Nortel-Magellan-Passport-ModDprsQosMIB :: modFrsDprsNetTpmEmissionPriority

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-Magellan-Passport-ModDprsQosMIB › modFrsDprsNetTpmEmissionPriority

modFrsDprsNetTpmEmissionPriority

Module: Nortel-Magellan-Passport-ModDprsQosMIB

OID (symbolic): Nortel-Magellan-Passport-ModDprsQosMIB::modFrsDprsNetTpmEmissionPriority

OID (numeric): 1.3.6.1.4.1.562.2.4.1.16.3.3.2.10.1.1

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: This attribute specifies the egress emission priority at the Frame Relay interface. A value of 3 specifies the highest priority, whereas a value of 0 specifies the lowest priority.

What is modFrsDprsNetTpmEmissionPriority?

This read-write Unsigned32 (0-3) specifies the egress emission priority applied at the Frame Relay interface for a given transfer priority mapping, where 3 is the highest priority and 0 the lowest, defaulting to 0. Admins raise this value for mappings that should be forwarded ahead of other traffic during congestion at the Frame Relay egress interface. For example, setting this to 3 for a voice-carrying transfer priority ensures those frames are emitted before lower-priority data traffic when the interface is congested.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.16.3.3.2.10.1.1
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-ModDprsQosMIB::modFrsDprsNetTpmEmissionPriority

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.16.3.3.2.10.1.1.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-ModDprsQosMIB::modFrsDprsNetTpmEmissionPriority.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.16.3.3.2.10.1.1.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> modFrsDprsNetTpmEmissionPriority.1

Start monitoring Nortel Magellan Passport WAN switch module (Frame Relay over DPRS QoS) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-ModDprsQosMIB::modFrsDprsNetTpmEmissionPriority OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport WAN switch module (Frame Relay over DPRS QoS) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1.16modNortel-Magellan-Passport-ShelfMIB
1.3.6.1.4.1.562.2.4.1.16.3modFrsNortel-Magellan-Passport-ModCommonMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.16.3.3modFrsDprsNetNortel-Magellan-Passport-ModDprsQosMIB
1.3.6.1.4.1.562.2.4.1.16.3.3.2modFrsDprsNetTpmNortel-Magellan-Passport-ModDprsQosMIB
1.3.6.1.4.1.562.2.4.1.16.3.3.2.10modFrsDprsNetTpmProvTableNortel-Magellan-Passport-ModDprsQosMIB
1.3.6.1.4.1.562.2.4.1.16.3.3.2.10.1modFrsDprsNetTpmProvEntryNortel-Magellan-Passport-ModDprsQosMIB
1.3.6.1.4.1.562.2.4.1.16.3.3.2.10.1.1modFrsDprsNetTpmEmissionPriorityNortel-Magellan-Passport-ModDprsQosMIB