All MIBs › OCMP311TRAP-MIB
Category: WAN Test Equipment
Description: Defines SNMP traps for fault and status change events on OCMP311 series network equipment.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OCMP311TRAP-MIB?
OCMP311TRAP-MIB is a vendor-specific notification module defining SNMP traps for fault and status-change events on OCMP311-series network equipment, following a generic alarm-reporting pattern common in telecom-style trap MIBs. Each trap carries a standardized set of alarm fields: source platform/object identity, perceived severity, alarm text, probable cause, corrective action, and a timestamp, rather than exposing a tree of polled operational counters. Its monitoring purpose is entirely fault-management: it lets a network management station receive, classify by severity, and log hardware or software alarm conditions on the equipment as they happen, functioning as the device's event/fault channel rather than a performance-metrics source. This trap structure closely mirrors ITU-T/telecom alarm models (perceived severity, probable cause), suggesting an implicit conceptual dependency on those standard alarm-reporting conventions even if not formally imported. It is deployed wherever OCMP311-series equipment is installed, typically in a carrier or service-provider network with a centralized fault-management system collecting these traps. Engineers can download the OCMP311TRAP-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OCMP311TRAP-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- HP OpenCall Media Platform (OCMP) 3.11 media server
Monitoring Examples
An NMS receiving an OCMP311 trap would read sourcePlatformEntity and sourceObjectID to identify exactly which component raised the alarm, then use perceivedSeverity to prioritize response, escalating urgently on a 'critical' severity trap. The alarmText and probableCause fields give a human-readable description and likely root cause of the fault, while correctiveAction suggests a remediation step and timeStamp records exactly when the fault condition was detected, together forming a complete fault ticket for the operator.
What Can Be Monitored
- alarm severity
- alarm source object/entity
- probable cause of fault
- suggested corrective action
- alarm timestamp
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| enterprises |
From RFC1213-MIB
| DisplayString |
OIDs
RFC description
OCMP311 trap notification MIB defining SNMP trap definitions for event notification on Oracle/Ocmp systems and devices.
Start monitoring HP OpenCall Media Platform (OCMP) 3.11 media server (fault/alarm traps) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.