All MIBs › Nortel-Magellan-Passport-FrTraceRcvrMIB › traceSessionFrVcSegmentsSent
traceSessionFrVcSegmentsSent
Module: Nortel-Magellan-Passport-FrTraceRcvrMIB
OID (symbolic): Nortel-Magellan-Passport-FrTraceRcvrMIB::traceSessionFrVcSegmentsSent
OID (numeric): 1.3.6.1.4.1.562.2.4.1.106.3.3.2.11.1.4
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-only
Description: This attribute displays the number of segments sent at the time command was issued. This is the segment sent count maintained by accounting at the source Vc. Vc only counts packets that Vc thinks can be delivered successfully into the subnet. In reality, these packets may be dropped by trunking, for instance. This counter is not updated when splitting fails, when Vc is in a path recovery state, when packet forwarding fails to forward this packet and when subsequent packets have to be discarded as we want to minimize the chance of out-of-sequence and do not intentionally send out-of- sequenced packets into the subnet.
What is traceSessionFrVcSegmentsSent?
This read-only value (0-16777215) counts segments the source Vc believed it successfully forwarded into the subnet at the time the command was issued; it does not increment when splitting fails, during Vc recovery, or when packets are deliberately dropped to avoid out-of-sequence delivery. An admin should note it reflects the Vc's own best-effort send count, not confirmed delivery, since the subnet could still drop these packets afterward.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.106.3.3.2.11.1.4 snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-FrTraceRcvrMIB::traceSessionFrVcSegmentsSent
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.106.3.3.2.11.1.4.1 snmpget -v2c -c public <target> Nortel-Magellan-Passport-FrTraceRcvrMIB::traceSessionFrVcSegmentsSent.1
Start monitoring Nortel Magellan Passport switch (Frame Relay trace receiver) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-FrTraceRcvrMIB::traceSessionFrVcSegmentsSent OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport switch (Frame Relay trace receiver) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.2 | magellan | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.2.4 | passport | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.2.4.1 | components | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.2.4.1.106 | trace | Nortel-Magellan-Passport-TraceBaseMIB |
| 1.3.6.1.4.1.562.2.4.1.106.3 | traceSession | Nortel-Magellan-Passport-TraceBaseMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.2.4.1.106.3.3 | traceSessionFr | Nortel-Magellan-Passport-FrTraceRcvrMIB |
| 1.3.6.1.4.1.562.2.4.1.106.3.3.2 | traceSessionFrVc | Nortel-Magellan-Passport-FrTraceRcvrMIB |
| 1.3.6.1.4.1.562.2.4.1.106.3.3.2.11 | traceSessionFrVcIntdTable | Nortel-Magellan-Passport-FrTraceRcvrMIB |
| 1.3.6.1.4.1.562.2.4.1.106.3.3.2.11.1 | traceSessionFrVcIntdEntry | Nortel-Magellan-Passport-FrTraceRcvrMIB |
| 1.3.6.1.4.1.562.2.4.1.106.3.3.2.11.1.4 | traceSessionFrVcSegmentsSent | Nortel-Magellan-Passport-FrTraceRcvrMIB |