ODSLANBlazer7000-MIB :: lanBlazer7000PortRateLimitRate

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › ODSLANBlazer7000-MIB › lanBlazer7000PortRateLimitRate

lanBlazer7000PortRateLimitRate

Module: ODSLANBlazer7000-MIB

OID (symbolic): ODSLANBlazer7000-MIB::lanBlazer7000PortRateLimitRate

OID (numeric): 1.3.6.1.4.1.50.8.1.2.1.3.6.6.1.1.62

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The percentage of the port's transmitted data allowed to be floods (or floods and known multicasts). For example, the factory default setting of twenty-percent(4) indicates that 20% of the data rate can be floods. For 10 Mb/s ports, this is equivalent to a maximum rate of approximately 3000 flooded pps; for 100 Mb/s ports, a maximum rate of approximately 30,000 flooded pps.

What is lanBlazer7000PortRateLimitRate?

Sets the percentage of this port's transmit bandwidth that may be consumed by flooded traffic, from one-percent(1) up to eighty-percent(7), with twenty-percent(4) as the factory default — roughly 3,000 flooded packets/sec on a 10 Mb/s port or 30,000 pps on 100 Mb/s. An admin lowers this on a port serving a sensitive application to leave more guaranteed bandwidth for legitimate unicast traffic even during a broadcast storm elsewhere on the LAN.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.3.6.6.1.1.62
snmpwalk -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000PortRateLimitRate

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.3.6.6.1.1.62.1
snmpget -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000PortRateLimitRate.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.50.8.1.2.1.3.6.6.1.1.62.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> lanBlazer7000PortRateLimitRate.1

Start monitoring ODS LANBlazer 7000 WAN test/analysis instrument with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ODSLANBlazer7000-MIB::lanBlazer7000PortRateLimitRate OID value, configure state conditions and alerts, and monitor any ODS LANBlazer 7000 WAN test/analysis instrument from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.50odsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8odsTPSODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1odsLANBlazerODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2odsLANBlazerMibsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1odsLANBlazer7000MibODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3lanBlazer7000ChassisODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.6lanBlazer7000PortsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.6.6lanBlazer7000PortRateLimitMgtODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.6.6.1lanBlazer7000PortRateLimitTableODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.6.6.1.1lanBlazer7000PortRateLimitEntryODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.6.6.1.1.62lanBlazer7000PortRateLimitRateODSLANBlazer7000-MIB