Nortel-MsCarrier-MscPassport-AtmUniMIB :: mscAtmIfUniAccountCollection

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-AtmUniMIB › mscAtmIfUniAccountCollection

mscAtmIfUniAccountCollection

Module: Nortel-MsCarrier-MscPassport-AtmUniMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-AtmUniMIB::mscAtmIfUniAccountCollection

OID (numeric): 1.3.6.1.4.1.562.36.2.1.114.6.12.1.1

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: This attribute is used to turn accounting on or off for SVC and SPVC connections. It also specifies the reason(s) for which accounting data is collected: billing, test, study, audit or force.

If the set of reasons is not empty then accounting records will be generated by this interface in the following situations: - on a TODA changeover if TODA is enabled; - every 12 hours (per connection) if TODA is disabled; - on every call clear (a call record with final cell counts).

If none of the reasons is present, then accounting will be suppressed.

The reason for collection is recorded in the accounting record, in the attribute callingCollectReason or calledCollectReason as appropriate.

Description of bits: bill(0) test(1) study(2) audit(3) force(4)

What is mscAtmIfUniAccountCollection?

A one-byte bitmask that turns SVC/SPVC accounting on this UNI on or off and records why usage data is collected (bill/test/study/audit/force bits); an admin sets the bill(0) bit to enable standard usage billing records, or clears every bit to suppress accounting for this interface entirely.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.6.12.1.1
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmUniMIB::mscAtmIfUniAccountCollection

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.6.12.1.1.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmUniMIB::mscAtmIfUniAccountCollection.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.114.6.12.1.1.1 s <value>

Start monitoring Nortel MSCarrier Passport (Magellan Passport) ATM switch (UNI signaling) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-AtmUniMIB::mscAtmIfUniAccountCollection OID value, configure state conditions and alerts, and monitor any Nortel MSCarrier Passport (Magellan Passport) ATM switch (UNI signaling) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1.114mscAtmIfNortel-MsCarrier-MscPassport-AtmCoreMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.114.6mscAtmIfUniNortel-MsCarrier-MscPassport-AtmUniMIB
1.3.6.1.4.1.562.36.2.1.114.6.12mscAtmIfUniAcctOptTableNortel-MsCarrier-MscPassport-AtmUniMIB
1.3.6.1.4.1.562.36.2.1.114.6.12.1mscAtmIfUniAcctOptEntryNortel-MsCarrier-MscPassport-AtmUniMIB
1.3.6.1.4.1.562.36.2.1.114.6.12.1.1mscAtmIfUniAccountCollectionNortel-MsCarrier-MscPassport-AtmUniMIB