| OID symbolic | OID numeric | Type | Access | Description |
| memberBody | 1.2 | | | |
| gb | 1.2.826 | | | |
| gbNational | 1.2.826.0 | | | |
| gbNatCompany | 1.2.826.0.1 | | | |
| dataConnection | 1.2.826.0.1.1578918 | | | |
| metaSwitch | 1.2.826.0.1.1578918.6 | | | |
| metaswitchInfo | 1.2.826.0.1.1578918.6.1 | | | |
| STR metaswitchInfoVersion | 1.2.826.0.1.1578918.6.1.1 | DisplayString | read-only | MetaSwitch MIB Version |
| unassignedOID | 1.2.826.0.1.1578918.6.999999 | | | |
| dataConnectionTraps | 1.3.6.1.4.1.19444 | | | |
| metaSwitchEMS | 1.3.6.1.4.1.19444.6 | | | |
| metaswitchTraps | 1.3.6.1.4.1.19444.6.2 | | | |
| alarmTrapsPrefix | 1.3.6.1.4.1.19444.6.2.1 | | | |
| NTF alarmTrap | 1.3.6.1.4.1.19444.6.2.1.1 | | | This is the alarm trap table for MetaSwitch. A
notify is sent on this table when a MetaSwitch
object is either alarmed or cleared. Logs associated
with the alarmed object are supplied in the
Description, Cause, Effect and Action fields. If
no log is found then these fields are not filled in.
The EMSUniqueIdentifier and Alarm OID together
provide a unique identifier across all MetaViews. |
| STR alarmTrapElementName | 1.3.6.1.4.1.19444.6.2.1.1.2 | DisplayString | read-write | The internal OML name of the alarmed element |
| U32 alarmTrapElementInstance | 1.3.6.1.4.1.19444.6.2.1.1.3 | Unsigned32 | read-write | The instance of the alarmed element |
| STR alarmTrapElementDisplayType | 1.3.6.1.4.1.19444.6.2.1.1.4 | DisplayString | read-write | The display type of alarmed element |
| INT alarmTrapElementType | 1.3.6.1.4.1.19444.6.2.1.1.5 | INTEGER | read-write | The type of alarmed element |
| STR alarmTrapDisplayName | 1.3.6.1.4.1.19444.6.2.1.1.6 | DisplayString | read-write | The user-friendly display name of the alarmed element |
| STR alarmTrapDisplayPath | 1.3.6.1.4.1.19444.6.2.1.1.7 | DisplayString | read-write | The user-friendly display name of the alarmed element,
including ancestors |
| STR alarmTrapGroupDisplay | 1.3.6.1.4.1.19444.6.2.1.1.8 | DisplayString | read-write | The display name of the group
containing the alarmed element |
| INT alarmTrapGroup | 1.3.6.1.4.1.19444.6.2.1.1.9 | INTEGER | read-write | The group containing the alarmed element |
| OID alarmTrapAlarmOID | 1.3.6.1.4.1.19444.6.2.1.1.10 | OBJECT IDENTIFIER | read-write | The OID of the alarm. In this release this
is purely for deduplification. Queries on this the
Alarm MIB are not supported. |
| OID alarmTrapAlarmedObjectPrimaryOID | 1.3.6.1.4.1.19444.6.2.1.1.11 | OBJECT IDENTIFIER | read-write | The OID of the alarmed obect. Gets and Sets on
this OID are supported. |
| U32 alarmTrapSeverity | 1.3.6.1.4.1.19444.6.2.1.1.20 | Unsigned32 | read-write | Severity of the alarm condition.
