lanBlazer7000PowerControlMode

Module: ODSLANBlazer7000-MIB

OID (symbolic): ODSLANBlazer7000-MIB::lanBlazer7000PowerControlMode

OID (numeric): 1.3.6.1.4.1.50.8.1.2.1.3.3.3.1.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Normally, a module power mode is enable(1).

In the event of a power supply failure resulting in a power shortage, or in the event of this module being inserted without enough available power, the mode will be poweredDown(3). Setting this object to the value of poweredDown(3) will result in an error.

When enough power is available, the module will power back up when in this mode. A module may be powered down through administrative action by setting the value of this object to disable(2). In this mode, the module will remain powered down until the mode is set back to enable.

What is lanBlazer7000PowerControlMode?

Reflects and controls this module's power state: enable(1) is normal operation, poweredDown(3) is a read-only state the agent sets automatically when a power shortage or insufficient available power forces the module off (attempting to set this value directly is rejected), and disable(2) lets an admin deliberately power the module down until re-enabled. An admin would set this to disable(2) to take a module offline for maintenance without physically removing it, then back to enable(1) to restore it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.3.3.3.1.1.3
snmpwalk -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000PowerControlMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.3.3.3.1.1.3.1
snmpget -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000PowerControlMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.50.8.1.2.1.3.3.3.1.1.3.1 i <value>

Start monitoring ODS LANBlazer 7000 WAN test/analysis instrument with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ODSLANBlazer7000-MIB::lanBlazer7000PowerControlMode OID value, configure state conditions and alerts, and monitor any ODS LANBlazer 7000 WAN test/analysis instrument from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.50odsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8odsTPSODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1odsLANBlazerODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2odsLANBlazerMibsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1odsLANBlazer7000MibODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3lanBlazer7000ChassisODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.3lanBlazer7000PowerSystemsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.3.3lanBlazer7000PowerMgmtCtlODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.3.3.1lanBlazer7000PowerControlTableODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.3.3.1.1lanBlazer7000PowerControlEntryODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.3.3.1.1.3lanBlazer7000PowerControlModeODSLANBlazer7000-MIB