MDS-IF-LW-MIB :: mIfLwTemperature

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsMDS-IF-LW-MIBmIfLwTemperature

mIfLwTemperature

Module: MDS-IF-LW-MIB

OID (symbolic): MDS-IF-LW-MIB::mIfLwTemperature

OID (numeric): 1.3.6.1.4.1.4130.10.2.6.1.2.1.1.9

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The transceiver temperature.

What is mIfLwTemperature?

This read-only value reports the radio transceiver's current temperature. Admins monitor this alongside the mIfLwAlarms temperature bit to catch a unit running hot before it triggers a thermal fault.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4130.10.2.6.1.2.1.1.9
snmpwalk -v2c -c public <target> MDS-IF-LW-MIB::mIfLwTemperature

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4130.10.2.6.1.2.1.1.9.1
snmpget -v2c -c public <target> MDS-IF-LW-MIB::mIfLwTemperature.1

Start monitoring GE MDS licensed wideband radio (SCADA/telemetry) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MDS-IF-LW-MIB::mIfLwTemperature OID value, configure state conditions and alerts, and monitor any GE MDS licensed wideband radio (SCADA/telemetry) from a single console.

How to Use in IPNetwork Monitor

Select a GE MDS licensed wideband radio (SCADA/telemetry) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type mIfLwTemperature into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The transceiver temperature. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the reported value exceeds the level expected for healthy operation, since sustained high temperature often precedes thermal shutdown or hardware degradation. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4130mdsRootMDS-REG-MIB
1.3.6.1.4.1.4130.10mdsOrbitMDS-ORBIT-SMI-MIB
1.3.6.1.4.1.4130.10.2mdsInterfacesMDS-ORBIT-SMI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4130.10.2.6mdsIfLwMIBMDS-IF-LW-MIB
1.3.6.1.4.1.4130.10.2.6.1mIfLwMIBObjectsMDS-IF-LW-MIB
1.3.6.1.4.1.4130.10.2.6.1.2mIfLwStatusMDS-IF-LW-MIB
1.3.6.1.4.1.4130.10.2.6.1.2.1mIfLwStatusTableMDS-IF-LW-MIB
1.3.6.1.4.1.4130.10.2.6.1.2.1.1mIfLwStatusEntryMDS-IF-LW-MIB
1.3.6.1.4.1.4130.10.2.6.1.2.1.1.9mIfLwTemperatureMDS-IF-LW-MIB