Nortel-Magellan-Passport-PorsVcMIB :: rtgPorsProfRequiredTxBandwidth

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNortel-Magellan-Passport-PorsVcMIBrtgPorsProfRequiredTxBandwidth

rtgPorsProfRequiredTxBandwidth

Module: Nortel-Magellan-Passport-PorsVcMIB

OID (symbolic): Nortel-Magellan-Passport-PorsVcMIB::rtgPorsProfRequiredTxBandwidth

OID (numeric): 1.3.6.1.4.1.562.2.4.1.40.6.7.11.1.5

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: This attribute specifies the bandwidth (in bits per second) reserved by a path on each of the trunks of its route.This attribute represents the bandwidth for traffic outgoing to the remote end point. This value should be chosen to achieve the amount of statistical bandwidth sharing that is desired by the network administration. This reservation is not enforced but is used to determine how many paths can be supported on a trunk. Both ends should be provisioned with the correct values allowing for the fact that transmit at this end represents receive at the remote end. Note that when the values do not correspond, the originating end of the connection determines the value. A value of 0 (the default) means that the bandwidth will be the Peak Cell Rate for CLP0+1 as chosen by the user. A non zero value overrides this reservation.

What is rtgPorsProfRequiredTxBandwidth?

Sets the outbound bandwidth, in bits per second (0-155,520,000), reserved on each trunk for connections using this profile; 0 (the default) falls back to the connection's Peak Cell Rate for CLP0+1. Set both ends' Tx/Rx values consistently, since a mismatch is resolved using the originating end's value.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.40.6.7.11.1.5
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-PorsVcMIB::rtgPorsProfRequiredTxBandwidth

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.40.6.7.11.1.5.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-PorsVcMIB::rtgPorsProfRequiredTxBandwidth.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.40.6.7.11.1.5.1 i <value>

Start monitoring Nortel Magellan Passport WAN switch (PORS virtual-circuit route selection) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-PorsVcMIB::rtgPorsProfRequiredTxBandwidth OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport WAN switch (PORS virtual-circuit route selection) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1.40rtgNortel-Magellan-Passport-BaseRoutingMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.40.6rtgPorsNortel-Magellan-Passport-PorsVcMIB
1.3.6.1.4.1.562.2.4.1.40.6.7rtgPorsProfNortel-Magellan-Passport-PorsVcMIB
1.3.6.1.4.1.562.2.4.1.40.6.7.11rtgPorsProfProvTableNortel-Magellan-Passport-PorsVcMIB
1.3.6.1.4.1.562.2.4.1.40.6.7.11.1rtgPorsProfProvEntryNortel-Magellan-Passport-PorsVcMIB
1.3.6.1.4.1.562.2.4.1.40.6.7.11.1.5rtgPorsProfRequiredTxBandwidthNortel-Magellan-Passport-PorsVcMIB