MDS-SYSTEM-MIB :: mSysTemperature

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MDS-SYSTEM-MIB › mSysTemperature

mSysTemperature

Module: MDS-SYSTEM-MIB

OID (symbolic): MDS-SYSTEM-MIB::mSysTemperature

OID (numeric): 1.3.6.1.4.1.4130.10.1.1.1.2.6

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: System temperature (in Celsius).

What is mSysTemperature?

This reports the device's internal system temperature in degrees Celsius. Admins monitor this to catch overheating conditions before they cause instability, especially on outdoor-mounted MDS radios exposed to environmental extremes. A reading climbing past 70 degrees Celsius would prompt an operator to check for blocked ventilation or excessive direct sunlight on the enclosure.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4130.10.1.1.1.2.6
snmpwalk -v2c -c public <target> MDS-SYSTEM-MIB::mSysTemperature

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4130.10.1.1.1.2.6.1
snmpget -v2c -c public <target> MDS-SYSTEM-MIB::mSysTemperature.1

Start monitoring GE MDS Orbit-series industrial radio/gateway (system/hardware health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MDS-SYSTEM-MIB::mSysTemperature OID value, configure state conditions and alerts, and monitor any GE MDS Orbit-series industrial radio/gateway (system/hardware health) from a single console.

How to Use in IPNetwork Monitor

Select a GE MDS Orbit-series industrial radio/gateway (system/hardware health) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type mSysTemperature into the Find box to locate it in the OID tree, then select it and click OK. It reports the system temperature (in Celsius). On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the reported value exceeds the level expected for healthy operation, since sustained high temperature often precedes thermal shutdown or hardware degradation. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4130mdsRootMDS-REG-MIB
1.3.6.1.4.1.4130.10mdsOrbitMDS-ORBIT-SMI-MIB
1.3.6.1.4.1.4130.10.1mdsSystemMDS-ORBIT-SMI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4130.10.1.1mdsSystemMIBMDS-SYSTEM-MIB
1.3.6.1.4.1.4130.10.1.1.1mSysMIBObjectsMDS-SYSTEM-MIB
1.3.6.1.4.1.4130.10.1.1.1.2mSysStatusMDS-SYSTEM-MIB
1.3.6.1.4.1.4130.10.1.1.1.2.6mSysTemperatureMDS-SYSTEM-MIB