attributes that are generic to the physical port class and every -- physical port in the system supports these attributes. These attributes are -- represented in the generic port management section. -- -- Note, however, that the following operations WILL EACH RESULT IN AN ERROR: -- Setting lanBlazer7000PortMode to disable(2) for an internal(1) port -- Setting lanBlazer7000PortName for an internal(1)) port -- -- Each type of port may also support other lanBlazer7000PortType-specific attributes. -- If a port supports a particular attribute, there is an instance of that port -- in the table that manages that attribute. These attributes are represented -- in the port tables that follow the generic port management section. -- -- internal(1) ports do not support any type-specific attributes. -- -- ether-ten-oneHundred(2) ports support: -- lanBlazer7000PortFlowControlMode -- lanBlazer7000PortDuplexMode -- lanBlazer7000PortSpeedMode -- lanBlazer7000PortAutoNegotiationMode -- lanBlazer7000PortAutoNegotiationSpeedAdvertisement -- lanBlazer7000PortAutoNegotiationDuplexAdvertisement -- lanBlazer7000PortRateLimitMode -- lanBlazer7000PortRateLimitRate -- lanBlazer7000PortRateLimitBurstSize -- lanBlazer7000PortPacePriorityMode -- -- ether-oneHundred(3) ports support: -- lanBlazer7000PortFlowControlMode -- lanBlazer7000PortDuplexMode -- lanBlazer7000PortRateLimitMode -- lanBlazer7000PortRateLimitRate -- lanBlazer7000PortRateLimitBurstSize -- lanBlazer7000PortPacePriorityMode -- -- ether-gigabit(4) ports (pre-standard) support: -- lanBlazer7000PortFlowControlMode -- (setting to enable-with-aggressive-backoff(3) RESULTS IN AN ERROR) -- lanBlazer7000PortPacePriorityMode -- GENERIC PORT MANAGEMENT lanBlazer7000PortMgt OBJECT IDENTIFIER ::= { lanBlazer7000Ports 1 } lanBlazer7000PortTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of information related to every data port in this data networking system." ::= { lanBlazer7000PortMgt 1 } lanBlazer7000PortEntry OBJECT-TYPE SYNTAX LanBlazer7000PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A data port associated with this data networking system." INDEX { lanBlazer7000PortIndex } ::= { lanBlazer7000PortTable 1 } LanBlazer7000PortEntry ::= SEQUENCE { lanBlazer7000PortIndex ResourceId, lanBlazer7000PortName DisplayString, lanBlazer7000PortType INTEGER, lanBlazer7000PortBaseType INTEGER, lanBlazer7000PortMode INTEGER, lanBlazer7000PortStatus INTEGER, lanBlazer7000PortConnector INTEGER, lanBlazer7000PortSpeedState INTEGER, lanBlazer7000PortDuplexState INTEGER, lanBlazer7000PortGroupBinding ResourceId } lanBlazer7000PortIndex OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this port. Typically, ports are child resources of the module that contains them. In these cases, ports are identified by their module and their relative physical position on that module." ::= { lanBlazer7000PortEntry 1 } lanBlazer7000PortName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-write STATUS mandatory DESCRIPTION "The user-assigned name for this port. Note that setting this object for an internal(1) port results in an error." ::= { lanBlazer7000PortEntry 2 } lanBlazer7000PortType OBJECT-TYPE SYNTAX INTEGER { internal(1), ether-ten-oneHundred(2), ether-oneHundred(3), ether-gigabit(4) } ACCESS read-only STATUS mandatory DESCRIPTION "An internal(1) port does not have an external connection. An ether-ten-oneHundred(2) port is an Ethernet port which can be switched between 10 and 100 megabits per second. An ether-oneHundred(3) port is a 100 megabits per second Fast Ethernet port. An ether-gigabit(4) port is a 1000 megabits per second Gigabit Ethernet port." ::= { lanBlazer7000PortEntry 3 } lanBlazer7000PortBaseType OBJECT-TYPE SYNTAX INTEGER { internal(1), ether-ten-oneHundred(2), ether-oneHundred(3), ether-gigabit(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The base type of this port. This object may be useful to help manage new port types that are similar in nature to legacy port types." ::= { lanBlazer7000PortEntry 4 } lanBlazer7000PortMode OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The mode of this port. When set to enable(1), this port passes data. When set to disable(2), the port does not receive or transmit data, nor does it generate port-level signaling e.g. link integrity pulses. Note that setting an internal(1) port to disable(2) results in an error." ::= { lanBlazer7000PortEntry 5 } lanBlazer7000PortStatus OBJECT-TYPE SYNTAX INTEGER { disabled(1), okay(2), warning(3), disabledButOkay(4), linkFailure(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of this port. Disabled(1) means that this port has been disabled through management action. Okay(2) indicates that this port is operating properly. Warning(3) indicates that this port is encountering an abnormal condition that, however, allows it to continue to pass data. LinkFailure(5) means that this port is unable to pass data." ::= { lanBlazer7000PortEntry 6 } lanBlazer7000PortConnector OBJECT-TYPE SYNTAX INTEGER { internal(1), rj45(2), fiber-ST(3), fiber-SC(4), rs-232(5), aui(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The connector type associated with this port." ::= { lanBlazer7000PortEntry 7 } lanBlazer7000PortSpeedState OBJECT-TYPE SYNTAX INTEGER { ten-megabits-per-second(1), one-hundred-megabits-per-second(2), one-gigabit-per-second(3), under-negotiation(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The data rate of this port in bits per second. For example, a standard Ethernet port (e.g. 10BASE-T) would indicate a value of ten-megabits-per-second((1) indicating that the port supports a data rate of 10Mb/s. For ports that can change their data rate (e.g. 10/100 ports), the value of this object indicates the current state of the port's speed capability." ::= { lanBlazer7000PortEntry 8 } lanBlazer7000PortDuplexState OBJECT-TYPE SYNTAX INTEGER { half-duplex(1), full-duplex(2), under-negotiation(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates whether this port is operating in full- or half-duplex mode. The value under-negotiation(3) indicates that the port has not selected an operational duplex setting yet." ::= { lanBlazer7000PortEntry 9 } lanBlazer7000PortGroupBinding OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "Each port is associated with a port group. Typically, a port will belong to a port group of one and the value of this object will be the same as the port index for this instance. That is, this port will point to itself. The intent of this object is to help manage ports that have hierarchical relationships. For example, an ATM port typically has a physical port and multiple logical ports (e.g. each logical port corresponding to an instance of an emulated LAN). In this case, each LANE instance would refer to the instance of the physical port associated with the ATM front-end. Another example is an FDDI DAS type port. In this case, there is a logical port associated with the FDDI switch port which is connected to the two FDDI physical port connectors. The physical FDDI ports both point to the logical instance of an FDDI port." ::= { lanBlazer7000PortEntry 10 } -- PORT FLOW CONTROL lanBlazer7000PortFlowControlMgt OBJECT IDENTIFIER ::= { lanBlazer7000Ports 2 } -- Flow Control -- -- Flow control is used by ports to slow down the incoming flow of data. It has been -- shown to be a very effective mechanism for improving network efficiency when used -- in conjunction with an end-station. lanBlazer7000PortFlowControlTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000PortFlowControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of ports that support flow control." ::= { lanBlazer7000PortFlowControlMgt 1 } lanBlazer7000PortFlowControlEntry OBJECT-TYPE SYNTAX LanBlazer7000PortFlowControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Configuration objects related to port based flow control." INDEX { lanBlazer7000PortIndex } ::= { lanBlazer7000PortFlowControlTable 1 } LanBlazer7000PortFlowControlEntry ::= SEQUENCE { lanBlazer7000PortFlowControlMode INTEGER } lanBlazer7000PortFlowControlMode OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), enable-with-aggressive-backoff(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Flow control is used to prevent or reduce the dropping of frames due to the lack of buffer space. Overall, networks are more efficient when a sending station is asked to pause in its sending process, rather than having the transmitted frames dropped. Flow control is not as efficient when used in conjunction with a shared ports, i.e. when used with a repeater. Therefore, flow control is not recommended for a port connected to shared topologies. Flow control is most effective when the port is directly connected to an end-station, especially when connected to a server. Flow control is recommended for ports connected directly to end-stations. When the port is in half-duplex mode, back pressure is used to control the incoming flow. Back pressure essentially forces collisions for short periods of time. When the port is in full-duplex mode, IEEE 802.3 standard pause frames are used to control the incoming flow. Note that setting an ether-gigabit(4) port to enable-with-aggressive-backoff(3) results in an error." ::= { lanBlazer7000PortFlowControlEntry 21 } -- DUPLEX MODE lanBlazer7000PortDuplexMgt OBJECT IDENTIFIER ::= { lanBlazer7000Ports 3 } -- A table that manages each port that supports the ability to switch -- between full- and half- duplex mode. lanBlazer7000PortDuplexTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000PortDuplexEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of ports that support full- and half-duplex data communications." ::= { lanBlazer7000PortDuplexMgt 1 } lanBlazer7000PortDuplexEntry OBJECT-TYPE SYNTAX LanBlazer7000PortDuplexEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A port device configuration that controls the duplex mode of this port." INDEX { lanBlazer7000PortIndex } ::= { lanBlazer7000PortDuplexTable 1 } LanBlazer7000PortDuplexEntry ::= SEQUENCE { lanBlazer7000PortDuplexMode INTEGER } lanBlazer7000PortDuplexMode OBJECT-TYPE SYNTAX INTEGER { half-duplex(1), full-duplex(2) } ACCESS read-write STATUS mandatory DESCRIPTION "A point-to-point Ethernet port may be configured to support half or full duplex communications. A full-duplex(2) port transmits and receives data concurrently, effectively doubling the data rate of the port. Half-duplex(1) ports transmit or receive data, but not at the same time. Half-duplex ports use CSMA/CD as the access method to the network. Ports that are connected to shared segments (i.e. connected to a repeater), should always be configured to be in half-duplex mode. This object indicates the desired duplexity of this port. If auto-negotiation is turned on for this port, then this value is ignored." ::= { lanBlazer7000PortDuplexEntry 31 } -- SPEED MODE -- The Speed Table manages the speed mode for ports that can switch speeds. lanBlazer7000PortSpeedMgt OBJECT IDENTIFIER ::= { lanBlazer7000Ports 4 } lanBlazer7000PortSpeedTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000PortSpeedEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of port devices that support multiple speeds." ::= { lanBlazer7000PortSpeedMgt 1 } lanBlazer7000PortSpeedEntry OBJECT-TYPE SYNTAX LanBlazer7000PortSpeedEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A port that supports multiple speeds." INDEX { lanBlazer7000PortIndex } ::= { lanBlazer7000PortSpeedTable 1 } LanBlazer7000PortSpeedEntry ::= SEQUENCE { lanBlazer7000PortSpeedMode INTEGER } lanBlazer7000PortSpeedMode OBJECT-TYPE SYNTAX INTEGER { ten-megabits-per-second(1), one-hundred-megabits-per-second(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Some of these values may not be applicable to certain types of ports. This object indicates the desired data rate of this port. If auto-negotiation is turned on for this port, then this value is ignored." ::= { lanBlazer7000PortSpeedEntry 41 } -- AUTO NEGOTIATION lanBlazer7000PortAutoNegotiationMgt OBJECT IDENTIFIER ::= { lanBlazer7000Ports 5 } lanBlazer7000PortAutoNegotiationTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000PortAutoNegotiationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of ports that support auto-negotiation." ::= { lanBlazer7000PortAutoNegotiationMgt 1 } lanBlazer7000PortAutoNegotiationEntry OBJECT-TYPE SYNTAX LanBlazer7000PortAutoNegotiationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Attributes associated with a port that supports auto-negotiation." INDEX { lanBlazer7000PortIndex } ::= { lanBlazer7000PortAutoNegotiationTable 1 } LanBlazer7000PortAutoNegotiationEntry ::= SEQUENCE { lanBlazer7000PortAutoNegotiationMode INTEGER, lanBlazer7000PortAutoNegotiationSpeedAdvertisement INTEGER, lanBlazer7000PortAutoNegotiationDuplexAdvertisement INTEGER } lanBlazer7000PortAutoNegotiationMode OBJECT-TYPE SYNTAX INTEGER { autoNegotiate(1), manualConfiguration(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this object to autoNegotiate(1) causes this port to negotiate the duplex mode and the port speed, subject to the port's capabilities." ::= { lanBlazer7000PortAutoNegotiationEntry 51 } lanBlazer7000PortAutoNegotiationSpeedAdvertisement OBJECT-TYPE SYNTAX INTEGER { ten-and-one-hundred-megabits-per-second(1), one-hundred-megabits-per-second(2), ten-megabits-per-second(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The speed to advertise while auto-negotiating." ::= { lanBlazer7000PortAutoNegotiationEntry 52 } lanBlazer7000PortAutoNegotiationDuplexAdvertisement OBJECT-TYPE SYNTAX INTEGER { full-and-half-duplex(1), half-duplex(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The duplexity to advertise while auto-negotiating." ::= { lanBlazer7000PortAutoNegotiationEntry 53 } -- RATE LIMITING lanBlazer7000PortRateLimitMgt OBJECT IDENTIFIER ::= { lanBlazer7000Ports 6 } -- Rate Limiting -- -- This table manages the rate limiting for ports that support this feature. Rate Limiting -- prevents floods from overwhelming a port (typically, a slower port). lanBlazer7000PortRateLimitTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000PortRateLimitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of ports that support the ability to limit the rate of floods." ::= { lanBlazer7000PortRateLimitMgt 1 } lanBlazer7000PortRateLimitEntry OBJECT-TYPE SYNTAX