All MIBs › ODSLANBlazer7000-MIB › lanBlazer7000PowerSupplyOutputCapacity
lanBlazer7000PowerSupplyOutputCapacity
Module: ODSLANBlazer7000-MIB
OID (symbolic): ODSLANBlazer7000-MIB::lanBlazer7000PowerSupplyOutputCapacity
OID (numeric): 1.3.6.1.4.1.50.8.1.2.1.3.3.1.1.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The total capacity of power supplied by this supply in Watts.
What is lanBlazer7000PowerSupplyOutputCapacity?
Reports the rated output capacity of this power supply in Watts, a fixed hardware characteristic used by the system's power-budgeting logic. An admin compares this value against lanBlazer7000PowerUsed across all installed supplies to judge whether there's enough headroom to add another module.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.3.3.1.1.1.6 snmpwalk -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000PowerSupplyOutputCapacity
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.3.3.1.1.1.6.1 snmpget -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000PowerSupplyOutputCapacity.1
Start monitoring ODS LANBlazer 7000 WAN test/analysis instrument with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ODSLANBlazer7000-MIB::lanBlazer7000PowerSupplyOutputCapacity OID value, configure state conditions and alerts, and monitor any ODS LANBlazer 7000 WAN test/analysis instrument from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.50 | ods | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8 | odsTPS | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1 | odsLANBlazer | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2 | odsLANBlazerMibs | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2.1 | odsLANBlazer7000Mib | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2.1.3 | lanBlazer7000Chassis | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2.1.3.3 | lanBlazer7000PowerSystems | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2.1.3.3.1 | lanBlazer7000PowerSupplies | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2.1.3.3.1.1 | lanBlazer7000PowerSupplyTable | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2.1.3.3.1.1.1 | lanBlazer7000PowerSupplyEntry | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2.1.3.3.1.1.1.6 | lanBlazer7000PowerSupplyOutputCapacity | ODSLANBlazer7000-MIB |