OACOMMON-MIB :: netSpireDeviceFaultActive

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › OACOMMON-MIB › netSpireDeviceFaultActive

netSpireDeviceFaultActive

Module: OACOMMON-MIB

OID (symbolic): OACOMMON-MIB::netSpireDeviceFaultActive

OID (numeric): 1.3.6.1.4.1.1732.2.1.17

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Whether the fault is active or not.

What is netSpireDeviceFaultActive?

Reports whether the device currently has at least one active fault: Inactive(0) means no fault is active, Active(1) means one or more faults are currently raised.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1732.2.1.17
snmpwalk -v2c -c public <target> OACOMMON-MIB::netSpireDeviceFaultActive

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1732.2.1.17.1
snmpget -v2c -c public <target> OACOMMON-MIB::netSpireDeviceFaultActive.1

Start monitoring Open Access NetSpire network device (identity, alarm, and system health telemetry) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OACOMMON-MIB::netSpireDeviceFaultActive OID value, configure state conditions and alerts, and monitor any Open Access NetSpire network device (identity, alarm, and system health telemetry) from a single console.

How to Use in IPNetwork Monitor

Select an Open Access NetSpire network device (identity, alarm, and system health telemetry) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type netSpireDeviceFaultActive into the Find box to locate it in the OID tree, then select it and click OK. It reports the whether the fault is active or not. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'Inactive', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1732oaOA-SMI
1.3.6.1.4.1.1732.2oacommonOA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1732.2.1netspireOACOMMON-MIB
1.3.6.1.4.1.1732.2.1.17netSpireDeviceFaultActiveOACOMMON-MIB