LanBlazer7000PortRateLimitEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The rate limit configuration associated with this port." INDEX { lanBlazer7000PortIndex } ::= { lanBlazer7000PortRateLimitTable 1 } LanBlazer7000PortRateLimitEntry ::= SEQUENCE { lanBlazer7000PortRateLimitMode INTEGER, lanBlazer7000PortRateLimitRate INTEGER, lanBlazer7000PortRateLimitBurstSize INTEGER } lanBlazer7000PortRateLimitMode OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), enableIncludeKnownMulticast(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object configures whether rate limiting is enabled for this port (the factory default is enable(1)). Enabling rate limiting for this port prevents floods from overwhelming the output buffer associated with this port. Normally, rate limiting will only consider frames that are flooded to this port. This typically does not include known multicasts. However, known multicasts can be included in the flood limiting by setting the value of this object to enableIncludeKnownMulticast(3)." ::= { lanBlazer7000PortRateLimitEntry 61 } lanBlazer7000PortRateLimitRate OBJECT-TYPE SYNTAX INTEGER { one-percent(1), two-percent(2), five-percent(3), ten-percent(4), twenty-percent(5), forty-percent(6), eighty-percent(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The percentage of the port's transmitted data allowed to be floods (or floods and known multicasts). For example, the factory default setting of twenty-percent(4) indicates that 20% of the data rate can be floods. For 10 Mb/s ports, this is equivalent to a maximum rate of approximately 3000 flooded pps; for 100 Mb/s ports, a maximum rate of approximately 30,000 flooded pps." ::= { lanBlazer7000PortRateLimitEntry 62 } lanBlazer7000PortRateLimitBurstSize OBJECT-TYPE SYNTAX INTEGER { rateLimit1(1), rateLimit2(2), rateLimit4(3), rateLimit8(4), rateLimit16(5), rateLimit32(6), rateLimit64(7), rateLimit128(8), rateLimit256(9), rateLimit1024(10), rateLimit2048(11) } ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of consecutive transmitted flooded (or flooded and known multicasted) packets. Typically, the burst size is set so as to not overflow the port's buffer." ::= { lanBlazer7000PortRateLimitEntry 63 } -- PACE PRIORITY lanBlazer7000PortPacePriorityMgt OBJECT IDENTIFIER ::= { lanBlazer7000Ports 7 } -- Pace Priority -- -- This table manages all ports that support classification of frame priority via -- 3Com's Pace(r) Prioritization. -- lanBlazer7000PortPacePriorityTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000PortPacePriorityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of ports that support the ability to classify frame priority based on 3Com Pace(r) Prioritization." ::= { lanBlazer7000PortPacePriorityMgt 1 } lanBlazer7000PortPacePriorityEntry OBJECT-TYPE SYNTAX LanBlazer7000PortPacePriorityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A port that supports 3Com Pace(r) priority." INDEX { lanBlazer7000PortIndex } ::= { lanBlazer7000PortPacePriorityTable 1 } LanBlazer7000PortPacePriorityEntry ::= SEQUENCE { lanBlazer7000PortPacePriorityMode INTEGER } lanBlazer7000PortPacePriorityMode OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When Pace priority is enabled, this port will detect frames that use 3Com Corporation's Pace(r) Priority signaling. Frames signaled with priority in this manner are mapped to traffic priority level 4 (on scale of 0-7)." ::= { lanBlazer7000PortPacePriorityEntry 71 } -- PORT CATEGORY lanBlazer7000PortCategoryMgt OBJECT IDENTIFIER ::= { lanBlazer7000Ports 8 } lanBlazer7000PortCategoryTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000PortCategoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of ports that support the port category feature. Currently, all ports support this capability." ::= { lanBlazer7000PortCategoryMgt 1 } lanBlazer7000PortCategoryEntry OBJECT-TYPE SYNTAX LanBlazer7000PortCategoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A port that supports port categorization." INDEX { lanBlazer7000PortIndex } ::= { lanBlazer7000PortCategoryTable 1 } LanBlazer7000PortCategoryEntry ::= SEQUENCE { lanBlazer7000PortCategoryMode INTEGER } lanBlazer7000PortCategoryMode OBJECT-TYPE SYNTAX INTEGER { userPort(1), servicePort(2) } ACCESS read-write STATUS mandatory DESCRIPTION "By default, all ports are considered service ports. A service port is a port that provides a networks service such as a connection to a server, other switches, or the like. A service port will trigger the service port event for status changes with the alarm severity and will trigger an alarm in the alarm table on link failure. In contrast, user ports trigger the user link event with warning severity. They do not trigger an alarm upon link failures. User ports are useful to prevent floods of traps or entries in the alarm table. This is especially true for ports connected to user hosts that power up in the morning and power down again at the end of the work day." ::= { lanBlazer7000PortCategoryEntry 81 } -- BUFFER MANAGEMENT -- -- This section is dedicated to managing any buffers that exist in the system. -- Buffers are used to store network traffic. They are indexed by the module -- that contains the buffer and a unique index within the buffer. lanBlazer7000BufferMgt OBJECT IDENTIFIER ::= { lanBlazer7000Chassis 7 } lanBlazer7000BufferTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000BufferEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of frame buffers in the system." ::= { lanBlazer7000BufferMgt 1 } lanBlazer7000BufferEntry OBJECT-TYPE SYNTAX LanBlazer7000BufferEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Objects related to the management of this frame buffer." INDEX { lanBlazer7000BufferIndex } ::= { lanBlazer7000BufferTable 1 } LanBlazer7000BufferEntry ::= SEQUENCE { lanBlazer7000BufferIndex ResourceId, lanBlazer7000BufferFabricPort ResourceId, lanBlazer7000BufferFabricPortDirection INTEGER, lanBlazer7000BufferSwitchPort ResourceId, lanBlazer7000BufferMemory INTEGER, lanBlazer7000BufferAgeTimer INTEGER, lanBlazer7000BufferPriorityServicing INTEGER, lanBlazer7000BufferPriorityAllocation INTEGER, lanBlazer7000BufferPriorityThreshold INTEGER, lanBlazer7000BufferCongestion INTEGER, lanBlazer7000BufferHighOverflowDrops Counter, lanBlazer7000BufferLowOverflowDrops Counter, lanBlazer7000BufferHighStaleDrops Counter, lanBlazer7000BufferLowStaleDrops Counter, lanBlazer7000BufferCongestionDrops Counter } lanBlazer7000BufferIndex OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "The unique index that identifies this buffer within the system. Buffers are indexed first by their module association and then a unique index within that module." ::= { lanBlazer7000BufferEntry 1 } lanBlazer7000BufferFabricPort OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "The switch fabric port associated with this buffer." ::= { lanBlazer7000BufferEntry 2 } lanBlazer7000BufferFabricPortDirection OBJECT-TYPE SYNTAX INTEGER { in(1), out(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates whether the buffer is used for buffering frames going into the switching fabric or coming out of the fabric." ::= { lanBlazer7000BufferEntry 3 } lanBlazer7000BufferSwitchPort OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "The switch port associated with this frame buffer. Some buffers are not associated with any one switch port. In those cases, the value of the resource ID returned will be the null resource ID." ::= { lanBlazer7000BufferEntry 4 } lanBlazer7000BufferMemory OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The amount of memory available for frame buffering in Kilobytes (KB)." ::= { lanBlazer7000BufferEntry 5 } lanBlazer7000BufferAgeTimer OBJECT-TYPE SYNTAX INTEGER { disable(1), quarter-second(2), one-second(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Configures the timer used for aging frames in this buffer. If the timer expires for a frame, the frame is dropped and the event is counted in the stale drop counter. By default, the age timer is set to a 0.25 seconds (quarter of a second). The actual time that a frame may be aged out may vary. When set to a quarter of a second (250ms), the actual time may vary between 160ms and 320ms. When set to a second (1000ms), the time may vary between 640ms and 1.28 seconds (1028ms)." ::= { lanBlazer7000BufferEntry 6 } lanBlazer7000BufferPriorityServicing OBJECT-TYPE SYNTAX INTEGER { strictPriority(1), everyTenThousand(2), everyThousand(3), everyHundred(4), everyFour(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object configures how often the normal priority queue is serviced relative to the high priority queue. By default, the normal priority queue is serviced every thousand frames(3). This means that the normal priority queue is guaranteed to be serviced after servicing, at most, one thousand high priority frames. It is important to service the normal priority queue for two reasons. One is to prevent starvation for frames on the normal priority queue. The other reason is that frames cannot be aged if they are not serviced (see the age timer)." ::= { lanBlazer7000BufferEntry 7 } lanBlazer7000BufferPriorityAllocation OBJECT-TYPE SYNTAX INTEGER { none(1), tenPercent(2), twentyPercent(3), thirtyPercent(4), fortyPercent(5), fiftyPercent(6) } ACCESS read-write STATUS mandatory DESCRIPTION "This object controls how much of the total buffer space should be allocated to high priority queue. Please be warned that setting this object to a different value causes the associated buffer to reset, causing a short loss of data. Setting the value of this object to none(1) not only allocates the entire buffer space to normal traffic, but also has the side effect of disabling the priority threshold. In other words, all traffic will be considered as normal priority traffic." ::= { lanBlazer7000BufferEntry 8 } lanBlazer7000BufferPriorityThreshold OBJECT-TYPE SYNTAX INTEGER { none(1), one(2), two(3), three(4), four(5), five(6), six(7), seven(8) } ACCESS read-write STATUS mandatory DESCRIPTION "This object configures the threshold for which frames are considered high priority. Frames may have a priority classification ranging from 0-7, 7 being the highest. By default, every frame that has priority 4 (four(5)) or above is considered a high priority frame and is buffered accordingly. If this buffer does not have any buffer space allocated for high priority frames, then the buffer threshold will be none(1). Setting this object to a different value without allocating buffer space to high priority traffic will result in an error." ::= { lanBlazer7000BufferEntry 9 } lanBlazer7000BufferCongestion OBJECT-TYPE SYNTAX INTEGER { informationNotAvailable(1), notCongested(2), congested(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates whether this buffer is in a congested state.." ::= { lanBlazer7000BufferEntry 10 } lanBlazer7000BufferHighOverflowDrops OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The count of the number of high priority frames dropped due to the high priority queue overflowing." ::= { lanBlazer7000BufferEntry 11 } lanBlazer7000BufferLowOverflowDrops OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The count of the number of low priority frames dropped due to the low priority queue overflowing." ::= { lanBlazer7000BufferEntry 12 } lanBlazer7000BufferHighStaleDrops OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The count of the number of high priority frames dropped due to being in the high priority queue too long (the frame aged out)." ::= { lanBlazer7000BufferEntry 13 } lanBlazer7000BufferLowStaleDrops OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The count of the number of low priority frames dropped due to being in the low priority queue too long (the frame aged out)." ::= { lanBlazer7000BufferEntry 14 } lanBlazer7000BufferCongestionDrops OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The count of the number of frames dropped due to the destination (output) buffer being congested. " ::= { lanBlazer7000BufferEntry 16 } -- SWITCHING lanBlazer7000Switching OBJECT IDENTIFIER ::= { odsLANBlazer7000Mib 5 } -- LAYER II SWITCHING lanBlazer7000SwitchingLayerII OBJECT IDENTIFIER ::= { lanBlazer7000Switching 1 } -- SWITCH MANAGEMENT lanBlazer7000SwitchGen OBJECT IDENTIFIER ::= { lanBlazer7000SwitchingLayerII 1 } lanBlazer7000SwitchSTPConfig OBJECT-TYPE SYNTAX INTEGER { ieee8021dStp(1), -- simple bridge stpPerVlan(2), -- virtual bridging twoLayerStp(3), -- separate planes disable(4) -- STP disabled } ACCESS read-write STATUS mandatory DESCRIPTION "When set to ieee8021dStp(1), the switch executes spanning tree conformant to the IEEE 802.1D bridging standard. The switch runs one instance of spanning tree. When set to stpPerVlan(2), the switch executes a separate instance of spanning tree for each virtual LAN. This configuration conforms to the model that instances of virtual LANs within the switch are separate virtual bridging functions. This method may not work well with bridge/routers that are also running spanning tree. When set to twoLayerStp(3), the switch executes a two-layer spanning tree to prevent loops. Two layer spanning tree creates a higher 'plane' of spanning tree between VLAN devices. This method of running spanning tree is 'plug and play' with bridge/router type devices and also scales better than the other two methods for large environments. When set to disable(4), spanning tree is disabled in the switch." ::= { lanBlazer7000SwitchGen 1 } lanBlazer7000SwitchAgingTime OBJECT-TYPE SYNTAX INTEGER (10..1000000) ACCESS read-write STATUS mandatory DESCRIPTION "The timeout period in seconds for aging dynamically learned forwarding information. A default of 300 seconds is recommended. An aged entry is marked invalid, but is not removed from the Address Forwarding Table, because it is assumed that it will be relearned to the same location within the table." ::= { lanBlazer7000SwitchGen 2 } lanBlazer7000SwitchSuperAgingTime OBJECT-TYPE SYNTAX INTEGER (1..30) ACCESS read-write STATUS mandatory DESCRIPTION "The timeout period in days for removing stale invalid entries from the Address Forwarding Table. A superaged entry is removed completely from the Address Forwarding Table, because it is assumed that the entry will never be relearned." ::= { lanBlazer7000SwitchGen 3 } -- LAYERII -- BRIDGE MANAGEMENT lanBlazer7000BridgeMgmt OBJECT IDENTIFIER ::= { lanBlazer7000SwitchingLayerII 2 } -- Bridge Table lanBlazer7000BridgeTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000BridgeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of Spanning Tree information for every bridge in the system." ::= { lanBlazer7000BridgeMgmt 1 } lanBlazer7000BridgeEntry OBJECT-TYPE SYNTAX LanBlazer7000BridgeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { lanBlazer7000BridgeIndex } ::= { lanBlazer7000BridgeTable 1 } LanBlazer7000BridgeEntry ::= SEQUENCE { lanBlazer7000BridgeIndex ResourceId, lanBlazer7000BridgeType INTEGER, lanBlazer7000BridgeMode INTEGER, lanBlazer7000BridgeStatus INTEGER, lanBlazer7000BridgeStpPriority INTEGER, lanBlazer7000BridgeStpTimeSinceTopologyChange TimeTicks, lanBlazer7000BridgeStpTopChanges Counter, lanBlazer7000BridgeStpDesignatedRoot BridgeId, lanBlazer7000BridgeStpRootCost INTEGER, lanBlazer7000BridgeStpRootPort INTEGER, lanBlazer7000BridgeStpMaxAge Timeout, lanBlazer7000BridgeStpHelloTime Timeout, lanBlazer7000BridgeStpHoldTime INTEGER, lanBlazer7000BridgeStpForwardDelay Timeout, lanBlazer7000BridgeStpBridgeMaxAge Timeout, lanBlazer7000BridgeStpBridgeHelloTime Timeout, lanBlazer7000BridgeStpBridgeForwardDelay Timeout } lanBlazer7000BridgeIndex OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this bridge." ::= { lanBlazer7000BridgeEntry 1 } lanBlazer7000BridgeType OBJECT-TYPE SYNTAX INTEGER { dot1d(1), virtual(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates whether this is a legacy dot1d bridge consisting of all switch ports or a virtual bridge consisting of all virtual subports for a particular Vlan." ::= { lanBlazer7000BridgeEntry 2 } lanBlazer7000BridgeMode OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Used to enable or disable Spanning Tree for this bridge. When set to disable(2), all BPDUs are forwarded like regular multicast packets. The default value is enable(1)." ::= { lanBlazer7000BridgeEntry 3 } lanBlazer7000BridgeStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The enable/disable status of this bridge. This object incorporates the setting of the lanBlazer7000SwitchSTPConfig object. When lanBlazer7000SwitchSTPConfig is set such that this bridge will not be active, lanBlazer7000BridgeStatus returns disabled(2). If lanBlazer7000SwitchSTPConfig is set such that this bridge will be active, and lanBlazer7000BridgeMode is enable(1), this object returns enabled(2)." ::= { lanBlazer7000BridgeEntry 4 } lanBlazer7000BridgeStpPriority OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The priority value of the Bridge Identifier. See dot1dStpPriority." ::= { lanBlazer7000BridgeEntry 5 } lanBlazer7000BridgeStpTimeSinceTopologyChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time since the last topology change was detected. See dot1dStpTimeSinceTopologyChange." ::= { lanBlazer7000BridgeEntry 6 } lanBlazer7000BridgeStpTopChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of topology changes. See dot1dStpTopChanges" ::= { lanBlazer7000BridgeEntry 7 } lanBlazer7000BridgeStpDesignatedRoot OBJECT-TYPE SYNTAX BridgeId ACCESS read-only STATUS mandatory DESCRIPTION "The bridge considered to be root by this node. See dot1dStpDesignatedRoot." ::= { lanBlazer7000BridgeEntry 8 } lanBlazer7000BridgeStpRootCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The cost of the path to the root from this node. See dot1dStpRootCost." ::= { lanBlazer7000BridgeEntry 9 } lanBlazer7000BridgeStpRootPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port number with the lowest cost path to the root bridge. See dot1dStpRootPort." ::= { lanBlazer7000BridgeEntry 10 } lanBlazer7000BridgeStpMaxAge OBJECT-TYPE SYNTAX Timeout ACCESS read-only STATUS mandatory DESCRIPTION "The maximum age used by this bridge to hold onto STP information before discarding. See dot1dStpMaxAge." ::= { lanBlazer7000BridgeEntry 11 } lanBlazer7000BridgeStpHelloTime OBJECT-TYPE SYNTAX Timeout ACCESS read-only STATUS mandatory DESCRIPTION "The amount of time between configuration BPDUs. See dot1dStpHelloTime." ::= { lanBlazer7000BridgeEntry 12 } lanBlazer7000BridgeStpHoldTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The time value that indicates the interval during which no more than two configuration BPDUs will be sent by this node. See dot1dStpHoldTime." ::= { lanBlazer7000BridgeEntry 13 } lanBlazer7000BridgeStpForwardDelay OBJECT-TYPE SYNTAX Timeout ACCESS read-only STATUS mandatory DESCRIPTION "The amount of time that this node stays in each of the Listening and Learning states. See dot1dStpForwardDelay." ::= { lanBlazer7000BridgeEntry 14 } lanBlazer7000BridgeStpBridgeMaxAge OBJECT-TYPE SYNTAX Timeout (600..4000) ACCESS read-write STATUS mandatory DESCRIPTION "The value of MaxAge when this bridge is the root. See dot1dStpBridgeMaxAge." ::= { lanBlazer7000BridgeEntry 15 } lanBlazer7000BridgeStpBridgeHelloTime OBJECT-TYPE SYNTAX Timeout (100..1000) ACCESS read-write STATUS mandatory DESCRIPTION "The value of HelloTime to use when this bridge is the root. See dot1dStpBridgeHelloTime." ::= { lanBlazer7000BridgeEntry 16 } lanBlazer7000BridgeStpBridgeForwardDelay OBJECT-TYPE SYNTAX Timeout (400..3000) ACCESS read-write STATUS mandatory DESCRIPTION "The value of FowardDelay to use when this bridge is the root. See dot1dStpBridgeForwardDelay." ::= { lanBlazer7000BridgeEntry 17 } -- Bridge Port Table lanBlazer7000BridgePortMgmt OBJECT IDENTIFIER ::= { lanBlazer7000SwitchingLayerII 3 } lanBlazer7000BridgePortTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000BridgePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION " A table of Spanning Tree information for every port that supports Spanning Tree in every bridge in the system " ::= { lanBlazer7000BridgePortMgmt 1 } lanBlazer7000BridgePortEntry OBJECT-TYPE SYNTAX LanBlazer7000BridgePortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { lanBlazer7000BridgePortIndex } ::= { lanBlazer7000BridgePortTable 1 } LanBlazer7000BridgePortEntry ::= SEQUENCE { lanBlazer7000BridgePortIndex ResourceId, lanBlazer7000BridgePortPriority INTEGER, lanBlazer7000BridgePortState INTEGER, lanBlazer7000BridgePortEnable INTEGER, lanBlazer7000BridgePortPathCost INTEGER, lanBlazer7000BridgePortDesignatedRoot BridgeId, lanBlazer7000BridgePortDesignatedCost INTEGER, lanBlazer7000BridgePortDesignatedBridge BridgeId, lanBlazer7000BridgePortDesignatedPort OCTET STRING, lanBlazer7000BridgePortForwardTransitions Counter, lanBlazer7000BridgePortFastStart INTEGER, lanBlazer7000BridgePortSetDefault INTEGER, lanBlazer7000BridgePortEnableChangeDetection INTEGER } lanBlazer7000BridgePortIndex OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this bridge port. This index corresponds to the lanBlazer7000ResourceIndex for bridge port type resources." ::= { lanBlazer7000BridgePortEntry 1 } lanBlazer7000BridgePortPriority OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The value of the priority field in the port ID. See dot1dStpPortPriority. The default value is 128." ::= { lanBlazer7000BridgePortEntry 2 } lanBlazer7000BridgePortState OBJECT-TYPE SYNTAX INTEGER { disabled(1), blocking(2), listening(3), learning(4), forwarding(5), broken(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The port's current state as defined by the Spanning Tree Protocol. See dot1dStpPortState. The virtual port is considered broken if its switch port is blocked." ::= { lanBlazer7000BridgePortEntry 3 } lanBlazer7000BridgePortEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The enabled/disabled status of this port. See dot1dStpPortEnable. The default is enabled(2)." ::= { lanBlazer7000BridgePortEntry 4 } lanBlazer7000BridgePortPathCost OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The contribution of this port to the path cost of the paths towards the spanning tree root. See dot1dStpPortPathCost. The default value is dependent on the port speed, trunking mode, and duplexity." ::= { lanBlazer7000BridgePortEntry 5 } lanBlazer7000BridgePortDesignatedRoot OBJECT-TYPE SYNTAX BridgeId ACCESS read-only STATUS mandatory DESCRIPTION "The bridge recorded as root for this port's segment. See dot1dStpPortDesignatedRoot." ::= { lanBlazer7000BridgePortEntry 6 } lanBlazer7000BridgePortDesignatedCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The path cost of the designated root of the segment connected to this port. See dot1dStpPortDesignatedCost." ::= { lanBlazer7000BridgePortEntry 7 } lanBlazer7000BridgePortDesignatedBridge OBJECT-TYPE SYNTAX BridgeId ACCESS read-only STATUS mandatory DESCRIPTION "The bridge identifier of the bridge that is considered the designated bridge for this port's segment. See dot1dStpPortDesignatedBridge." ::= { lanBlazer7000BridgePortEntry 8 } lanBlazer7000BridgePortDesignatedPort OBJECT-TYPE SYNTAX OCTET STRING (SIZE (2)) ACCESS read-only STATUS mandatory DESCRIPTION "The port identifier of the port on the Designated Bridge for this port's segment. See dot1dStpPortDesignatedPort." ::= { lanBlazer7000BridgePortEntry 9 } lanBlazer7000BridgePortForwardTransitions OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times this port has transitioned from the learning state to the forwarding state. See dot1dStpPortForwardTransitions." ::= { lanBlazer7000BridgePortEntry 10 } lanBlazer7000BridgePortFastStart OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS deprecated DESCRIPTION "This object is being replaced by the switch port object lanBlazer7000SwitchPortFastStart. When this bridge port object is set to enable(1), the bridge port and all other bridge ports on the same switch port, transition right from blocking to forwarding, skipping the listening and learning states. When this bridge port object is set to disable(2), the bridge port and all other bridge ports on the same switch port have this option disabled. The user should be warned that using the fast start feature greatly increases the likelihood of unintended network loops that would otherwise be prevented by participating in the normal spanning tree algorithm. The factory default value for this object is disable(2)." ::= { lanBlazer7000BridgePortEntry 11 } lanBlazer7000BridgePortSetDefault OBJECT-TYPE SYNTAX INTEGER { useCurrentValues(1), setDefault(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When set to setDefault(2), the lanBlazer7000BridgePortPriority, lanBlazer7000BridgePortEnable, and lanBlazer7000BridgePortPathCost will be set to the factory default values." ::= { lanBlazer7000BridgePortEntry 12 } lanBlazer7000BridgePortEnableChangeDetection OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this object is set to enable(1), a Topology Change Notification will be generated when this port goes to Blocking or Forwarding (if the port is a designated port). When set to disable(2), no Topology Change Notification will be generated for this port. The default is enable(1)." ::= { lanBlazer7000BridgePortEntry 13 } -- ADDRESS MANAGEMENT lanBlazer7000L2AddrMgmt OBJECT IDENTIFIER ::= { lanBlazer7000SwitchingLayerII 4 } -- Address Database lanBlazer7000L2AddrDatabaseMgt OBJECT IDENTIFIER ::= { lanBlazer7000L2AddrMgmt 1 } -- Address Database -- -- The address table provides data that would normally be available from the standard -- bridge MIB. The standard bridge MIB has a few short comings, however. -- -- 1. It is indexed by MACAddress, forcing the bridge to sort a table that is normally -- hashed. When the address table is quite large, this sorting can become quite a drag on -- the processor. -- -- 2. The bridge MIB address table does not extend well to devices that support virtual -- LANs. -- -- 3. There are other objects that are desirable to be managed that the standard MIB does -- not support. -- -- This address database is indexed by address entry index. Each address entry has the -- traditional layer II MAC Address and port binding for that address, as well as some -- other value added fields such as address priority. -- -- Each address entry is logically contained by a separate address filtering table (AFT). -- Separate address tables are important to the support of Virtual LANs (VLANs). For -- frames that are explicitly bound to a VLAN either by explicit tagging or by source -- port association (port-based VLANs), separate AFTs enable a host to -- appear on different VLANs with different port bindings. Also, for frames that are -- implicitly bound to VLANs based on protocol type and/or host address, separate -- AFTs enable layer III VLANs for client systems. -- -- In the case where the AFT is supporting a VLAN with a host or host, protocol policy, -- the VLAN index indicated is the VLAN classification for that host or host, protocol -- combination. -- -- Note, it is the default to create separate AFTs for each VLAN and for each protocol -- type. In some cases, this may not be desirable and in these cases, multiple VLANs -- and/or protocols may point to the same AFTs. lanBlazer7000L2AddressTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000L2AddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of address table entries. The address table is used by the bridging function to perform forwarding and filtering decisions. An address may appear multiple times in different entries corresponding to the different logical address tables." ::= { lanBlazer7000L2AddrDatabaseMgt 1 } lanBlazer7000L2AddressEntry OBJECT-TYPE SYNTAX LanBlazer7000L2AddressEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A particular address table entry." INDEX { lanBlazer7000L2AddressIndex } ::= { lanBlazer7000L2AddressTable 1 } LanBlazer7000L2AddressEntry ::= SEQUENCE { lanBlazer7000L2AddressIndex INTEGER, lanBlazer7000L2AddressTableIndex INTEGER, lanBlazer7000L2AddressMacAddress MacAddress, lanBlazer7000L2AddressPortBinding ResourceId, lanBlazer7000L2AddressBindingValid INTEGER, lanBlazer7000L2AddressVlanID INTEGER, lanBlazer7000L2AddressPriority INTEGER, lanBlazer7000L2AddressForward INTEGER, lanBlazer7000L2AddressCopy INTEGER, lanBlazer7000L2AddressPersistence INTEGER, lanBlazer7000L2AddressStatus INTEGER } lanBlazer7000L2AddressIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this address entry." ::= { lanBlazer7000L2AddressEntry 1 } lanBlazer7000L2AddressTableIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The address table that this entry is associated with." ::= { lanBlazer7000L2AddressEntry 2 } lanBlazer7000L2AddressMacAddress OBJECT-TYPE SYNTAX MacAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IEEE 802 MAC Address