ODSLANBlazer7000-MIB :: lanBlazer7000BridgeStpBridgeMaxAge

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › ODSLANBlazer7000-MIB › lanBlazer7000BridgeStpBridgeMaxAge

lanBlazer7000BridgeStpBridgeMaxAge

Module: ODSLANBlazer7000-MIB

OID (symbolic): ODSLANBlazer7000-MIB::lanBlazer7000BridgeStpBridgeMaxAge

OID (numeric): 1.3.6.1.4.1.50.8.1.2.1.5.1.2.1.1.15

Node type: OBJECT-TYPE

Type: Timeout

Access: read-write

Description: The value of MaxAge when this bridge is the root. See dot1dStpBridgeMaxAge.

What is lanBlazer7000BridgeStpBridgeMaxAge?

Sets, in the range 600-4000 (hundredths of a second, i.e. 6-40s), the Max Age value this bridge will advertise to the rest of the network if it becomes the spanning-tree root, equivalent to the standard dot1dStpBridgeMaxAge object. Admins raise this on a geographically large or high-latency network to give BPDUs more time to propagate before information is considered stale.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.5.1.2.1.1.15
snmpwalk -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000BridgeStpBridgeMaxAge

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.50.8.1.2.1.5.1.2.1.1.15.1
snmpget -v2c -c public <target> ODSLANBlazer7000-MIB::lanBlazer7000BridgeStpBridgeMaxAge.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.50.8.1.2.1.5.1.2.1.1.15.1 s <value>

Start monitoring ODS LANBlazer 7000 WAN test/analysis instrument with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ODSLANBlazer7000-MIB::lanBlazer7000BridgeStpBridgeMaxAge OID value, configure state conditions and alerts, and monitor any ODS LANBlazer 7000 WAN test/analysis instrument from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.50odsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8odsTPSODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1odsLANBlazerODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2odsLANBlazerMibsODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1odsLANBlazer7000MibODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5lanBlazer7000SwitchingODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.1lanBlazer7000SwitchingLayerIIODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.1.2lanBlazer7000BridgeMgmtODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.1.2.1lanBlazer7000BridgeTableODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.1.2.1.1lanBlazer7000BridgeEntryODSLANBlazer7000-MIB
1.3.6.1.4.1.50.8.1.2.1.5.1.2.1.1.15lanBlazer7000BridgeStpBridgeMaxAgeODSLANBlazer7000-MIB