MICOM-GCM-MIB :: nvmGcmUnitPriLinkFailMonDurMin

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › MICOM-GCM-MIB › nvmGcmUnitPriLinkFailMonDurMin

nvmGcmUnitPriLinkFailMonDurMin

Module: MICOM-GCM-MIB

OID (symbolic): MICOM-GCM-MIB::nvmGcmUnitPriLinkFailMonDurMin

OID (numeric): 1.3.6.1.4.1.335.1.4.25.1.8.1.14

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: NAME = ; DESC = The number of minutes to monitor \ gcmLinkFailureMonThreshold \ activity. The duration timer \ starts when first link failure \ occured while the \ gcmLinkFailureMonStatus is \ enabled(1). \ (Configuration); HELP = ; CAPABILITIES = ;

What is nvmGcmUnitPriLinkFailMonDurMin?

Configures how many minutes GCM monitors primary-link failure activity, with the timer starting at the first failure once monitoring is enabled.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.335.1.4.25.1.8.1.14
snmpwalk -v2c -c public <target> MICOM-GCM-MIB::nvmGcmUnitPriLinkFailMonDurMin

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.335.1.4.25.1.8.1.14.1
snmpget -v2c -c public <target> MICOM-GCM-MIB::nvmGcmUnitPriLinkFailMonDurMin.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.335.1.4.25.1.8.1.14.1 i <value>

Start monitoring Micom Group Channel Multiplexer (GCM) WAN device with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MICOM-GCM-MIB::nvmGcmUnitPriLinkFailMonDurMin OID value, configure state conditions and alerts, and monitor any Micom Group Channel Multiplexer (GCM) WAN device from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.335micomMICOM-OSCAR-MIB
1.3.6.1.4.1.335.1productsMICOM-OSCAR-MIB
1.3.6.1.4.1.335.1.4micom_oscarMICOM-OSCAR-MIB
Numeric OIDNameModule
1.3.6.1.4.1.335.1.4.25micom_gcmMICOM-GCM-MIB
1.3.6.1.4.1.335.1.4.25.1configurationMICOM-GCM-MIB
1.3.6.1.4.1.335.1.4.25.1.8nvmGcmUnitTableMICOM-GCM-MIB
1.3.6.1.4.1.335.1.4.25.1.8.1nvmGcmUnitEntryMICOM-GCM-MIB
1.3.6.1.4.1.335.1.4.25.1.8.1.14nvmGcmUnitPriLinkFailMonDurMinMICOM-GCM-MIB