ODSLANBlazer7000-MIB :: lanBlazer7000SwitchPortAutoVlanCreation

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › ODSLANBlazer7000-MIB › lanBlazer7000SwitchPortAutoVlanCreation

lanBlazer7000SwitchPortAutoVlanCreation

Module: ODSLANBlazer7000-MIB

OID (symbolic): ODSLANBlazer7000-MIB::lanBlazer7000SwitchPortAutoVlanCreation

OID (numeric): 1.3.6.1.4.1.50.8.1.2.1.5.2.1.1.14

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Enabling auto VLAN creation for this switch port causes the port to dynamically create a VLAN whenever an IEEE 802.1Q or Multi-level tagged frame is received on the port with a tag value which does not correspond to a known VLAN. All switch ports with a trunking mode of IEEE 802.1Q or Multi-level are bound to this created VLAN. The default is disable.

What is lanBlazer7000SwitchPortAutoVlanCreation?

When enabled, causes this port to automatically create a new VLAN whenever it receives an 802.1Q or Multi-level tagged frame carrying a VLAN tag that doesn't match any VLAN the switch already knows, with every other trunk port on the switch then bound to that newly created VLAN (default is disabled). Admins enable this on trunk links in environments where VLANs are provisioned dynamically from an upstream device rather than pre-configured on every switch.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.5.2.1.1.14
snmpwalk -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000SwitchPortAutoVlanCreation

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.5.2.1.1.14.1
snmpget -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000SwitchPortAutoVlanCreation.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.50.8.1.2.1.5.2.1.1.14.1 i <value>

Start monitoring ODS LANBlazer 7000 WAN test/analysis instrument with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ODSLANBlazer7000-MIB::lanBlazer7000SwitchPortAutoVlanCreation OID value, configure state conditions and alerts, and monitor any ODS LANBlazer 7000 WAN test/analysis instrument from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.50odsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8odsTPSODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1odsLANBlazerODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2odsLANBlazerMibsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1odsLANBlazer7000MibODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5lanBlazer7000SwitchingODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.2lanBlazer7000SwitchPortMgtODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.2.1lanBlazer7000SwitchPortTableODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.2.1.1lanBlazer7000SwitchPortEntryODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.2.1.1.14lanBlazer7000SwitchPortAutoVlanCreationODSLANBlazer7000-MIB