MBG-SNMP-LT-MIB :: mbgLtFdmPlFreq

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MBG-SNMP-LT-MIB › mbgLtFdmPlFreq

mbgLtFdmPlFreq

Module: MBG-SNMP-LT-MIB

OID (symbolic): MBG-SNMP-LT-MIB::mbgLtFdmPlFreq

OID (numeric): 1.3.6.1.4.1.5597.3.11.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: shows the current powerline frequency in mHz as an Integer32 value

What is mbgLtFdmPlFreq?

Current powerline frequency in millihertz as an integer; for example 50012 means 50.012 Hz. It comes from the frequency deviation monitoring feature.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5597.3.11.1
snmpwalk -v2c -c public <target> MBG-SNMP-LT-MIB::mbgLtFdmPlFreq

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5597.3.11.1.1
snmpget -v2c -c public <target> MBG-SNMP-LT-MIB::mbgLtFdmPlFreq.1

Start monitoring Meinberg LanTime network time server with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MBG-SNMP-LT-MIB::mbgLtFdmPlFreq OID value, configure state conditions and alerts, and monitor any Meinberg LanTime network time server from a single console.