associated with this database entry." ::= { lanBlazer7000L2AddressEntry 3 } lanBlazer7000L2AddressPortBinding OBJECT-TYPE SYNTAX ResourceId ACCESS read-write STATUS mandatory DESCRIPTION "The switch port that this address is associated with. " ::= { lanBlazer7000L2AddressEntry 4 } lanBlazer7000L2AddressBindingValid OBJECT-TYPE SYNTAX INTEGER { valid(1), invalid(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The port binding of an address entry is aged out in conformance with the specifications laid out in the IEEE 802.1D standard. When the address is aged out, the port binding becomes invalid." ::= { lanBlazer7000L2AddressEntry 5 } lanBlazer7000L2AddressVlanID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The VLAN ID of the VLAN that this address entry corresponds to." ::= { lanBlazer7000L2AddressEntry 6 } lanBlazer7000L2AddressPriority OBJECT-TYPE SYNTAX INTEGER { priorityZero(1), priorityFour(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If set to high(2), frames destined to this address are classified with priority value 4." ::= { lanBlazer7000L2AddressEntry 7 } lanBlazer7000L2AddressForward OBJECT-TYPE SYNTAX INTEGER { normalForward(1), specialDelivery(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When set to specialDelivery(2), frames sent to this address are treated to special delivery where the spanning tree state of the inbound port is ignored. Typically, special delivery is only used for Bridge PDUs such as spanning tree frames." ::= { lanBlazer7000L2AddressEntry 8 } lanBlazer7000L2AddressCopy OBJECT-TYPE SYNTAX INTEGER { normalForward(1), copyCPU(2) } ACCESS read-only STATUS mandatory DESCRIPTION "It is sometimes useful for the switch processor to eavesdrop on traffic to certain destinations. This is especially useful in supporting the intelligent multicasting function." ::= { lanBlazer7000L2AddressEntry 9 } lanBlazer7000L2AddressPersistence OBJECT-TYPE SYNTAX INTEGER { other(1), invalid(2), permanent(3), deleteOnReset(4), deleteOnTimeout(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This object indicates the persistence of this entry: other(1) - This entry is currently in use but the conditions under which it will remain so are different from each of the following values. invalid(2) - Writing this value to the object removes the corresponding entry. permanent(3) - Address is not aged out. Additionally, if the address is seen as a source on a different port for this VLAN, the frame is filtered and the filter event is counted. Static address entries are stored in non-volatile memory and are restored to the address table following each system reset. deleteOnReset(4) - Indicates that the entry is not aged out, however the entry is not stored in non-volatile memory. Therefore, when the device is reset, the entry will not be restored. deleteOnTimeout(5) - Typically, address entries are learned dynamically by the switch. These entries are aged out of the table if they are not active on the network. This value correlates to this state." ::= { lanBlazer7000L2AddressEntry 10 } lanBlazer7000L2AddressStatus OBJECT-TYPE SYNTAX INTEGER { other(1), learned(2), self(3), mgmt(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the entry: other(1) - None of the following. learned(2) - This entry was learned dynamically. self(3) - The value of the corresponding instance of lanBlazer7000AddressMacAddress represents one of the bridge's addresses. mgmt(4) - This entry was added or modified by management. Entries that have been added by management and made permanent" ::= { lanBlazer7000L2AddressEntry 11 } -- Address Summary Table lanBlazer7000L2AddrSummaryMgt OBJECT IDENTIFIER ::= { lanBlazer7000L2AddrMgmt 2 } lanBlazer7000L2AddrSummaryTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000L2AddrSummaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This summary table packs the address entries in the address database into summary objects. The goal is to optimize the upload of the large amount of data stored therein. Typically, a management station would use getNext requests to retrieve the next logical summary object. The returned object value contains the next n entries of the address database packed into one PDU. The instance of the object returned is the index of the last address entry packed in the summary, thereby optimizing for the next getNext request. [ Fix this? What about gets?] " ::= { lanBlazer7000L2AddrSummaryMgt 1 } lanBlazer7000L2AddrSummaryEntry OBJECT-TYPE SYNTAX LanBlazer7000L2AddrSummaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A summary object that packs as many address entries possible into a summary object." INDEX { lanBlazer7000L2AddressIndex } ::= { lanBlazer7000L2AddrSummaryTable 1 } LanBlazer7000L2AddrSummaryEntry ::= SEQUENCE { lanBlazer7000L2AddrSummary OCTET STRING } lanBlazer7000L2AddrSummary OBJECT-TYPE SYNTAX OCTET STRING (SIZE(20..4096)) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object is a packed opaque structure representing an array of address entries. The format of this structure is: struct L2AddressEntry { UNS32 index; UNS8 addr[6]; // mac address UNS8 fabricPort; //fabricPort and subPort == lanBlazer7000L2AddressPortBinding UNS8 subPort; UNS16 vlanID, //the global vlan id UNS8 portBindingValidFlag; UNS8 addressForwardFlag; UNS8 addressCopyFlag; UNS8 addressPersistence; UNS8 addressStatus; }; struct L2AddressSummary{ UNS8 numberOfEntries; // Number of entries that follow UNS8 version; // version == 1 UNS16 endianFlag; L2AddressEntry entryArray[numberOfEntries]; };" ::= { lanBlazer7000L2AddrSummaryEntry 1 } -- Address Control lanBlazer7000L2AddrControlMgt OBJECT IDENTIFIER ::= { lanBlazer7000L2AddrMgmt 3 } lanBlazer7000L2AddressControlTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000L2AddressControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table provides the network manager the ability to create new, static address entries. Entries added through this table are added to the specified address table as a static entry and are save in non-volatile memory for reconfiguration upon system restart. This table is indexed by the lanBlazer7000AgentMgrIndex value which provides a separate instance for each manager." ::= { lanBlazer7000L2AddrControlMgt 1 } lanBlazer7000L2AddressControlEntry OBJECT-TYPE SYNTAX LanBlazer7000L2AddressControlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A control entry enables this manager to add a new entry to the specified address table. When the entry is written to, the control index value is reset to 0. When the actual entry is created, the index value will read as non-zero, reporting the actual entry created." INDEX { lanBlazer7000AgentMgrIndex } ::= { lanBlazer7000L2AddressControlTable 1 } LanBlazer7000L2AddressControlEntry ::= SEQUENCE { lanBlazer7000L2AddressControlIndex INTEGER, lanBlazer7000L2AddressControlMacAddress MacAddress, lanBlazer7000L2AddressControlPortBinding ResourceId, lanBlazer7000L2AddressControlVlanID INTEGER, lanBlazer7000L2AddressControlPriority INTEGER, lanBlazer7000L2AddressControlPersistence INTEGER, lanBlazer7000L2AddressControlStatus INTEGER } lanBlazer7000L2AddressControlIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the address entry that was created for this address." ::= { lanBlazer7000L2AddressControlEntry 1 } lanBlazer7000L2AddressControlMacAddress OBJECT-TYPE SYNTAX MacAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IEEE 802 MAC Address associated with this database entry." ::= { lanBlazer7000L2AddressControlEntry 2 } lanBlazer7000L2AddressControlPortBinding OBJECT-TYPE SYNTAX ResourceId ACCESS read-write STATUS mandatory DESCRIPTION "The port to bind this address to." ::= { lanBlazer7000L2AddressControlEntry 3 } lanBlazer7000L2AddressControlVlanID OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The VLAN ID of the VLAN to bind this address to." ::= { lanBlazer7000L2AddressControlEntry 4 } lanBlazer7000L2AddressControlPriority OBJECT-TYPE SYNTAX INTEGER { priorityZero(1), priorityFour(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If set to high(2), frames destined to this address are classified with priority value 4." ::= { lanBlazer7000L2AddressControlEntry 5 } lanBlazer7000L2AddressControlPersistence OBJECT-TYPE SYNTAX INTEGER { permanent(1), deleteOnReset(2), deleteOnTimeout(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The persistence of the entry to be created: permanent(1) - Address is not aged out. Additionally, if the address is seen as a source on a different port for this VLAN, the frame is filtered and the filter event is counted. Static address entries are stored in non-volatile memory and are restored to the address table following each system reset. deleteOnReset(2) - Indicates that the entry is not to be aged, however the entry is not stored in non-volatile memory. Therefore, when the device is reset, the entry will not be restored. deleteOnTimeout(3) - Indicates that the entry is to be aged by the normal aging process." ::= { lanBlazer7000L2AddressControlEntry 6 } lanBlazer7000L2AddressControlStatus OBJECT-TYPE SYNTAX INTEGER { createRequest(1), underCreation(2), success(3), otherError(4), entryExistsError(5), invalidMacAddress(6), invalidPortBinding(7), invalidVlanID(8) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of an entry to be created. When adding an entry all fields will be set, and then the control status is set to createRequest(1), indicating that the entry is to be created. During creation, the status will be underCreation(2). If the creation is successful, then the status will be set to success(3), and the value of lanBlazer7000AddressControlIndex indicates the index of the entry that was created in the address table. Otherwise if the creation was not successful, then one of the following error codes will be set and the entry will not be created: otherError(4) - An error other then the others defined. entryExistsError(5) - An entry already exists with this MAC address in this address table. invalidMacAddress(6) - Cannot create an entry with this MAC address. invalidTableIndex(7) - The table does not exist. invalidPortBinding(8) - The port binding is invalid. invalidVlanID(9) - The VLAN ID is invalid. Note that the only value that is valid to write to this object is createRequest(1), and that this object will never return the value createRequest(1)." ::= { lanBlazer7000L2AddressControlEntry 7 } -- Address Change lanBlazer7000L2AddrChangeMgt OBJECT IDENTIFIER ::= { lanBlazer7000L2AddrMgmt 4 } -- Address Change Information lanBlazer7000L2AddressChangeLast OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index of the last entry written to the address change table" ::= { lanBlazer7000L2AddrChangeMgt 1 } lanBlazer7000L2AddressChangeWraps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The count of the number of times the address change table has wrapped." ::= { lanBlazer7000L2AddrChangeMgt 2 } lanBlazer7000L2AddressChangeMaxEntries OBJECT-TYPE SYNTAX INTEGER (1024..4096) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of entries in the address change table." ::= { lanBlazer7000L2AddrChangeMgt 3 } -- Address Change Tables -- -- Address Change Tables -- lanBlazer7000L2AddressChangeTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000L2AddressChangeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "." ::= { lanBlazer7000L2AddrChangeMgt 4 } lanBlazer7000L2AddressChangeEntry OBJECT-TYPE SYNTAX LanBlazer7000L2AddressChangeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The address change table provides a quick way of getting only the entries that have recently changed. Since entries age out as part of the normal switching process, entries that have aged (i.e. their destination bindings are no longer valid) are not considered to be changed. Any other modification to the entry, including deletion or creation, are considered to be changes. The address change table is considered a circular table. When an entry changes, it is added to the next position within the table. If the 'next' position goes beyond the end of the table, the 'next' position is set to the beginning of the table (1) and the wrap counter (lanBlazer7000AddressChangeWraps) is incremented. The lanBlazer7000AddressChangeLast value is updated with the index of the last entered entry. An entry may be in the table multiple times if it has changed multiple times. Every time that an entry changes, it is added to the change table. A network management application should follow the following algorithm when polling this table: 1. Set lastChangeWrap = lanBlazer7000AddressChangeWraps. 2. Set lastChangeIndex = lanBlazer7000AddressChangeLast 3. Get the entire lanBlazer7000AddressEntryTable. 4. Submit a getNext for ., updating lastChangeWrap and lastChangeIndex with the returned next values. Update the address entry database with the changed values. 5. Repeat step 4 until no more entries are returned. 6. Wait polling timeout period. 