lanBlazer7000L2AddressControlPersistence
Module: ODSLANBlazer7000-MIB
OID (symbolic): ODSLANBlazer7000-MIB::lanBlazer7000L2AddressControlPersistence
OID (numeric): 1.3.6.1.4.1.50.8.1.2.1.5.1.4.3.1.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The persistence of the entry to be created:
permanent(1) - Address is not aged out. Additionally, if the address is seen as a source on a different port for this VLAN, the frame is filtered and the filter event is counted. Static address entries are stored in non-volatile memory and are restored to the address table following each system reset.
deleteOnReset(2) - Indicates that the entry is not to be aged, however the entry is not stored in non-volatile memory. Therefore, when the device is reset, the entry will not be restored.
deleteOnTimeout(3) - Indicates that the entry is to be aged by the normal aging process.
What is lanBlazer7000L2AddressControlPersistence?
Chooses the aging behavior of the static entry being created: permanent(1) never ages and survives reboot (and triggers a filter/alarm if the MAC later appears on a different port in the same VLAN), deleteOnReset(2) never ages but is lost on reboot, and deleteOnTimeout(3) ages out normally like a dynamically learned entry. An admin typically picks permanent(1) when pinning a critical server's MAC to a port for both forwarding efficiency and move-detection security.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.5.1.4.3.1.1.6 snmpwalk -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000L2AddressControlPersistence
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.5.1.4.3.1.1.6.1 snmpget -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000L2AddressControlPersistence.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.50.8.1.2.1.5.1.4.3.1.1.6.1 i <value>
Start monitoring ODS LANBlazer 7000 WAN test/analysis instrument with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ODSLANBlazer7000-MIB::lanBlazer7000L2AddressControlPersistence OID value, configure state conditions and alerts, and monitor any ODS LANBlazer 7000 WAN test/analysis instrument from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.50 | ods | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8 | odsTPS | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1 | odsLANBlazer | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2 | odsLANBlazerMibs | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2.1 | odsLANBlazer7000Mib | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2.1.5 | lanBlazer7000Switching | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2.1.5.1 | lanBlazer7000SwitchingLayerII | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2.1.5.1.4 | lanBlazer7000L2AddrMgmt | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2.1.5.1.4.3 | lanBlazer7000L2AddrControlMgt | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2.1.5.1.4.3.1 | lanBlazer7000L2AddressControlTable | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2.1.5.1.4.3.1.1 | lanBlazer7000L2AddressControlEntry | ODSLANBlazer7000-MIB |
| 1.3.6.1.4.1.50.8.1.2.1.5.1.4.3.1.1.6 | lanBlazer7000L2AddressControlPersistence | ODSLANBlazer7000-MIB |