0 Unknown
1-19 Diagnostics
20-29 Verbose statistics
30-39 Verbose operational
40-49 Statistics
50-59 Audit
60-69 Operational
70-79 Unexpected
80-89 Error
90-100 Fatal |
| INT alarmTrapAlarmType | 1.3.6.1.4.1.19444.6.2.1.1.21 | INTEGER | read-write | Type of the alarm. AttentionRequired implies the element
itself required attention, AttendToDependent implies
an element on which this element relies is
AttentionRequired. |
| STR alarmTrapDescription | 1.3.6.1.4.1.19444.6.2.1.1.23 | DisplayString | read-write | Detailed description of the alarmed condition. |
| STR alarmTrapCause | 1.3.6.1.4.1.19444.6.2.1.1.24 | DisplayString | read-write | Information on possible causes of the alarmed condition. |
| STR alarmTrapEffect | 1.3.6.1.4.1.19444.6.2.1.1.25 | DisplayString | read-write | Information on other events that may occur as a
result of the alarmed condition. |
| STR alarmTrapAction | 1.3.6.1.4.1.19444.6.2.1.1.26 | DisplayString | read-write | Suggested actions that you can take to resolve the problem. |
| STR alarmTrapAssociatedProblemDescription | 1.3.6.1.4.1.19444.6.2.1.1.27 | DisplayString | read-write | Description of an associated problem. |
| C64 alarmTrapLogCorrelator | 1.3.6.1.4.1.19444.6.2.1.1.28 | Counter64 | read-only | The correlator of the main log of the alarm. |
| I32 alarmTrapLogID | 1.3.6.1.4.1.19444.6.2.1.1.29 | Integer32 | read-write | Identifier for the main log of the alarm |
| STR alarmTrapEMSIdentifier | 1.3.6.1.4.1.19444.6.2.1.1.50 | DisplayString | read-write | The unique identifier of the MetaView Server. |
| STR alarmTrapEMSName | 1.3.6.1.4.1.19444.6.2.1.1.51 | DisplayString | read-write | The name of the MetaView Server. |
| STR alarmTrapEMSIPAddress | 1.3.6.1.4.1.19444.6.2.1.1.52 | DisplayString | read-write | The IP address of the MetaView Server. |
| INT alarmTrapEquipmentType | 1.3.6.1.4.1.19444.6.2.1.1.53 | INTEGER | read-write | The type of the equipment on which the alarmed condition
has been identified. |
| STR alarmTrapEquipmentIdentifier | 1.3.6.1.4.1.19444.6.2.1.1.54 | DisplayString | read-write | The unique identifier of the NE or MetaView Server. |
| STR alarmTrapEquipmentName | 1.3.6.1.4.1.19444.6.2.1.1.55 | DisplayString | read-write | The name of the equipment. This will be the
NE or MetaView Server name. |
| STR alarmTrapEquipmentIPAddress | 1.3.6.1.4.1.19444.6.2.1.1.56 | DisplayString | read-write | The IP address of the equipment. This will be the
NE or MetaView Server IP address. |
| U32 alarmTrapEquipmentSoftwareVersion | 1.3.6.1.4.1.19444.6.2.1.1.57 | Unsigned32 | read-write | The version of the software on the equipment.
For example 0x03091400 for 3.9.20. |
| STR alarmTrapEquipmentSoftwareVersionDisplay | 1.3.6.1.4.1.19444.6.2.1.1.58 | DisplayString | read-write | The displayable form of the version. |
| STR alarmTrapObjectAdditionalInformation | 1.3.6.1.4.1.19444.6.2.1.1.80 | DisplayString | read-write | User comment relating to the alarmed element. |
| STR alarmTrapObjectLocation | 1.3.6.1.4.1.19444.6.2.1.1.81 | DisplayString | read-write | The physical location of the alarmed element. |
| I32 alarmTrapAlarmCount | 1.3.6.1.4.1.19444.6.2.1.1.82 | Integer32 | read-write | Number of times this element has been alarmed |
| U32 alarmTrapCountResetTimestamp | 1.3.6.1.4.1.19444.6.2.1.1.83 | Unsigned32 | read-write | Time the alarm count on this element was last reset
in seconds since Jan 1 1970. |
| U32 alarmTrapAlarmTimestamp | 1.3.6.1.4.1.19444.6.2.1.1.84 | Unsigned32 | read-write | Time of the last alarm in seconds since Jan 1 1970. |
| I32 alarmTrapAlarmFaultType | 1.3.6.1.4.1.19444.6.2.1.1.90 | Integer32 | read-write | Whether this fault represents a (stateful) alarm or an event. |
| NTF alarmShortTrap | 1.3.6.1.4.1.19444.6.2.1.2 | | | This is a short alarm trap table for MetaSwitch.
