Description: The switch port index that serves as the base port for this hunt group. Each hunt group requires a base port. In lieu of a specific configuration, the hunt group will inherit the first switch port bound to the hunt group as its base port.

The base port serves as the management focus for the hunt group. That is, a hunt group is managed as one switch port whose instance is provided by the base switch port. All configuration (e.g. spanning tree information) and statistics related to switch ports are meaningful only through the instance of the base port.

What is lanBlazer7000HuntGroupBasePort?

Identifies the switch port that serves as this hunt group's base (management focus) port; absent explicit configuration, the hunt group inherits whichever switch port was first bound to it. Because all spanning-tree configuration and port statistics for the aggregated group are only meaningful through this one representative instance, admins query and configure the hunt group primarily via its base port rather than each member port individually.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.5.4.1.1.3
snmpwalk -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000HuntGroupBasePort

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.5.4.1.1.3.1
snmpget -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000HuntGroupBasePort.1

Start monitoring ODS LANBlazer 7000 WAN test/analysis instrument with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ODSLANBlazer7000-MIB::lanBlazer7000HuntGroupBasePort OID value, configure state conditions and alerts, and monitor any ODS LANBlazer 7000 WAN test/analysis instrument from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.50odsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8odsTPSODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1odsLANBlazerODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2odsLANBlazerMibsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1odsLANBlazer7000MibODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5lanBlazer7000SwitchingODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.4lanBlazer7000HuntGroupMgtODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.4.1lanBlazer7000HuntGroupTableODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.4.1.1lanBlazer7000HuntGroupEntryODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.4.1.1.3lanBlazer7000HuntGroupBasePortODSLANBlazer7000-MIB