NCDCHASS-MIB :: ncdchassPowerSupplyDescr

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › NCDCHASS-MIB › ncdchassPowerSupplyDescr

ncdchassPowerSupplyDescr

Module: NCDCHASS-MIB

OID (symbolic): NCDCHASS-MIB::ncdchassPowerSupplyDescr

OID (numeric): 1.3.6.1.4.1.43.20.1.4.1.1.2

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: A textual description of the power supply, including the vendor's name and version.

What is ncdchassPowerSupplyDescr?

A text description of this power supply, including vendor name and version, useful when ordering a replacement or filing a support ticket.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.43.20.1.4.1.1.2
snmpwalk -v2c -c public <target> NCDCHASS-MIB::ncdchassPowerSupplyDescr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.43.20.1.4.1.1.2.1
snmpget -v2c -c public <target> NCDCHASS-MIB::ncdchassPowerSupplyDescr.1

Start monitoring NCD networked computing device chassis (thin-client terminal hardware) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NCDCHASS-MIB::ncdchassPowerSupplyDescr OID value, configure state conditions and alerts, and monitor any NCD networked computing device chassis (thin-client terminal hardware) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.43a3ComA3COM-AUDL-R1-MIB
1.3.6.1.4.1.43.20ncdMibsA3Com-products-MIB
Numeric OIDNameModule
1.3.6.1.4.1.43.20.1ncdchassNCDCHASS-MIB
1.3.6.1.4.1.43.20.1.4ncdchassPowerSupplyNCDCHASS-MIB
1.3.6.1.4.1.43.20.1.4.1ncdchassPowerSupplyTableNCDCHASS-MIB
1.3.6.1.4.1.43.20.1.4.1.1ncdchassPowerSupplyEntryNCDCHASS-MIB
1.3.6.1.4.1.43.20.1.4.1.1.2ncdchassPowerSupplyDescrNCDCHASS-MIB