ODSLANBlazer7000-MIB :: lanBlazer7000PortFlowControlMode

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › ODSLANBlazer7000-MIB › lanBlazer7000PortFlowControlMode

lanBlazer7000PortFlowControlMode

Module: ODSLANBlazer7000-MIB

OID (symbolic): ODSLANBlazer7000-MIB::lanBlazer7000PortFlowControlMode

OID (numeric): 1.3.6.1.4.1.50.8.1.2.1.3.6.2.1.1.21

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Flow control is used to prevent or reduce the dropping of frames due to the lack of buffer space. Overall, networks are more efficient when a sending station is asked to pause in its sending process, rather than having the transmitted frames dropped.

Flow control is not as efficient when used in conjunction with a shared ports, i.e. when used with a repeater. Therefore, flow control is not recommended for a port connected to shared topologies.

Flow control is most effective when the port is directly connected to an end-station, especially when connected to a server. Flow control is recommended for ports connected directly to end-stations.

When the port is in half-duplex mode, back pressure is used to control the incoming flow. Back pressure essentially forces collisions for short periods of time.

When the port is in full-duplex mode, IEEE 802.3 standard pause frames are used to control the incoming flow.

Note that setting an ether-gigabit(4) port to enable-with-aggressive-backoff(3) results in an error.

What is lanBlazer7000PortFlowControlMode?

Controls 802.3 flow control on this port: enable(1) lets the switch send pause frames (full-duplex) or use back-pressure (half-duplex) to ask an overwhelmed sender to slow down rather than dropping frames, disable(2) turns this off, and enable-with-aggressive-backoff(3) applies a more assertive back-pressure variant (not settable on ether-gigabit(4) ports, which rejects that mode). An admin enables flow control on a port connected directly to a server to avoid frame loss under burst traffic, but leaves it disabled on a port feeding a shared repeater segment where it is less effective.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.3.6.2.1.1.21
snmpwalk -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000PortFlowControlMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.3.6.2.1.1.21.1
snmpget -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000PortFlowControlMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.50.8.1.2.1.3.6.2.1.1.21.1 i <value>

Start monitoring ODS LANBlazer 7000 WAN test/analysis instrument with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ODSLANBlazer7000-MIB::lanBlazer7000PortFlowControlMode OID value, configure state conditions and alerts, and monitor any ODS LANBlazer 7000 WAN test/analysis instrument from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.50odsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8odsTPSODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1odsLANBlazerODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2odsLANBlazerMibsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1odsLANBlazer7000MibODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3lanBlazer7000ChassisODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.6lanBlazer7000PortsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.6.2lanBlazer7000PortFlowControlMgtODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.6.2.1lanBlazer7000PortFlowControlTableODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.6.2.1.1lanBlazer7000PortFlowControlEntryODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.3.6.2.1.1.21lanBlazer7000PortFlowControlModeODSLANBlazer7000-MIB