7. Get wrap events counter and last index. If the wrap events counter is equal to lastChangeWrap, then goto step 4. Else if the wrap events counter is more then one greater then lastChangeWrap, goto step 1. Else the wrap events counter is exactly one greater then lastChangeWrap, and if the last index is greater then lastChangeIndex, then goto step 1, else goto step 4. The last step simply insures that we have not missed any of the change entries. Essentially it says that if we have wrapped to beyond where we last polled, then we must get the entire table to synch up again. Otherwise we can just get the entries that have changed." INDEX { lanBlazer7000L2AddressChangeWrapCount, lanBlazer7000L2AddressChangeIndex } ::= { lanBlazer7000L2AddressChangeTable 1 } LanBlazer7000L2AddressChangeEntry ::= SEQUENCE { lanBlazer7000L2AddressChangeWrapCount INTEGER, lanBlazer7000L2AddressChangeIndex INTEGER, lanBlazer7000L2AddressChangeIndexChanged INTEGER, lanBlazer7000L2AddressChangeSummary OCTET STRING } lanBlazer7000L2AddressChangeWrapCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of times that the lanBlazer7000AddressChangeLastIndex had wrapped when this entry was added." ::= { lanBlazer7000L2AddressChangeEntry 1 } lanBlazer7000L2AddressChangeIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index that uniquely identifies this address change entry." ::= { lanBlazer7000L2AddressChangeEntry 2 } lanBlazer7000L2AddressChangeIndexChanged OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The address entry that changed. The value of this object corresponds to the lanBlazer7000L2AddressIndex object. " ::= { lanBlazer7000L2AddressChangeEntry 3 } lanBlazer7000L2AddressChangeSummary OBJECT-TYPE SYNTAX OCTET STRING (SIZE(20)) ACCESS read-only STATUS mandatory DESCRIPTION " The structure is interpreted in the following manner:" ::= { lanBlazer7000L2AddressChangeEntry 4 } -- SWITCH PORT MANAGEMENT lanBlazer7000SwitchPortMgt OBJECT IDENTIFIER ::= { lanBlazer7000Switching 2 } -- Switch Port Table -- -- The switch port table manages the configuration and status of each -- switch port. lanBlazer7000SwitchPortTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000SwitchPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { lanBlazer7000SwitchPortMgt 1 } lanBlazer7000SwitchPortEntry OBJECT-TYPE SYNTAX LanBlazer7000SwitchPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { lanBlazer7000SwitchPortIndex } ::= { lanBlazer7000SwitchPortTable 1 } LanBlazer7000SwitchPortEntry ::= SEQUENCE { lanBlazer7000SwitchPortIndex ResourceId, lanBlazer7000SwitchPortSTAPMode INTEGER, lanBlazer7000SwitchPortConvertToStatic INTEGER, lanBlazer7000SwitchPortLearningMode INTEGER, lanBlazer7000SwitchPortHuntGroup INTEGER, lanBlazer7000SwitchPortPhysicalPort ResourceId, lanBlazer7000SwitchPortKnownMode INTEGER, lanBlazer7000SwitchPortMappingMethod INTEGER, lanBlazer7000SwitchPortTrunkingMode INTEGER, lanBlazer7000SwitchPortVlanBindingMethod INTEGER, lanBlazer7000SwitchPortIgnoreTag INTEGER, lanBlazer7000SwitchPortVlanID INTEGER, lanBlazer7000SwitchPort3ComMappingTableIndex INTEGER, lanBlazer7000SwitchPortAutoVlanCreation INTEGER, lanBlazer7000SwitchPortIfIndex INTEGER, lanBlazer7000SwitchPortFastStart INTEGER, lanBlazer7000SwitchPortVlanExchange INTEGER } lanBlazer7000SwitchPortIndex OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "A unique index that identifies this switch port. The value of this index corresponds to the value of the lanBlazer7000ResourceIndex for switch ports." ::= { lanBlazer7000SwitchPortEntry 1 } lanBlazer7000SwitchPortSTAPMode OBJECT-TYPE SYNTAX INTEGER { enable(1), -- default disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Disabling spanning tree on a switch port prevents the switch port from participating in the spanning tree process. When disabled(2), this port will neither generate BPDUs, nor process received BPDUs. Also, the port will always start in the forwarding state. A port configured in this mode will not be able to detect network loops involving this port. The factory default is to enable spanning tree on all ports." ::= { lanBlazer7000SwitchPortEntry 2 } lanBlazer7000SwitchPortConvertToStatic OBJECT-TYPE SYNTAX INTEGER { learnAsDynamic(1), convertToStatic(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this object is set to convertToStatic(2), all addresses learned on this port will be added to the non-volatile version of the static address table. Typically, this object will be used to perform a crude form of address database update where the address activity associated with this port is collected as static (i.e. permanent) addresses while the value of this object is set to convertToStatic(2). Following this usually short period of time (perhaps a week of activity), the value of this object is restored back to its default value of learnAsDynamic(1) and learning for this port is disabled. It is important that the user verify the address database to verify that only the desired addresses were made permanent." ::= { lanBlazer7000SwitchPortEntry 3 } lanBlazer7000SwitchPortLearningMode OBJECT-TYPE SYNTAX INTEGER { enable(1), -- default disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Disable learning on a bridge port to prevent new addresses from being added to the address database. Used in combination with static (permanent) address entries, disabling address learning is an effective security feature to prevent new hosts from appearing on the network, or to prevent hosts from moving to different locations in the network. The default is enable." ::= { lanBlazer7000SwitchPortEntry 4 } lanBlazer7000SwitchPortHuntGroup OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hunt groups provide the capability to logically bind multiple switch ports into one switch port. This provides a way of balancing the load of multiple links between like-configured switches. Care must be taken to configure the hunt groups properly to prevent accidental network looping. Use this object to bind this port to a specific hunt group. When not configured to a specific hunt group, set the value of this object to zero." ::= { lanBlazer7000SwitchPortEntry 5 } lanBlazer7000SwitchPortPhysicalPort OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "The physical port resource bound to this switch port." ::= { lanBlazer7000SwitchPortEntry 6 } lanBlazer7000SwitchPortKnownMode OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enabling known mode for this switch port causes the port to safely discard frames flooded because they are unknown unicast frames. This mode greatly enhances the efficiency of the port's output buffer since space is not wasted for frames not meant for this port. Enabling this feature disables learning for this port. Addresses associated for this port should be entered statically. The default is disable." ::= { lanBlazer7000SwitchPortEntry 7 } lanBlazer7000SwitchPortMappingMethod OBJECT-TYPE SYNTAX INTEGER { port-based(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The frame mapping method of this switch port. When set to port-based(1) (the factory default), all non-tagged frames are classified to the VLAN associated with this switch port." ::= { lanBlazer7000SwitchPortEntry 8 } lanBlazer7000SwitchPortTrunkingMode OBJECT-TYPE SYNTAX INTEGER { clear(1), -- Factory Default ieee8021q(2), -- IEEE 802.1Q Format multiLevel(3), -- Multi-level Format trunk3Com(4) -- 3Com Trunking Format } ACCESS read-write STATUS mandatory DESCRIPTION "The trunking mode of this port. All frames transmitted out this switch port are translated to the appropriate trunking format: Clear: Ethernet or IEEE 802.3 frame format. This is the default. IEEE 802.1Q: The original frame with a new Ethernet Type (Protocol = 0xXXXX) and the VLAN ID inserted following the original Source Address. Also, the CRC is recalculated. Multi-level: The original frame is encapsulated in an IEEE 802.3 legal frame proprietary to a major networking equipment vendor. 3Com LinkSwitch: The original frame has the VLAN ID added to the front of the frame (before the Destination Address). Trunking format is proprietary to 3Com Corporation." ::= { lanBlazer7000SwitchPortEntry 9 } lanBlazer7000SwitchPortVlanBindingMethod OBJECT-TYPE SYNTAX INTEGER { static(1), persistent(2), dynamic(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The VLAN binding method of a switch port specifies the way in which the port can be a member of the egress lists of VLANs other than the port default VLAN specified by lanBlazer7000SwitchPortVlanID: static: A Virtual Switch Port must be statically created for each VLAN/port combination. persistent: A Virtual Switch Port is automatically created for each VLAN known to the switch (i.e., the port is a member of the egress lists of all VLANs). dynamic: A Virtual Switch Port is automatically created for each VLAN when the associated VLAN ID is used as a tag in an IEEE 802.1Q or Multi-level tagged frame received on the port (i.e., the port is a member of the egress lists of the VLANs from frames received on the port). The default is static." ::= { lanBlazer7000SwitchPortEntry 10 } lanBlazer7000SwitchPortIgnoreTag OBJECT-TYPE SYNTAX INTEGER { useTag(1), -- default ignoreTag(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Each switch port is capable of ignoring the VLAN Tag associated with a frame in a trunking format. When ignored, the tag is used as the default in the event that a VLAN classification based on the switch's policy(s) cannot be made. This feature is useful for connecting layer 2 VLANs and layer 3 VLANs. The default is useTag." ::= { lanBlazer7000SwitchPortEntry 11 } lanBlazer7000SwitchPortVlanID OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "When this switch port is configured in port-based VLAN mode, all non-tagged frames received on this port are bound to this VLAN. Otherwise, non-tagged frames are classified to this VLAN as the default if a VLAN binding cannot be otherwise determined. The factory default is 1, which is the VLAN ID of the Default VLAN." ::= { lanBlazer7000SwitchPortEntry 12 } lanBlazer7000SwitchPort3ComMappingTableIndex OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The 3Com VLAN mapping table associated with this switch port. The default is 1, which indicates the default mapping table." ::= { lanBlazer7000SwitchPortEntry 13 } lanBlazer7000SwitchPortAutoVlanCreation OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enabling auto VLAN creation for this switch port causes the port to dynamically create a VLAN whenever an IEEE 802.1Q or Multi-level tagged frame is received on the port with a tag value which does not correspond to a known VLAN. All switch ports with a trunking mode of IEEE 802.1Q or Multi-level are bound to this created VLAN. The default is disable." ::= { lanBlazer7000SwitchPortEntry 14 } lanBlazer7000SwitchPortMirrorMode OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When set to enable(1), this object indicates that the port is defined as a mirror port through the lanBlazer7000PortMirroringTable. A mirror port duplicates frames received at one or more source ports." ::= { lanBlazer7000SwitchPortEntry 15 } lanBlazer7000SwitchPortIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Each switch port is associated with an interface. This object provides a mechanism to map switch ports to bridge ports." ::= { lanBlazer7000SwitchPortEntry 16 } lanBlazer7000SwitchPortFastStart OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this object is set to enable(1), bridge ports on this switch port transitions right from blocking to forwarding, skipping the listening and learning states. The user should be warned that using the fast start feature greatly increases the likelihood of unintended network loops that would otherwise be prevented by participating in the normal spanning tree algorithm. The factory default value for this object is disable(2)." ::= { lanBlazer7000SwitchPortEntry 17 } lanBlazer7000SwitchPortVlanExchange OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this object is set to enable(1), this switch port attempts to learn VLANs from a major networking equipment vendor if the switch port's trunking mode is IEEE 802.1Q Format or Multi-level Format. The factory default value for this object is enable(1)." ::= { lanBlazer7000SwitchPortEntry 18 } -- HUNT GROUPS lanBlazer7000HuntGroupMgt OBJECT IDENTIFIER ::= { lanBlazer7000Switching 4 } -- A hunt group logically binds together multiple switch ports so that they act as one -- switch port. This feature enables the ports within the hunt group to load -- share the network traffic. -- -- The hunt group feature is targeted for a restricted topology where two switches -- are connected together by multiple lines of the same bandwidth. Hunt groups -- require that both switches be configured identically to the other. -- -- Each hunt group requires a base port. The hunt group assumes the characteristics -- of the base port where all the managed information (configuration & statistics) of -- any of the switch ports in the hunt group is only available from the base port -- instance. lanBlazer7000HuntGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000HuntGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { lanBlazer7000HuntGroupMgt 1 } lanBlazer7000HuntGroupEntry OBJECT-TYPE SYNTAX LanBlazer7000HuntGroupEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { lanBlazer7000HuntGroupIndex } ::= { lanBlazer7000HuntGroupTable 1 } LanBlazer7000HuntGroupEntry ::= SEQUENCE { lanBlazer7000HuntGroupIndex INTEGER, lanBlazer7000HuntGroupName DisplayString, lanBlazer7000HuntGroupBasePort ResourceId, lanBlazer7000HuntGroupNumberOfPorts INTEGER, lanBlazer7000HuntGroupLoadSharing INTEGER, lanBlazer7000HuntGroupStatus INTEGER } lanBlazer7000HuntGroupIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this hunt group. This index corresponds to the value of lanBlazer7000ResourceIndex for resources of the hunt group type." ::= { lanBlazer7000HuntGroupEntry 1 } lanBlazer7000HuntGroupName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { lanBlazer7000HuntGroupEntry 2 } lanBlazer7000HuntGroupBasePort OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "The switch port index that serves as the base port for this hunt group. Each hunt group requires a base port. In lieu of a specific configuration, the hunt group will inherit the first switch port bound to the hunt group as its base port. The base port serves as the management focus for the hunt group. That is, a hunt group is managed as one switch port whose instance is provided by the base switch port. All configuration (e.g. spanning tree information) and statistics related to switch ports are meaningful only through the instance of the base port." ::= { lanBlazer7000HuntGroupEntry 3 } lanBlazer7000HuntGroupNumberOfPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current number of ports that belong to this hunt group." ::= { lanBlazer7000HuntGroupEntry 4 } lanBlazer7000HuntGroupLoadSharing OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { lanBlazer7000HuntGroupEntry 5 } lanBlazer7000HuntGroupStatus OBJECT-TYPE SYNTAX INTEGER { createRequest(1), underCreation(2), deleteRequest(3), active(4) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { lanBlazer7000HuntGroupEntry 6 } -- Port Mirroring lanBlazer7000PortMirroringMgt OBJECT IDENTIFIER ::= { lanBlazer7000Switching 5 } -- Port Mirroring is used to duplicate packets received on one or more ports on -- another port so that the mirror port can be monitored, for example with an -- RMON probe. Port Mirroring allows either all packets received on the source -- port, or a periodic sample, to be duplicated on the mirror port. lanBlazer7000PortMirroringTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000PortMirroringEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of port mirroring