ncdchassModuleAdminStatus
Module: NCDCHASS-MIB
OID (symbolic): NCDCHASS-MIB::ncdchassModuleAdminStatus
OID (numeric): 1.3.6.1.4.1.43.20.1.2.2.1.8
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Provides desired state of the given physical module. Notice that not all values may be supported by the specified physical module. In this case an SNMP error will be returned when the set is attempted. A physical module may be activated by writing a value of enable(2).
A physical module may be de-activated by writing a value of disable(3). In a disabled state a physical module is present in the ncdchasssis but is benign.
Writing a value of reset(4) initiates a reset sequence.
A value of programLoad(5) initiates a software load sequences.
Writing a value of test(6) should start a self test sequence within the physical module.
What is ncdchassModuleAdminStatus?
The administratively desired state of this module -- enable, disable, reset, programLoad, or test -- an admin writes to activate, deactivate, reboot, push firmware to, or self-test the module (support for any given value is implementation-specific).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.43.20.1.2.2.1.8 snmpwalk -v2c -c public <target> NCDCHASS-MIB::ncdchassModuleAdminStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.43.20.1.2.2.1.8.1 snmpget -v2c -c public <target> NCDCHASS-MIB::ncdchassModuleAdminStatus.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.43.20.1.2.2.1.8.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> ncdchassModuleAdminStatus.1
Start monitoring NCD networked computing device chassis (thin-client terminal hardware) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NCDCHASS-MIB::ncdchassModuleAdminStatus OID value, configure state conditions and alerts, and monitor any NCD networked computing device chassis (thin-client terminal hardware) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.43 | a3Com | A3COM-AUDL-R1-MIB |
| 1.3.6.1.4.1.43.20 | ncdMibs | A3Com-products-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.43.20.1 | ncdchass | NCDCHASS-MIB |
| 1.3.6.1.4.1.43.20.1.2 | ncdchassPhysical | NCDCHASS-MIB |
| 1.3.6.1.4.1.43.20.1.2.2 | ncdchassModuleTable | NCDCHASS-MIB |
| 1.3.6.1.4.1.43.20.1.2.2.1 | ncdchassModuleEntry | NCDCHASS-MIB |
| 1.3.6.1.4.1.43.20.1.2.2.1.8 | ncdchassModuleAdminStatus | NCDCHASS-MIB |