MBG-SNMP-LT-MIB :: mbgLtCfgSHSWarnLimit

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › MBG-SNMP-LT-MIB › mbgLtCfgSHSWarnLimit

mbgLtCfgSHSWarnLimit

Module: MBG-SNMP-LT-MIB

OID (symbolic): MBG-SNMP-LT-MIB::mbgLtCfgSHSWarnLimit

OID (numeric): 1.3.6.1.4.1.5597.3.4.9.2

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: Max. number of milliseconds the two SHS references can differ before a SHS Warning Timelimit error is issued

What is mbgLtCfgSHSWarnLimit?

Maximum milliseconds the two SHS time references may differ before a warning time-limit error is raised. Set it below the critical limit to get an early warning.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5597.3.4.9.2
snmpwalk -v2c -c public <target> MBG-SNMP-LT-MIB::mbgLtCfgSHSWarnLimit

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5597.3.4.9.2.1
snmpget -v2c -c public <target> MBG-SNMP-LT-MIB::mbgLtCfgSHSWarnLimit.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5597.3.4.9.2.1 i <value>

Start monitoring Meinberg LanTime network time server with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MBG-SNMP-LT-MIB::mbgLtCfgSHSWarnLimit OID value, configure state conditions and alerts, and monitor any Meinberg LanTime network time server from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5597mbgSnmpRootMBG-SNMP-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5597.3mbgLantimeMBG-SNMP-LT-MIB
1.3.6.1.4.1.5597.3.4mbgLtCfgMBG-SNMP-LT-MIB
1.3.6.1.4.1.5597.3.4.9mbgLtCfgSHSMBG-SNMP-LT-MIB
1.3.6.1.4.1.5597.3.4.9.2mbgLtCfgSHSWarnLimitMBG-SNMP-LT-MIB