This behaves similarly to the alarmTrap MIB, but
contains fewer fields. This should be used when
your network or alarm monitoring application requires
alarm notifcations that are not fragmented. Sending
this trap type is configured through the MetaView
Explorer on the SNMP Alarm Destination object. |
| INT alarmShortTrapElementType | 1.3.6.1.4.1.19444.6.2.1.2.5 | INTEGER | read-write | The type of alarmed element |
| STR alarmShortTrapDisplayName | 1.3.6.1.4.1.19444.6.2.1.2.6 | DisplayString | read-write | The user-friendly display name of the alarmed element |
| INT alarmShortTrapGroup | 1.3.6.1.4.1.19444.6.2.1.2.9 | INTEGER | read-write | The group containing the alarmed element |
| OID alarmShortTrapAlarmedObjectPrimaryOID | 1.3.6.1.4.1.19444.6.2.1.2.11 | OBJECT IDENTIFIER | read-write | The OID of the alarmed obect. Gets and Sets on
this OID are supported. |
| U32 alarmShortTrapSeverity | 1.3.6.1.4.1.19444.6.2.1.2.20 | Unsigned32 | read-write | Severity of the alarm condition.
0 Unknown
1-19 Diagnostics
20-29 Verbose statistics
30-39 Verbose operational
40-49 Statistics
50-59 Audit
60-69 Operational
70-79 Unexpected
80-89 Error
90-100 Fatal |
| INT alarmShortTrapAlarmType | 1.3.6.1.4.1.19444.6.2.1.2.21 | INTEGER | read-write | Type of the alarm. AttentionRequired implies the element
itself required attention, AttendToDependent implies
an element on which this element relies is
AttentionRequired. |
| STR alarmShortTrapDescription | 1.3.6.1.4.1.19444.6.2.1.2.23 | DisplayString | read-write | Detailed description of the alarmed condition. |
| STR alarmShortTrapAssociatedProblemDescription | 1.3.6.1.4.1.19444.6.2.1.2.27 | DisplayString | read-write | Description of an associated problem. |
| C64 alarmShortTrapLogCorrelator | 1.3.6.1.4.1.19444.6.2.1.2.28 | Counter64 | read-only | The correlator of the main log of the alarm. |
| I32 alarmShortTrapLogID | 1.3.6.1.4.1.19444.6.2.1.2.29 | Integer32 | read-write | Identifier for the main log of the alarm |
| STR alarmShortTrapEMSName | 1.3.6.1.4.1.19444.6.2.1.2.51 | DisplayString | read-write | The name of the MetaView Server. |
| INT alarmShortTrapEquipmentType | 1.3.6.1.4.1.19444.6.2.1.2.53 | INTEGER | read-write | The type of the equipment on which the alarmed condition
has been identified. |
| STR alarmShortTrapEquipmentName | 1.3.6.1.4.1.19444.6.2.1.2.55 | DisplayString | read-write | The name of the equipment. This will be the NE or MetaView Server name. |
| U32 alarmShortTrapEquipmentSoftwareVersion | 1.3.6.1.4.1.19444.6.2.1.2.57 | Unsigned32 | read-write | The version of the software on the equipment. |
| I32 alarmShortTrapAlarmCount | 1.3.6.1.4.1.19444.6.2.1.2.82 | Integer32 | read-write | Number of times this element has been alarmed |
| U32 alarmShortTrapCountResetTimestamp | 1.3.6.1.4.1.19444.6.2.1.2.83 | Unsigned32 | read-write | Time the alarm count on this element was last reset
in seconds since Jan 1 1970. |
| U32 alarmShortTrapAlarmTimestamp | 1.3.6.1.4.1.19444.6.2.1.2.84 | Unsigned32 | read-write | Time of the last alarm in seconds since Jan 1 1970. |
| STR alarmShortTrapAlarmIndex | 1.3.6.1.4.1.19444.6.2.1.2.85 | DisplayString | read-write | A short index for the alarm. This field is typically set to
the dot and decimal representation of the Alarm OID.
However, whent the length of the Display Name field and the
decimal OID exceeds 254 characters, a hash of the OID is used
to try and achieve a unique index. |