ME1200-ERPS-MIB :: me1200ErpsConfigRowEditorPort0SignalFailMepIndex

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › ME1200-ERPS-MIB › me1200ErpsConfigRowEditorPort0SignalFailMepIndex

me1200ErpsConfigRowEditorPort0SignalFailMepIndex

Module: ME1200-ERPS-MIB

OID (symbolic): ME1200-ERPS-MIB::me1200ErpsConfigRowEditorPort0SignalFailMepIndex

OID (numeric): 1.3.6.1.4.1.9.9.815.1.72.1.2.2.7

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: Index of SignalFail MEP for Port 0. Zero if not set. To clear an ERPS group's MEP association, set this to zero; it affects all MEP indices.

What is me1200ErpsConfigRowEditorPort0SignalFailMepIndex?

This read-write staging field in the row editor mirrors me1200ErpsConfigPort0SignalFailMepIndex, setting the Signal Fail MEP index for port 0 on the staged ring group; zero clears the group's MEP association across all MEP indices. An admin sets this while staging a ring's CFM-based failure detection before committing the row.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.815.1.72.1.2.2.7
snmpwalk -v2c -c public <target> ME1200-ERPS-MIB::me1200ErpsConfigRowEditorPort0SignalFailMepIndex

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.815.1.72.1.2.2.7.1
snmpget -v2c -c public <target> ME1200-ERPS-MIB::me1200ErpsConfigRowEditorPort0SignalFailMepIndex.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9.9.815.1.72.1.2.2.7.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> me1200ErpsConfigRowEditorPort0SignalFailMepIndex.1

Start monitoring Cisco ME1200 Metro Ethernet switch (G.8032 ring protection switching) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ME1200-ERPS-MIB::me1200ErpsConfigRowEditorPort0SignalFailMepIndex OID value, configure state conditions and alerts, and monitor any Cisco ME1200 Metro Ethernet switch (G.8032 ring protection switching) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.815ciscoME1200MIBCISCOME1200-MIB
1.3.6.1.4.1.9.9.815.1me1200SwitchMgmtCISCOME1200-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.815.1.72me1200ErpsMibME1200-ERPS-MIB
1.3.6.1.4.1.9.9.815.1.72.1me1200ErpsMIBObjectsME1200-ERPS-MIB
1.3.6.1.4.1.9.9.815.1.72.1.2me1200ErpsConfigME1200-ERPS-MIB
1.3.6.1.4.1.9.9.815.1.72.1.2.2me1200ErpsConfigRowEditorME1200-ERPS-MIB
1.3.6.1.4.1.9.9.815.1.72.1.2.2.7me1200ErpsConfigRowEditorPort0SignalFailMepIndexME1200-ERPS-MIB