ODSLANBlazer7000-MIB :: lanBlazer7000SwitchPortConvertToStatic

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › ODSLANBlazer7000-MIB › lanBlazer7000SwitchPortConvertToStatic

lanBlazer7000SwitchPortConvertToStatic

Module: ODSLANBlazer7000-MIB

OID (symbolic): ODSLANBlazer7000-MIB::lanBlazer7000SwitchPortConvertToStatic

OID (numeric): 1.3.6.1.4.1.50.8.1.2.1.5.2.1.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: When this object is set to convertToStatic(2), all addresses learned on this port will be added to the non-volatile version of the static address table.

Typically, this object will be used to perform a crude form of address database update where the address activity associated with this port is collected as static (i.e. permanent) addresses while the value of this object is set to convertToStatic(2). Following this usually short period of time (perhaps a week of activity), the value of this object is restored back to its default value of learnAsDynamic(1) and learning for this port is disabled.

It is important that the user verify the address database to verify that only the desired addresses were made permanent.

What is lanBlazer7000SwitchPortConvertToStatic?

A transient mode that, when set to convertToStatic(2), causes every address dynamically learned on this port to be written into the non-volatile static address table; the MIB recommends using it briefly (e.g. for about a week) to snapshot a port's known hosts before restoring it to learnAsDynamic(1) and disabling further learning. An admin uses this as a crude but effective way to "harden" a port's address set, then must manually review the resulting static entries to confirm only legitimate addresses were captured.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.5.2.1.1.3
snmpwalk -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000SwitchPortConvertToStatic

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.5.2.1.1.3.1
snmpget -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000SwitchPortConvertToStatic.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.50.8.1.2.1.5.2.1.1.3.1 i <value>

Start monitoring ODS LANBlazer 7000 WAN test/analysis instrument with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ODSLANBlazer7000-MIB::lanBlazer7000SwitchPortConvertToStatic OID value, configure state conditions and alerts, and monitor any ODS LANBlazer 7000 WAN test/analysis instrument from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.50odsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8odsTPSODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1odsLANBlazerODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2odsLANBlazerMibsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1odsLANBlazer7000MibODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5lanBlazer7000SwitchingODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.2lanBlazer7000SwitchPortMgtODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.2.1lanBlazer7000SwitchPortTableODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.2.1.1lanBlazer7000SwitchPortEntryODSLANBlazer7000-MIB