Nortel-Magellan-Passport-FrTraceRcvrMIB :: traceSessionFrVcSegmentsRx

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-Magellan-Passport-FrTraceRcvrMIB › traceSessionFrVcSegmentsRx

traceSessionFrVcSegmentsRx

Module: Nortel-Magellan-Passport-FrTraceRcvrMIB

OID (symbolic): Nortel-Magellan-Passport-FrTraceRcvrMIB::traceSessionFrVcSegmentsRx

OID (numeric): 1.3.6.1.4.1.562.2.4.1.106.3.3.2.11.1.3

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: This attribute displays the number of segments received at the time command was issued. This is the segment received count maintained by accounting at each end of the Vc. This counter is updated only when the packet cannot be successfully delivered out of the sink Vc and to the sink AP Conditions in which packets may be discarded by the sink Vc include: missing packets due to subnet discards, segmentation protocol violations due to subnet discard, duplicated and out-of-ranged packets and packets that arrive while Vc is in path recovery state.

What is traceSessionFrVcSegmentsRx?

This read-only value (0-16777215) counts segments received by this Vc that could not be successfully delivered out of the sink Vc to the destination application — for example due to subnet discards, segmentation protocol violations, duplicates, or packets arriving during path recovery. Despite the name, this is a discard/problem counter rather than a simple total-received count, so an admin should read a rising value as a sign of delivery trouble, not just traffic volume.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.106.3.3.2.11.1.3
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-FrTraceRcvrMIB::traceSessionFrVcSegmentsRx

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.106.3.3.2.11.1.3.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-FrTraceRcvrMIB::traceSessionFrVcSegmentsRx.1

Start monitoring Nortel Magellan Passport switch (Frame Relay trace receiver) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-FrTraceRcvrMIB::traceSessionFrVcSegmentsRx OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport switch (Frame Relay trace receiver) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1.106traceNortel-Magellan-Passport-TraceBaseMIB
1.3.6.1.4.1.562.2.4.1.106.3traceSessionNortel-Magellan-Passport-TraceBaseMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.106.3.3traceSessionFrNortel-Magellan-Passport-FrTraceRcvrMIB
1.3.6.1.4.1.562.2.4.1.106.3.3.2traceSessionFrVcNortel-Magellan-Passport-FrTraceRcvrMIB
1.3.6.1.4.1.562.2.4.1.106.3.3.2.11traceSessionFrVcIntdTableNortel-Magellan-Passport-FrTraceRcvrMIB
1.3.6.1.4.1.562.2.4.1.106.3.3.2.11.1traceSessionFrVcIntdEntryNortel-Magellan-Passport-FrTraceRcvrMIB
1.3.6.1.4.1.562.2.4.1.106.3.3.2.11.1.3traceSessionFrVcSegmentsRxNortel-Magellan-Passport-FrTraceRcvrMIB