All MIBs › Nortel-MsCarrier-MscPassport-IpiVcMIB › mscIpivcDnaCugPrivileged
mscIpivcDnaCugPrivileged
Module: Nortel-MsCarrier-MscPassport-IpiVcMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-IpiVcMIB::mscIpivcDnaCugPrivileged
OID (numeric): 1.3.6.1.4.1.562.36.2.1.51.2.2.10.1.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This attribute, if set to a value of yes indicates that this CUG is a privileged CUG. In DPN, at least one side of a call setup within a CUG must have the CUG as a privileged CUG. If set to a value of no, then the CUG is not privileged. If both the local DTE and the remote DTE subscribe to the CUG, but it is not privileged, then the call will be cleared. This attribute is typically used for a host DTE which must accept calls from many other DTEs in which case the other DTEs cannot call one another, but can call the host. In this example, the host would have the privileged CUG, and the other DTEs would belong to the same CUG, but it would not be privileged.
What is mscIpivcDnaCugPrivileged?
Marks this CUG as privileged, meaning at least one side of a call within it doesn't need reciprocal membership to receive calls - typically used so a host Dna can accept calls from many peer Dnas that cannot call each other directly.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.51.2.2.10.1.7 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-IpiVcMIB::mscIpivcDnaCugPrivileged
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.51.2.2.10.1.7.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-IpiVcMIB::mscIpivcDnaCugPrivileged.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.51.2.2.10.1.7.1 i <value>
Start monitoring Nortel MsCarrier MscPassport switch (IP-over-VC encapsulation) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-IpiVcMIB::mscIpivcDnaCugPrivileged OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier MscPassport switch (IP-over-VC encapsulation) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.51 | mscIpivc | Nortel-MsCarrier-MscPassport-IpiVcMIB |
| 1.3.6.1.4.1.562.36.2.1.51.2 | mscIpivcDna | Nortel-MsCarrier-MscPassport-IpiVcMIB |
| 1.3.6.1.4.1.562.36.2.1.51.2.2 | mscIpivcDnaCug | Nortel-MsCarrier-MscPassport-IpiVcMIB |
| 1.3.6.1.4.1.562.36.2.1.51.2.2.10 | mscIpivcDnaCugCugOptionsTable | Nortel-MsCarrier-MscPassport-IpiVcMIB |
| 1.3.6.1.4.1.562.36.2.1.51.2.2.10.1 | mscIpivcDnaCugCugOptionsEntry | Nortel-MsCarrier-MscPassport-IpiVcMIB |
| 1.3.6.1.4.1.562.36.2.1.51.2.2.10.1.7 | mscIpivcDnaCugPrivileged | Nortel-MsCarrier-MscPassport-IpiVcMIB |