MPLS-TE-STD-MIB :: mplsTunnelTotalUpTime

MIB Reference — IPNetwork Monitor

All MIBsMPLS-TE-STD-MIBmplsTunnelTotalUpTime

mplsTunnelTotalUpTime

Module: MPLS-TE-STD-MIB

OID (symbolic): MPLS-TE-STD-MIB::mplsTunnelTotalUpTime

OID (numeric): 1.3.6.1.2.1.10.166.3.2.2.1.27

Node type: OBJECT-TYPE

Type: TimeTicks

Access: read-only

Description:

This value represents the aggregate up time for all instances of this tunnel, if available. If this value is unavailable, it MUST return a value of 0.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.166.3.2.2.1.27
snmpwalk -v2c -c public <target> MPLS-TE-STD-MIB::mplsTunnelTotalUpTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.10.166.3.2.2.1.27.1
snmpget -v2c -c public <target> MPLS-TE-STD-MIB::mplsTunnelTotalUpTime.1

How to Use in IPNetwork Monitor

Select a device implementing MPLS-TE-STD-MIB as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and locate mplsTunnelTotalUpTime under the mplsTunnelEntry branch of MPLS-TE-STD-MIB, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports, in TimeTicks, the aggregate up time across all instances of this MPLS-TE tunnel. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a TimeTicks-type OID, Value bounds is the most useful condition here — trigger an alert if the value resets to (or stays at) 0 unexpectedly, which indicates the tunnel has gone down or was never established. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.2mgmtBKTEL-HFC862-BASE-MIB
1.3.6.1.2.1mib_2CHECKPOINT-MIB-2
1.3.6.1.2.1.10transmissionCHECKPOINT-MIB-2
1.3.6.1.2.1.10.166mplsStdMIBMPLS-TC-STD-MIB
1.3.6.1.2.1.10.166.3mplsTeStdMIBMPLS-TE-STD-MIB
1.3.6.1.2.1.10.166.3.2mplsTeObjectsMPLS-TE-STD-MIB
1.3.6.1.2.1.10.166.3.2.2mplsTunnelTableMPLS-TE-STD-MIB
1.3.6.1.2.1.10.166.3.2.2.1mplsTunnelEntryMPLS-TE-STD-MIB
1.3.6.1.2.1.10.166.3.2.2.1.27mplsTunnelTotalUpTimeMPLS-TE-STD-MIB