entries used to mirror traffic from a source port to a mirror port." ::= { lanBlazer7000PortMirroringMgt 1 } lanBlazer7000PortMirroringEntry OBJECT-TYPE SYNTAX LanBlazer7000PortMirroringEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Objects related to the PortMirroring functionality." INDEX { lanBlazer7000PortMirroringIndex } ::= { lanBlazer7000PortMirroringTable 1 } LanBlazer7000PortMirroringEntry ::= SEQUENCE { lanBlazer7000PortMirroringIndex ResourceId, lanBlazer7000PortMirroringSourceSubPort INTEGER, lanBlazer7000PortMirroringSamplerType INTEGER, lanBlazer7000PortMirroringRate INTEGER, lanBlazer7000PortMirroringMirrorPort ResourceId } lanBlazer7000PortMirroringIndex OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "The unique index that identifies this entry. This index consists of a switch fabric port and the index of a Packet Lookup Engine servicing this fabric port." ::= { lanBlazer7000PortMirroringEntry 1 } lanBlazer7000PortMirroringSourceSubPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The frame sampler source switch subport. The source port is the port from which received traffic will be mirrored. This object identifies the switch subport only, the switch fabric port is identified in lanBlazer7000PortMirroringIndex. If set to 0, all subports associated with the lanBlazer7000PortMirroringIndex will be source ports. The default value is 0." ::= { lanBlazer7000PortMirroringEntry 2 } lanBlazer7000PortMirroringSamplerType OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2), periodic(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The type for this frame sampler. When set to enable(1), every frame received on the source port(s) will be mirrored at the mirror port. When set to disable(2), no frames received on the source port(s) will be mirrored at the mirror port. When set to periodic(3), frames will be mirrored at the rate defined in lanBlazer7000PortMirroringRate. The default value is disable(2)." ::= { lanBlazer7000PortMirroringEntry 3 } lanBlazer7000PortMirroringRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Used in conjunction with lanBlazer7000PortMirroringSamplerType to implement periodic sampling functionality. If lanBlazer7000PortMirroringSamplerType is set to periodic(3), this object defines the number of packets/second that will be mirrored. If lanBlazer7000PortMirroringSamplerType is not periodic(3), this object will set to 0." ::= { lanBlazer7000PortMirroringEntry 4 } lanBlazer7000PortMirroringMirrorPort OBJECT-TYPE SYNTAX ResourceId ACCESS read-write STATUS mandatory DESCRIPTION "The Switch Port on which frames received at source ports(s) will be duplicated. If no mirror port has been defined this object will return NULL." ::= { lanBlazer7000PortMirroringEntry 5 } -- VIRTUAL LANS lanBlazer7000VlanMgt OBJECT IDENTIFIER ::= { odsLANBlazer7000Mib 7 } -- VIRTUAL LAN TABLE lanBlazer7000Vlans OBJECT IDENTIFIER ::= { lanBlazer7000VlanMgt 1 } -- Each entry in this table identifies a virtual LAN. lanBlazer7000VlanTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000VlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { lanBlazer7000Vlans 1 } lanBlazer7000VlanEntry OBJECT-TYPE SYNTAX LanBlazer7000VlanEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { lanBlazer7000VlanID } ::= { lanBlazer7000VlanTable 1 } LanBlazer7000VlanEntry ::= SEQUENCE { lanBlazer7000VlanID INTEGER, lanBlazer7000VlanName DisplayString, lanBlazer7000VlanIfIndex INTEGER, lanBlazer7000VlanAFTIndex INTEGER, lanBlazer7000VlanBridgeIndex ResourceId, lanBlazer7000VlanStatus INTEGER, lanBlazer7000VlanInitialHashTableSize INTEGER, lanBlazer7000VlanAutoIncrementHTSize INTEGER, lanBlazer7000VlanLearnStatus INTEGER } lanBlazer7000VlanID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An identifier that is unique within the administrative domain. This ID is assigned by the management application and is meaningful within that context. This ID is used to identify VLANs when tagged using either the IEEE 802.1 frame format or the Multi-level frame format." ::= { lanBlazer7000VlanEntry 1 } lanBlazer7000VlanName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A user-assignable name for this Vlan." ::= { lanBlazer7000VlanEntry 2 } lanBlazer7000VlanIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Each virtual LAN has a virtual interface associated with it. This enables RMON monitoring to occur per-VLAN. It also provides a handy mechanism to map virtual LANs to bridge ports by mapping them with the ifStack table from the Interface MIB." ::= { lanBlazer7000VlanEntry 3 } lanBlazer7000VlanAFTIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The address table used for this VLAN for explicitly tagged frames (frames received in a trunking frame format or from a port in port-based VLAN mode.) Normally, each VLAN maps to a unique address table. This is useful for environments with duplicate host addresses appear on different VLANs on different ports. For those environments where duplicate hosts on different VLANs don't exist, or exist but are on the same port, and where the address table size and/or aging is a concern, then multiple VLANs may be mapped to the same address table." ::= { lanBlazer7000VlanEntry 4 } lanBlazer7000VlanBridgeIndex OBJECT-TYPE SYNTAX ResourceId ACCESS read-write STATUS mandatory DESCRIPTION "The bridge resource which is bound to this Vlan." ::= { lanBlazer7000VlanEntry 5 } lanBlazer7000VlanStatus OBJECT-TYPE SYNTAX INTEGER { createRequest(1), underCreation(2), destroyRequest(3), underDestruction(4), active(5), otherError(6), entryExistsError(7), invalidVlanID(8), invalidVlanName(9), invalidVlanAFTIndex(10), invalidVlanBridgeIndex(11), invalidVlanInitialHashTableSize(12), invalidVlanAutoIncrementHTSize(13) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of an entry to be created or deleted. When adding an entry all fields will be set, and then the status is set to createRequest(1) (indicating that the entry is to be created). When deleting an entry the status is set to destroyRequest(3) (indicating that the entry is to be destroyed). During creation the status will be underCreation(2). If the creation is successful, then the status will be set to active(5). Otherwise if the creation was not successful then one of the following error codes will be set and the entry will not be created: otherError(6) - An error other than the others defined. entryExistsError(7) - An entry already exists. invalidVlanID(8) - the VLAN ID is invalid. invalidVlanName(9) - the VLAN name is invalid. invalidVlanAFTIndex(10) - the VLAN AFT index is invalid. invalidVlanBridgeIndex(11) - the VLAN bridge index is invalid. invalidVlanInitialHashTableSize(12) - the VLAN initial hash table size is invalid. invalidVlanAutoIncrementHTSize(13) - the VLAN auto increment hash table size is invalid." ::= { lanBlazer7000VlanEntry 6 } lanBlazer7000VlanInitialHashTableSize OBJECT-TYPE SYNTAX INTEGER (16..8192) ACCESS read-write STATUS mandatory DESCRIPTION "The initial hash table size used for MAC addresses on this VLAN. This attribute may only be set when lanBlazer7000VlanStatus is set to createRequest(1). It must be a power of 2 between 16 and 8192, inclusive." ::= { lanBlazer7000VlanEntry 7 } lanBlazer7000VlanAutoIncrementHTSize OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether or not the hash table size used for MAC addresses on this VLAN is automatically increased as necessary to hold more MAC addresses. This attribute may only be set when lanBlazer7000VlanStatus is set to createRequest(1)." ::= { lanBlazer7000VlanEntry 8 } lanBlazer7000VlanLearnStatus OBJECT-TYPE SYNTAX INTEGER { notLearned(1), vlanExchange(2), auto(3) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates if the VLAN was learned. If learned it indicates if the VLAN was learned either by VLAN Exchange or Auto VLAN creation." ::= { lanBlazer7000VlanEntry 9 } -- 3COM MAPPING TABLES lanBlazer7000VlanMappings OBJECT IDENTIFIER ::= { lanBlazer7000VlanMgt 3 } -- 3Com Map Table Identification lanBlazer70003ComMapping OBJECT IDENTIFIER ::= { lanBlazer7000VlanMappings 1 } lanBlazer70003ComMappingTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer70003ComMappingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { lanBlazer70003ComMapping 1 } lanBlazer70003ComMappingEntry OBJECT-TYPE SYNTAX LanBlazer70003ComMappingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { lanBlazer70003ComMappingTableIndex } ::= { lanBlazer70003ComMappingTable 1 } LanBlazer70003ComMappingEntry ::= SEQUENCE { lanBlazer70003ComMappingTableIndex INTEGER, lanBlazer70003ComMappingTableName DisplayString, lanBlazer70003ComMappingTableStatus INTEGER } lanBlazer70003ComMappingTableIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { lanBlazer70003ComMappingEntry 1 } lanBlazer70003ComMappingTableName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..31)) ACCESS read-write STATUS mandatory DESCRIPTION "A user-readable name associated with this table." ::= { lanBlazer70003ComMappingEntry 2 } lanBlazer70003ComMappingTableStatus OBJECT-TYPE SYNTAX INTEGER { createRequest(1), destroyRequest(2), active(3), entryExistsError(4), otherError(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of an entry to be created. When adding an entry all fields will be set, and then the status is set to createRequest(1), indicating that the entry is to be created. If the creation is successful, then the status will be set to active(3). Otherwise if the creation was not successful then one of the following error codes will be set and the entry will not be created: entryExistsError(4) - An entry already exists. otherError(5) - An error other than the others defined." ::= { lanBlazer70003ComMappingEntry 3 } -- 3Com VLAN Mappings lanBlazer7000Vlan3ComMapping OBJECT IDENTIFIER ::= { lanBlazer7000VlanMappings 2 } lanBlazer7000Vlan3ComMappingTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000Vlan3ComMappingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { lanBlazer7000Vlan3ComMapping 1 } lanBlazer7000Vlan3ComMappingEntry OBJECT-TYPE SYNTAX LanBlazer7000Vlan3ComMappingEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { lanBlazer70003ComMappingTableIndex, lanBlazer7000Vlan3ComMappingIndex } ::= { lanBlazer7000Vlan3ComMappingTable 1 } LanBlazer7000Vlan3ComMappingEntry ::= SEQUENCE { lanBlazer7000Vlan3ComMappingIndex INTEGER, lanBlazer7000Vlan3ComMappingVlanID INTEGER, lanBlazer7000Vlan3ComMappingStatus INTEGER } lanBlazer7000Vlan3ComMappingIndex OBJECT-TYPE SYNTAX INTEGER (1..16) ACCESS read-only STATUS mandatory DESCRIPTION "The external tag of this 3Com VLAN." ::= { lanBlazer7000Vlan3ComMappingEntry 1 } lanBlazer7000Vlan3ComMappingVlanID OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The VLAN ID of the VLAN that this 3Com tag is associated with." ::= { lanBlazer7000Vlan3ComMappingEntry 2 } lanBlazer7000Vlan3ComMappingStatus OBJECT-TYPE SYNTAX INTEGER { createRequest(1), destroyRequest(2), active(3), otherError(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of an entry to be created. When adding an entry all fields will be set, and then the status is set to createRequest(1), indicating that the entry is to be created. If the creation is successful, then the status will be set to active(3). Otherwise if the creation was not successful then one of the following error codes will be set and the entry will not be created: otherError(4) - An error other than the others defined." ::= { lanBlazer7000Vlan3ComMappingEntry 3 } -- VIRTUAL SWITCH PORTS lanBlazer7000VirtualPorts OBJECT IDENTIFIER ::= { lanBlazer7000VlanMgt 4 } lanBlazer7000VirtualSwitchPortTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000VirtualSwitchPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { lanBlazer7000VirtualPorts 1 } lanBlazer7000VirtualSwitchPortEntry OBJECT-TYPE SYNTAX LanBlazer7000VirtualSwitchPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An instance of a virtual switch port indicates that this switch port is a member of this VLAN." INDEX { lanBlazer7000VirtualSwitchPortIndex } ::= { lanBlazer7000VirtualSwitchPortTable 1 } LanBlazer7000VirtualSwitchPortEntry ::= SEQUENCE { lanBlazer7000VirtualSwitchPortIndex ResourceId, lanBlazer7000VirtualSwitchPortFormat INTEGER, lanBlazer7000VirtualSwitchPortBridgePort ResourceId, lanBlazer7000VirtualSwitchPortBindingType INTEGER, lanBlazer7000VirtualSwitchPortStatus INTEGER } lanBlazer7000VirtualSwitchPortIndex OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "The Resource ID of the virtual switch port bound to the VLAN." ::= { lanBlazer7000VirtualSwitchPortEntry 1 } lanBlazer7000VirtualSwitchPortFormat OBJECT-TYPE SYNTAX INTEGER { clear(1), -- don't tag for this VLAN, port trunkingFormat(2) -- use switch port format - may be clear } ACCESS read-write STATUS mandatory DESCRIPTION "Typically, a VLAN capable switch port has one of three modes: access, trunk, or hybrid. In access mode, the port sends frames in clear format (untagged). In trunk mode, all outbound frames are translated into the switch port's configured trunking format. In hybrid mode, it is possible for a port to send trunked frames for some VLANs and clear frames for others. In this case, the switch port is configured to trunk, and the virtual switch port(s) for those VLANs that require clear formatted frames are configured to be override the switch port setting. This is done by setting this object to clear(1). By default, the value of this object is trunkingFormat(2) which means to use the trunking format configured for this switch port. (which may be clear)." ::= { lanBlazer7000VirtualSwitchPortEntry 2 } lanBlazer7000VirtualSwitchPortBridgePort OBJECT-TYPE SYNTAX ResourceId ACCESS read-write STATUS mandatory DESCRIPTION "The bridge port resource bound to this virtual port." ::= { lanBlazer7000VirtualSwitchPortEntry 3 } lanBlazer7000VirtualSwitchPortBindingType OBJECT-TYPE SYNTAX INTEGER { static(1), -- port binding was manually created persistent(2), -- port binding was automatically created dynamic(3) -- port binding was automatically created } ACCESS read-only STATUS mandatory DESCRIPTION "The method by which this switch port was bound to the VLAN. If the value is static(1), the binding was manually created by the administrator. If the value is persistent(2), the binding was created by the switch because the VLAN is the port-based VLAN for the switch port, or the switch port VLAN Binding Method is