All MIBs › Nortel-MsCarrier-MscPassport-MgmtInterfacesMIB › mscNmisTelnetSessionDataStreams
mscNmisTelnetSessionDataStreams
Module: Nortel-MsCarrier-MscPassport-MgmtInterfacesMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-MgmtInterfacesMIB::mscNmisTelnetSessionDataStreams
OID (numeric): 1.3.6.1.4.1.562.36.2.1.17.3.2.10.1.2
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-write
Description: This attribute indicates which data streams (alarm, debug, log, scn) will be transmitted back to the operator through this session. Only a userid with a command impact of system administration may register for logs.
When a client connection is up through this interface, all of the values are turned off. This means that this data is discarded when the session has a Telnet client connection set up.
When the client connection terminates, the data which was being received prior to the client being set up is requested again.
Description of bits: notused0(0) alarm(1) log(2) debug(3) scn(4)
What is mscNmisTelnetSessionDataStreams?
A bitmap controlling which data streams (alarm, log, debug, scn) this Telnet session receives; all bits are forced off while this session also has an outgoing Telnet client connection up, and the previously-selected streams are re-requested once that client connection ends.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.17.3.2.10.1.2 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-MgmtInterfacesMIB::mscNmisTelnetSessionDataStreams
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.17.3.2.10.1.2.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-MgmtInterfacesMIB::mscNmisTelnetSessionDataStreams.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.17.3.2.10.1.2.1 s <value>
Start monitoring Nortel/Bay Networks MscPassport switch (management interface ports) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-MgmtInterfacesMIB::mscNmisTelnetSessionDataStreams OID value, configure state conditions and alerts, and monitor any Nortel/Bay Networks MscPassport switch (management interface ports) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.17 | mscNmis | Nortel-MsCarrier-MscPassport-MgmtInterfacesMIB |
| 1.3.6.1.4.1.562.36.2.1.17.3 | mscNmisTelnet | Nortel-MsCarrier-MscPassport-MgmtInterfacesMIB |
| 1.3.6.1.4.1.562.36.2.1.17.3.2 | mscNmisTelnetSession | Nortel-MsCarrier-MscPassport-MgmtInterfacesMIB |
| 1.3.6.1.4.1.562.36.2.1.17.3.2.10 | mscNmisTelnetSessionOperTable | Nortel-MsCarrier-MscPassport-MgmtInterfacesMIB |
| 1.3.6.1.4.1.562.36.2.1.17.3.2.10.1 | mscNmisTelnetSessionOperEntry | Nortel-MsCarrier-MscPassport-MgmtInterfacesMIB |
| 1.3.6.1.4.1.562.36.2.1.17.3.2.10.1.2 | mscNmisTelnetSessionDataStreams | Nortel-MsCarrier-MscPassport-MgmtInterfacesMIB |