Module: NETSTAR-MIB

OID (symbolic): NETSTAR-MIB::grStatusMsg

OID (numeric): 1.3.6.1.4.1.1080.1.1.1.13

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: This message contains the status information associated with the last Backup/Compare/Restore operation.

What is grStatusMsg?

This read-only string holds the status/result message from the last configuration Backup, Compare, or Restore operation, which an admin reads to see whether that operation succeeded or what error occurred.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1080.1.1.1.13
snmpwalk -v2c -c public <target> NETSTAR-MIB::grStatusMsg

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1080.1.1.1.13.1
snmpget -v2c -c public <target> NETSTAR-MIB::grStatusMsg.1

Start monitoring NetStar Gigarouter / ClusterSwitch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NETSTAR-MIB::grStatusMsg OID value, configure state conditions and alerts, and monitor any NetStar Gigarouter / ClusterSwitch from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1080netstarNETSTAR-MIB
1.3.6.1.4.1.1080.1netstar_productsNETSTAR-MIB
1.3.6.1.4.1.1080.1.1gigarouterNETSTAR-MIB
1.3.6.1.4.1.1080.1.1.1grChassisNETSTAR-MIB
1.3.6.1.4.1.1080.1.1.1.13grStatusMsgNETSTAR-MIB