All MIBs › Nortel-Magellan-Passport-MgmtInterfacesMIB › nmisTelnetSessionDataStreams
nmisTelnetSessionDataStreams
Module: Nortel-Magellan-Passport-MgmtInterfacesMIB
OID (symbolic): Nortel-Magellan-Passport-MgmtInterfacesMIB::nmisTelnetSessionDataStreams
OID (numeric): 1.3.6.1.4.1.562.2.4.1.17.3.2.10.1.2
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-write
Description: This attribute indicates which data streams (alarm, debug, log, scn) will be transmitted back to the operator through this session. Only a userid with a command impact of system administration may register for logs.
When a client connection is up through this interface, all of the values are turned off. This means that this data is discarded when the session has a Telnet client connection set up.
When the client connection terminates, the data which was being received prior to the client being set up is requested again.
Description of bits: notused0(0) alarm(1) log(2) debug(3) scn(4)
What is nmisTelnetSessionDataStreams?
This read-write 1-byte bitmask controls which log streams (alarm, log, debug, scn) are pushed to this Telnet session; per the source, all bits are forced off while an outbound Telnet client connection is active through this same session (that traffic is discarded until the client connection ends, at which point the previously-selected streams are automatically re-requested).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.17.3.2.10.1.2 snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-MgmtInterfacesMIB::nmisTelnetSessionDataStreams
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.17.3.2.10.1.2.1 snmpget -v2c -c public <target> Nortel-Magellan-Passport-MgmtInterfacesMIB::nmisTelnetSessionDataStreams.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.17.3.2.10.1.2.1 s <value>
Start monitoring Nortel Magellan Passport WAN switch (Network Management Interface Server) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-MgmtInterfacesMIB::nmisTelnetSessionDataStreams OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport WAN switch (Network Management Interface Server) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.2 | magellan | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.2.4 | passport | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.2.4.1 | components | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.2.4.1.17 | nmis | Nortel-Magellan-Passport-MgmtInterfacesMIB |
| 1.3.6.1.4.1.562.2.4.1.17.3 | nmisTelnet | Nortel-Magellan-Passport-MgmtInterfacesMIB |
| 1.3.6.1.4.1.562.2.4.1.17.3.2 | nmisTelnetSession | Nortel-Magellan-Passport-MgmtInterfacesMIB |
| 1.3.6.1.4.1.562.2.4.1.17.3.2.10 | nmisTelnetSessionOperTable | Nortel-Magellan-Passport-MgmtInterfacesMIB |
| 1.3.6.1.4.1.562.2.4.1.17.3.2.10.1 | nmisTelnetSessionOperEntry | Nortel-Magellan-Passport-MgmtInterfacesMIB |
| 1.3.6.1.4.1.562.2.4.1.17.3.2.10.1.2 | nmisTelnetSessionDataStreams | Nortel-Magellan-Passport-MgmtInterfacesMIB |