persistent. These bindings may not be removed. If the value is dynamic(3), the binding was created by the switch as a result of receiving a tagged frame on the switch port with a VLAN ID corresponding to the VLAN." ::= { lanBlazer7000VirtualSwitchPortEntry 4 } lanBlazer7000VirtualSwitchPortStatus OBJECT-TYPE SYNTAX INTEGER { createRequest(1), destroyRequest(2), active(3), otherError(4), entryExistsError(5), entryNoExistError(6) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of an entry to be created or deleted. When adding an entry all fields will be set, and then the status is set to createRequest(1) (indicating that the entry is to be created). When deleting an entry the status is set to destroyRequest(2) (indicating that the entry is to be destroyed). If the creation is successful, then the status will be set to active(3). Otherwise if the creation was not successful then one of the following error codes will be set and the entry will not be created: otherError(4) - An error other than the others defined. entryExistsError(5) - On creation, an entry already exists. On deletion, the entry may not be removed. entryNoExistError(6) - The VLAN specified by ID does not exist." ::= { lanBlazer7000VirtualSwitchPortEntry 5 } -- EVENT MANAGEMENT lanBlazer7000Events OBJECT IDENTIFIER ::= { odsLANBlazer7000Mib 10 } -- EVENT TABLE lanBlazer7000EventMgt OBJECT IDENTIFIER ::= { lanBlazer7000Events 1 } -- Event Table lanBlazer7000EventTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000EventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of events currently supported." ::= { lanBlazer7000EventMgt 1 } lanBlazer7000EventEntry OBJECT-TYPE SYNTAX LanBlazer7000EventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Attributes associated with the event." INDEX { lanBlazer7000EventIndex } ::= { lanBlazer7000EventTable 1 } LanBlazer7000EventEntry ::= SEQUENCE { lanBlazer7000EventIndex INTEGER, lanBlazer7000EventMode INTEGER, lanBlazer7000EventLogAction INTEGER, lanBlazer7000EventTrapAction INTEGER, lanBlazer7000EventConsoleAction INTEGER } lanBlazer7000EventIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { lanBlazer7000EventEntry 1 } lanBlazer7000EventMode OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Disabling an event prevents this event from taking any actions when triggered. When set to enable to the console, the event will print the event information to the console serial port. The user can select whether to view log messages, trap messages or any event at the console." ::= { lanBlazer7000EventEntry 2 } -- -- lanBlazer7000EventCategory has been removed -- lanBlazer7000EventLogAction OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, this action will cause an event log entry to be created." ::= { lanBlazer7000EventEntry 3 } lanBlazer7000EventTrapAction OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, this event will cause an SNMP trap to be generated." ::= { lanBlazer7000EventEntry 4 } lanBlazer7000EventConsoleAction OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, this event will cause a message to printed to the console serial port." ::= { lanBlazer7000EventEntry 5 } -- EVENT LOG lanBlazer7000EventLogMgt OBJECT IDENTIFIER ::= { lanBlazer7000Events 2 } -- EVENT LOG OBJECTS lanBlazer7000LogTableMaxSize OBJECT-TYPE SYNTAX INTEGER (0..2048) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of entries in the log table. Changing this value causes the existing log to be truncated and rebuilt." ::= { lanBlazer7000EventLogMgt 1 } lanBlazer7000LogLastEntry OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The log index of the last entry entered in the log." ::= { lanBlazer7000EventLogMgt 2 } lanBlazer7000LogWraps OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times that the last entry has wrapped from 65K back to 1." ::= { lanBlazer7000EventLogMgt 3 } -- EVENT LOG TABLE lanBlazer7000EventLog OBJECT IDENTIFIER ::= { lanBlazer7000Events 3 } lanBlazer7000EventLogTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000EventLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The log table for the events in the event table that are enabled for the Log Action." ::= { lanBlazer7000EventLog 1 } lanBlazer7000EventLogEntry OBJECT-TYPE SYNTAX LanBlazer7000EventLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the log indicates information associated with a particular event." INDEX { lanBlazer7000EventLogIndex } ::= { lanBlazer7000EventLogTable 1 } LanBlazer7000EventLogEntry ::= SEQUENCE { lanBlazer7000EventLogEventIndex INTEGER, lanBlazer7000EventLogIndex INTEGER, lanBlazer7000EventLogTime TimeTicks, lanBlazer7000EventLogDescr DisplayString, lanBlazer7000EventLogType EventCategory, lanBlazer7000EventLogSeverity INTEGER, lanBlazer7000EventLogDTM DisplayString, lanBlazer7000EventLogResType ResourceType, lanBlazer7000EventLogResID ResourceId, lanBlazer7000EventLogResLeaf INTEGER, lanBlazer7000EventLogValueType EventValueType, lanBlazer7000EventLogValue OCTET STRING, lanBlazer7000EventLogEpochTime INTEGER, lanBlazer7000EventLogID INTEGER } lanBlazer7000EventLogEventIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index that uniquely identifies the event that caused this log entry." ::= { lanBlazer7000EventLogEntry 1 } lanBlazer7000EventLogIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this log entry." ::= { lanBlazer7000EventLogEntry 2 } lanBlazer7000EventLogTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when this event was triggered." ::= { lanBlazer7000EventLogEntry 3 } lanBlazer7000EventLogDescr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The event log description." ::= { lanBlazer7000EventLogEntry 4 } lanBlazer7000EventLogType OBJECT-TYPE SYNTAX EventCategory ACCESS read-only STATUS mandatory DESCRIPTION "The type of event that caused this log entry." ::= { lanBlazer7000EventLogEntry 5 } lanBlazer7000EventLogSeverity OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "The severity associated with this event. It is recommended that the severity be interpreted in the following manner: 0-19: Normal 20-39: Informational 40-59: Warning 60-79: Alarm 80-99: Severe Error 100: Failure." ::= { lanBlazer7000EventLogEntry 6 } lanBlazer7000EventLogDTM OBJECT-TYPE SYNTAX DisplayString (SIZE (18)) ACCESS read-only STATUS mandatory DESCRIPTION "The date and time when this log entry was made. The format is yy-Mon- dd hh:mm:ss, time is in 24 hour time." ::= { lanBlazer7000EventLogEntry 7 } lanBlazer7000EventLogResType OBJECT-TYPE SYNTAX ResourceType ACCESS read-only STATUS mandatory DESCRIPTION "The type of object (if provided) that triggered this event. If not provided, the value is equal to 'Invalid Resource'." ::= { lanBlazer7000EventLogEntry 8 } lanBlazer7000EventLogResID OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "The instance of this resource (if provided - see lanBlazer7000EventLogResType) that triggered this event." ::= { lanBlazer7000EventLogEntry 9 } lanBlazer7000EventLogResLeaf OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A number corresponding to the attribute associated with this resource and this event entry. It corresponds exactly to the leaf MIB number of the MIB that manages this resource. For example, if a port's mode changed, the configuration event log entry would indicate the value of 5 which is the leaf index of the lanBlazer7000PortMode within the lanBlazer7000PortTable MIB table." ::= { lanBlazer7000EventLogEntry 10 } lanBlazer7000EventLogValueType OBJECT-TYPE SYNTAX EventValueType ACCESS read-only STATUS mandatory DESCRIPTION "The data type associated with the log event value. This object indicates how to interpret the data stored in the event log value: - none(1) indicates no value returned. - integer32(2) - a 4 byte unsigned integer. - integer64(3) - an 8 byte unsigned integer. - displayString(4) - a null terminated (or up to 8 characters) string. - ipv4NetworkAddress(5) - a 4 byte IP version 4 network address. - ieee802MACAddress(6) - a 6 byte MAC Address. - timeticks(7) - sysUpTime type value (4 bytes)" ::= { lanBlazer7000EventLogEntry 11 } lanBlazer7000EventLogValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The value associated with the event encoded in an octet string. Refer to lanBlazer7000EventLogValueType for how to interpret this value. The value encoded in this string is in Big Endian order." ::= { lanBlazer7000EventLogEntry 12 } lanBlazer7000EventLogEpochTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of time ticks since the epoch when this event was logged. The interpretation of this value is as follows: struct DateTimeOvly { UNS32 year:6; UNS32 month:4; UNS32 day:5; UNS32 hour:5; UNS32 minute:6; UNS32 second:6; }; The epoch is January 1, 1997, at 00:00:00. A value of 0 refers to this date and time. " ::= { lanBlazer7000EventLogEntry 13 } lanBlazer7000EventLogID OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique index that identifies the occurence of this event. This ID can be correlated between traps, logs and the like." ::= { lanBlazer7000EventLogEntry 14 } -- SHUTDOWN EVENT LOG lanBlazer7000ShutdownLogMgt OBJECT IDENTIFIER ::= { lanBlazer7000Events 4 } -- The most recent event log entries are stored in non-volatile memory. In the event -- of a system restart, it may be useful to look at the last few events that were -- logged before the system last went down. The Shutdown Log Table stores those -- last events. -- -- SHUTDOWN EVENT LOG OBJECTS lanBlazer7000ShutdownLogTableMaxSize OBJECT-TYPE SYNTAX INTEGER (0..128) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of entries in the non-volatile log table. Changing the value of this object changes the maximum number of entries to be stored in Shutdown." ::= { lanBlazer7000ShutdownLogMgt 1 } lanBlazer7000ShutdownLogLastEntry OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The ID of the last entry made to the shutdown log." ::= { lanBlazer7000ShutdownLogMgt 2 } lanBlazer7000ShutdownLogAcknowledged OBJECT-TYPE SYNTAX INTEGER { not-acknowledged(1), acknowledged(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This object is to set to acknowledged(2) the first time the Shutdown Log Table is accessed indicating that the Shutdown log has been read (at least once) since the system restarted." ::= { lanBlazer7000ShutdownLogMgt 3 } -- SHUTDOWN LOG TABLE -- -- The Shutdown Log Table is a copy of the log file stored in non-volatile memory. It is copied -- to dynamic memory (RAM) when the system is initialized and the non-volatile version -- is re-initialized. lanBlazer7000EventShutdownLog OBJECT IDENTIFIER ::= { lanBlazer7000Events 5 } lanBlazer7000EventShutdownLogTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000EventShutdownLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of the last events logged before the system restarted." ::= { lanBlazer7000EventShutdownLog 1 } lanBlazer7000EventShutdownLogEntry OBJECT-TYPE SYNTAX LanBlazer7000EventShutdownLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A log entry stored in non-volatile memory." INDEX { lanBlazer7000EventShutdownLogIndex } ::= { lanBlazer7000EventShutdownLogTable 1 } LanBlazer7000EventShutdownLogEntry ::= SEQUENCE { lanBlazer7000EventShutdownLogEventIndex INTEGER, lanBlazer7000EventShutdownLogIndex INTEGER, lanBlazer7000EventShutdownLogTime TimeTicks, lanBlazer7000EventShutdownLogDescr DisplayString, lanBlazer7000EventShutdownLogType EventCategory, lanBlazer7000EventShutdownLogSeverity INTEGER, lanBlazer7000EventShutdownLogDTM DisplayString, lanBlazer7000EventShutdownLogResType ResourceType, lanBlazer7000EventShutdownLogResID ResourceId, lanBlazer7000EventShutdownLogResLeaf INTEGER, lanBlazer7000EventShutdownLogValueType EventValueType, lanBlazer7000EventShutdownLogValue OCTET STRING, lanBlazer7000EventShutdownLogEpochTime INTEGER, lanBlazer7000EventShutdownLogID INTEGER } lanBlazer7000EventShutdownLogEventIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index that uniquely identifies the event that caused this ShutdownLog entry." ::= { lanBlazer7000EventShutdownLogEntry 1 } lanBlazer7000EventShutdownLogIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "An index that uniquely identifies this ShutdownLog entry." ::= { lanBlazer7000EventShutdownLogEntry 2 } lanBlazer7000EventShutdownLogTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when this event was triggered. Note, the value corresponds to the sysUpTime when the system was last running (i.e. before it was shutdown.)" ::= { lanBlazer7000EventShutdownLogEntry 3 } lanBlazer7000EventShutdownLogDescr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The event ShutdownLog description." ::= { lanBlazer7000EventShutdownLogEntry 4 } lanBlazer7000EventShutdownLogType OBJECT-TYPE SYNTAX EventCategory ACCESS read-only STATUS mandatory DESCRIPTION "The type of event that caused this ShutdownLog entry." ::= { lanBlazer7000EventShutdownLogEntry 5 } lanBlazer7000EventShutdownLogSeverity OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "The severity associated with this event. It is recommended that the severity be interpreted in the following manner: 0-19: Normal 20-39: Informational 40-59: Warning 60-79: Alarm 80-99: Severe Error 100: Failure." ::= { lanBlazer7000EventShutdownLogEntry 6 } lanBlazer7000EventShutdownLogDTM OBJECT-TYPE SYNTAX DisplayString (SIZE (18)) ACCESS read-only STATUS mandatory DESCRIPTION "The date and time when this ShutdownLog entry was made. The format is yy-Mon-dd hh:mm:ss, time is in 24 hour time." ::= { lanBlazer7000EventShutdownLogEntry 7 } lanBlazer7000EventShutdownLogResType OBJECT-TYPE SYNTAX ResourceType ACCESS read-only STATUS mandatory DESCRIPTION "The type of object (if provided) that triggered this event. If not provided, the value is invalid." ::= { lanBlazer7000EventShutdownLogEntry 8 } lanBlazer7000EventShutdownLogResID OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "The instance of this resource (if provided) that triggered this event." ::= { lanBlazer7000EventShutdownLogEntry 9 } lanBlazer7000EventShutdownLogResLeaf OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "To be provided." ::= { lanBlazer7000EventShutdownLogEntry 10 } lanBlazer7000EventShutdownLogValueType OBJECT-TYPE SYNTAX EventValueType ACCESS read-only STATUS mandatory DESCRIPTION "The data type associated with the ShutdownLog event value. This object indicates how to interpret the data stored in the event ShutdownLog