ODSLANBlazer7000-MIB :: lanBlazer7000SwitchPortSTAPMode

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › ODSLANBlazer7000-MIB › lanBlazer7000SwitchPortSTAPMode

lanBlazer7000SwitchPortSTAPMode

Module: ODSLANBlazer7000-MIB

OID (symbolic): ODSLANBlazer7000-MIB::lanBlazer7000SwitchPortSTAPMode

OID (numeric): 1.3.6.1.4.1.50.8.1.2.1.5.2.1.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Disabling spanning tree on a switch port prevents the switch port from participating in the spanning tree process. When disabled(2), this port will neither generate BPDUs, nor process received BPDUs. Also, the port will always start in the forwarding state. A port configured in this mode will not be able to detect network loops involving this port.

The factory default is to enable spanning tree on all ports.

What is lanBlazer7000SwitchPortSTAPMode?

Enables (factory default) or disables spanning tree participation on this specific switch port; when disabled(2), the port neither generates nor processes BPDUs and always starts in the forwarding state, meaning it cannot detect loops involving itself. Admins disable this only on ports they are certain cannot form a loop (e.g. a port feeding a single known end-station), since doing so removes STP's built-in loop protection for that port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.5.2.1.1.2
snmpwalk -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000SwitchPortSTAPMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.5.2.1.1.2.1
snmpget -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000SwitchPortSTAPMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.50.8.1.2.1.5.2.1.1.2.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> lanBlazer7000SwitchPortSTAPMode.1

Start monitoring ODS LANBlazer 7000 WAN test/analysis instrument with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ODSLANBlazer7000-MIB::lanBlazer7000SwitchPortSTAPMode OID value, configure state conditions and alerts, and monitor any ODS LANBlazer 7000 WAN test/analysis instrument from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.50odsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8odsTPSODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1odsLANBlazerODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2odsLANBlazerMibsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1odsLANBlazer7000MibODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5lanBlazer7000SwitchingODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.2lanBlazer7000SwitchPortMgtODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.2.1lanBlazer7000SwitchPortTableODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.2.1.1lanBlazer7000SwitchPortEntryODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.2.1.1.2lanBlazer7000SwitchPortSTAPModeODSLANBlazer7000-MIB