value." ::= { lanBlazer7000EventShutdownLogEntry 11 } lanBlazer7000EventShutdownLogValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The value associated with the event encoded in an octet string. " ::= { lanBlazer7000EventShutdownLogEntry 12 } lanBlazer7000EventShutdownLogEpochTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of time ticks since the epoch when this event was logged. The interpretation of this value is as follows: struct DateTimeOvly { UNS32 year:6; UNS32 month:4; UNS32 day:5; UNS32 hour:5; UNS32 minute:6; UNS32 second:6; }; The epoch is January 1, 1997, at 00:00:00. A value of 0 refers to this date and time. " ::= { lanBlazer7000EventShutdownLogEntry 13 } lanBlazer7000EventShutdownLogID OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique index that identifies the occurence of this event. This ID can be correlated between traps, logs and the like." ::= { lanBlazer7000EventShutdownLogEntry 14 } -- EVENT TRAP DATA lanBlazer7000EventTrapMgmt OBJECT IDENTIFIER ::= { lanBlazer7000Events 6 } lanBlazer7000EventTrapEventIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index that uniquely identifies the event that caused this trap." ::= { lanBlazer7000EventTrapMgmt 1 } lanBlazer7000EventTrapTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when this event was triggered." ::= { lanBlazer7000EventTrapMgmt 2 } lanBlazer7000EventTrapDescr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The event log description." ::= { lanBlazer7000EventTrapMgmt 3 } lanBlazer7000EventTrapType OBJECT-TYPE SYNTAX EventCategory ACCESS read-only STATUS mandatory DESCRIPTION "The type of event that caused this trap." ::= { lanBlazer7000EventTrapMgmt 4 } lanBlazer7000EventTrapSeverity OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "The severity associated with this event. It is recommended that the severity be interpreted in the following manner: 0-19: Normal 20-39: Informational 40-59: Warning 60-79: Alarm 80-99: Severe Error 100: Failure." ::= { lanBlazer7000EventTrapMgmt 5 } lanBlazer7000EventTrapDTM OBJECT-TYPE SYNTAX DisplayString (SIZE (18)) ACCESS read-only STATUS mandatory DESCRIPTION "The date and time when this trap was sent. The format is yy-Mon- dd hh:mm:ss, time is in 24 hour time." ::= { lanBlazer7000EventTrapMgmt 6 } lanBlazer7000EventTrapResType OBJECT-TYPE SYNTAX ResourceType ACCESS read-only STATUS mandatory DESCRIPTION "The type of object (if provided) that triggered this event. If not provided, the value is equal to 'Invalid Resource'." ::= { lanBlazer7000EventTrapMgmt 7 } lanBlazer7000EventTrapResID OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "The instance of this resource (if provided - see lanBlazer7000EventTrapResType) that triggered this event." ::= { lanBlazer7000EventTrapMgmt 8 } lanBlazer7000EventTrapResLeaf OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A number corresponding to the attribute associated with this resource and this event entry. It corresponds exactly to the leaf MIB number of the MIB that manages this resource. For example, if a port's mode changed, the configuration event log entry would indicate the value of 5 which is the leaf index of the lanBlazer7000PortMode within the lanBlazer7000PortTable MIB table." ::= { lanBlazer7000EventTrapMgmt 9 } lanBlazer7000EventTrapValueType OBJECT-TYPE SYNTAX EventValueType ACCESS read-only STATUS mandatory DESCRIPTION "The data type associated with the trap event value. This object indicates how to interpret the data stored in the event trap value: - none(1) indicates no value returned. - integer32(2) - a 4 byte unsigned integer. - integer64(3) - an 8 byte unsigned integer. - displayString(4) - a null terminated (or up to 8 characters) string. - ipv4NetworkAddress(5) - a 4 byte IP version 4 network address. - ieee802MACAddress(6) - a 6 byte MAC Address. - timeticks(7) - sysUpTime type value (4 bytes)" ::= { lanBlazer7000EventTrapMgmt 10 } lanBlazer7000EventTrapValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "The value associated with the event encoded in an octet string. Refer to lanBlazer7000EventTrapValueType for how to interpret this value. The value encoded in this string is in Big Endian order." ::= { lanBlazer7000EventTrapMgmt 11 } lanBlazer7000EventTrapEpochTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of time ticks since the epoch when this event was logged. The interpretation of this value is as follows: struct DateTimeOvly { UNS32 year:6; UNS32 month:4; UNS32 day:5; UNS32 hour:5; UNS32 minute:6; UNS32 second:6; }; The epoch is January 1, 1997, at 00:00:00. A value of 0 refers to this date and time. " ::= { lanBlazer7000EventTrapMgmt 12 } lanBlazer7000EventTrapID OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "A unique index that identifies the occurence of this event. This ID can be correlated between traps, logs and the like." ::= { lanBlazer7000EventTrapMgmt 13 } -- ALARM MANAGEMENT lanBlazer7000AlarmMgt OBJECT IDENTIFIER ::= { odsLANBlazer7000Mib 11 } -- ALARM GENERAL lanBlazer7000AlarmGeneral OBJECT IDENTIFIER ::= { lanBlazer7000AlarmMgt 1 } -- Alarm Table -- -- The alarm table contains events that are considered "alarmable". This table is a handy place -- to quickly check the "health" of the system. Any non-normal indication in the system will be -- indicated in this table. lanBlazer7000AlarmGeneralActiveEntries OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The total number of alarm entries in the triggered state currently in the alarm table." ::= { lanBlazer7000AlarmGeneral 1 } lanBlazer7000AlarmGeneralTimeStamp OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when any alarm state last changed (either triggering a new alarm or re-arming an old one)." ::= { lanBlazer7000AlarmGeneral 2 } -- ALARM TABLE lanBlazer7000Alarms OBJECT IDENTIFIER ::= { lanBlazer7000AlarmMgt 2 } -- ACTIVE ALARM TABLE lanBlazer7000ActiveAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF LanBlazer7000ActiveAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of all alarms in the triggered state." ::= { lanBlazer7000Alarms 2 } lanBlazer7000ActiveAlarmEntry OBJECT-TYPE SYNTAX LanBlazer7000ActiveAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An alarm in the triggered state." INDEX { lanBlazer7000ActiveAlarmIndex } ::= { lanBlazer7000ActiveAlarmTable 1 } LanBlazer7000ActiveAlarmEntry ::= SEQUENCE { lanBlazer7000ActiveAlarmIndex INTEGER, lanBlazer7000ActiveAlarmName DisplayString, lanBlazer7000ActiveAlarmValueHigh INTEGER, lanBlazer7000ActiveAlarmValueLow INTEGER, lanBlazer7000ActiveAlarmVariable OBJECT IDENTIFIER, lanBlazer7000ActiveAlarmResType ResourceType, lanBlazer7000ActiveAlarmResID ResourceId, lanBlazer7000ActiveAlarmLeaf INTEGER, lanBlazer7000ActiveAlarmOwner DisplayString } lanBlazer7000ActiveAlarmIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The unique index that identifies this alarm." ::= { lanBlazer7000ActiveAlarmEntry 1 } lanBlazer7000ActiveAlarmName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) ACCESS read-only STATUS mandatory DESCRIPTION "The name of this alarm." ::= { lanBlazer7000ActiveAlarmEntry 2 } lanBlazer7000ActiveAlarmValueHigh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The high order 32 bits of the value that triggered this alarm." ::= { lanBlazer7000ActiveAlarmEntry 3 } lanBlazer7000ActiveAlarmValueLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The low order 32 bits of the value that triggered this alarm." ::= { lanBlazer7000ActiveAlarmEntry 4 } lanBlazer7000ActiveAlarmVariable OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The OID of the alarm variable if this is a user-created alarm (null otherwise)." ::= { lanBlazer7000ActiveAlarmEntry 5 } lanBlazer7000ActiveAlarmResType OBJECT-TYPE SYNTAX ResourceType ACCESS read-only STATUS mandatory DESCRIPTION "The resource type of this alarm if this is an internally created alarm." ::= { lanBlazer7000ActiveAlarmEntry 6 } lanBlazer7000ActiveAlarmResID OBJECT-TYPE SYNTAX ResourceId ACCESS read-only STATUS mandatory DESCRIPTION "The resource identifier associated with this alarm if this is an internally created alarm." ::= { lanBlazer7000ActiveAlarmEntry 7 } lanBlazer7000ActiveAlarmLeaf OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The leaf index of the MIB table used to manage this resource that is associated with this alarm, if this is an internally created alarm. For example, if this alarm was created to monitor a port's status, then the value of this object will be 6, corresponding to the leaf index of the lanBlazer7000PortStatus object." ::= { lanBlazer7000ActiveAlarmEntry 8 } lanBlazer7000ActiveAlarmOwner OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This is the owner of the alarm." ::= { lanBlazer7000ActiveAlarmEntry 9 } -- TRAP lanBlazer7000SnmpTraps OBJECT IDENTIFIER ::= { odsLANBlazer7000Mib 13 } lanBlazer7000SystemTrap TRAP-TYPE ENTERPRISE lanBlazer7000SnmpTraps VARIABLES { lanBlazer7000EventTrapEventIndex, lanBlazer7000EventTrapTime, lanBlazer7000EventTrapDescr, lanBlazer7000EventTrapType, lanBlazer7000EventTrapSeverity, lanBlazer7000EventTrapDTM, lanBlazer7000EventTrapResType, lanBlazer7000EventTrapResID, lanBlazer7000EventTrapResLeaf, lanBlazer7000EventTrapValueType, lanBlazer7000EventTrapValue, lanBlazer7000EventTrapEpochTime, lanBlazer7000EventTrapID } DESCRIPTION "A lanBlazer7000SystemTrap is sent by the agent when a system event is triggered. These events are usually triggered when the software encounters an unexpected situation, e.g. a hardware failure or a software bug." ::= 2 lanBlazer7000ConfigurationTrap TRAP-TYPE ENTERPRISE lanBlazer7000SnmpTraps VARIABLES { lanBlazer7000EventTrapEventIndex, lanBlazer7000EventTrapTime, lanBlazer7000EventTrapDescr, lanBlazer7000EventTrapType, lanBlazer7000EventTrapSeverity, lanBlazer7000EventTrapDTM, lanBlazer7000EventTrapResType, lanBlazer7000EventTrapResID, lanBlazer7000EventTrapResLeaf, lanBlazer7000EventTrapValueType, lanBlazer7000EventTrapValue, lanBlazer7000EventTrapEpochTime, lanBlazer7000EventTrapID } DESCRIPTION "A lanBlazer7000ConfigurationTrap is sent by the agent when the configuration event is triggered. These events are triggered when a configuration change is made." ::= 3 lanBlazer7000TemperatureTrap TRAP-TYPE ENTERPRISE lanBlazer7000SnmpTraps VARIABLES { lanBlazer7000EventTrapEventIndex, lanBlazer7000EventTrapTime, lanBlazer7000EventTrapDescr, lanBlazer7000EventTrapType, lanBlazer7000EventTrapSeverity, lanBlazer7000EventTrapDTM, lanBlazer7000EventTrapResType, lanBlazer7000EventTrapResID, lanBlazer7000EventTrapResLeaf, lanBlazer7000EventTrapValueType, lanBlazer7000EventTrapValue, lanBlazer7000EventTrapEpochTime, lanBlazer7000EventTrapID } DESCRIPTION "A lanBlazer7000TemperatureTrap is sent by the agent when the temperature event is triggered. This event is triggered when a temperature probe detects the temperature crossing a threshold." ::= 4 lanBlazer7000ResourceTrap TRAP-TYPE ENTERPRISE lanBlazer7000SnmpTraps VARIABLES { lanBlazer7000EventTrapEventIndex, lanBlazer7000EventTrapTime, lanBlazer7000EventTrapDescr, lanBlazer7000EventTrapType, lanBlazer7000EventTrapSeverity, lanBlazer7000EventTrapDTM, lanBlazer7000EventTrapResType, lanBlazer7000EventTrapResID, lanBlazer7000EventTrapResLeaf, lanBlazer7000EventTrapValueType, lanBlazer7000EventTrapValue, lanBlazer7000EventTrapEpochTime, lanBlazer7000EventTrapID } DESCRIPTION "A lanBlazer7000ResourceTrap is sent by the agent when the resource event is triggered. The resource event is triggered when a resource is added or removed from the system." ::= 5 lanBlazer7000FanTrap TRAP-TYPE ENTERPRISE lanBlazer7000SnmpTraps VARIABLES { lanBlazer7000EventTrapEventIndex, lanBlazer7000EventTrapTime, lanBlazer7000EventTrapDescr, lanBlazer7000EventTrapType, lanBlazer7000EventTrapSeverity, lanBlazer7000EventTrapDTM, lanBlazer7000EventTrapResType, lanBlazer7000EventTrapResID, lanBlazer7000EventTrapResLeaf, lanBlazer7000EventTrapValueType, lanBlazer7000EventTrapValue, lanBlazer7000EventTrapEpochTime, lanBlazer7000EventTrapID } DESCRIPTION "A lanBlazer7000FanTrap is sent by the agent when the fan status event is triggered. The fan status event is triggered when a fan has a change in its status." ::= 6 lanBlazer7000PowerTrap TRAP-TYPE ENTERPRISE lanBlazer7000SnmpTraps VARIABLES { lanBlazer7000EventTrapEventIndex, lanBlazer7000EventTrapTime, lanBlazer7000EventTrapDescr, lanBlazer7000EventTrapType, lanBlazer7000EventTrapSeverity, lanBlazer7000EventTrapDTM, lanBlazer7000EventTrapResType, lanBlazer7000EventTrapResID, lanBlazer7000EventTrapResLeaf, lanBlazer7000EventTrapValueType, lanBlazer7000EventTrapValue, lanBlazer7000EventTrapEpochTime, lanBlazer7000EventTrapID } DESCRIPTION "A lanBlazer7000PowerTrap is sent by the agent when the power event is triggered. These events are triggered when a power supply changes status." ::= 9 -- VLAN EXCHANGE lanBlazer7000VlanExchange OBJECT IDENTIFIER ::= { odsLANBlazer7000Mib 14 } -- VLAN EXCHANGE SWITCH -- General switch-wide objects lanBlazer7000VlanExchangeSwitch OBJECT IDENTIFIER ::= { lanBlazer7000VlanExchange 1 } lanBlazer7000VlanExchangeState OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this object is set to enable(1), the switch attempts to learn VLANs from a major networking equipment vendor on switch ports that have their VLAN Exchange parameter set to enable(1). trunking mode is IEEE 802.1Q Format or Multi-level Format. The factory default value for this object is disable(2)." ::= { lanBlazer7000VlanExchangeSwitch 1 } lanBlazer7000VlanExchangeDomainName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "The VLAN Exchange Domain Name of the switch. A switch may only belong to one domain." ::= { lanBlazer7000VlanExchangeSwitch 2 } lanBlazer7000VlanExchangeUpdaterId OBJECT-TYPE SYNTAX NetworkAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address of the switch from which the VLAN Exchange configuration was learned." ::= { lanBlazer7000VlanExchangeSwitch 3 } lanBlazer7000VlanExchangeUpdateTimeStamp OBJECT-TYPE SYNTAX DisplayString (SIZE(0..12)) ACCESS read-only STATUS mandatory DESCRIPTION "The time at which the VLAN Exchange configuration changed on the initiating switch." ::= { lanBlazer7000VlanExchangeSwitch 4 } lanBlazer7000VlanExchangeConfigRevNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Configuration Revision Number of VLAN Exchange Configuration on the switch that initiated the VLAN Exchange." ::= { lanBlazer7000VlanExchangeSwitch 5 } END