LSIRAID-IDE-MIB :: contFastInit

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › LSIRAID-IDE-MIB › contFastInit

contFastInit

Module: LSIRAID-IDE-MIB

OID (symbolic): LSIRAID-IDE-MIB::contFastInit

OID (numeric): 1.3.6.1.4.1.674.3.2.1.2.1.15

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: How initialization will performed FAST/Complete.

What is contFastInit?

This selects whether new logical drives are initialized with a fast, enable(1), pass or a full, disable(2), pass that zeroes the entire drive. An admin needing a volume ready immediately picks fast init, accepting that a full init is more thorough for data-wipe purposes.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.3.2.1.2.1.15
snmpwalk -v2c -c public <target> LSIRAID-IDE-MIB::contFastInit

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.674.3.2.1.2.1.15.1
snmpget -v2c -c public <target> LSIRAID-IDE-MIB::contFastInit.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.674.3.2.1.2.1.15.1 i <value>

Start monitoring LSI RAID controllers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LSIRAID-IDE-MIB::contFastInit OID value, configure state conditions and alerts, and monitor any LSI RAID controllers from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.674dellArrayManager-MIB
Numeric OIDNameModule
1.3.6.1.4.1.674.3megaIDELSIRAID-IDE-MIB
1.3.6.1.4.1.674.3.2ideLSIRAID-IDE-MIB
1.3.6.1.4.1.674.3.2.1ideControllersLSIRAID-IDE-MIB
1.3.6.1.4.1.674.3.2.1.2contTableLSIRAID-IDE-MIB
1.3.6.1.4.1.674.3.2.1.2.1contEntryLSIRAID-IDE-MIB
1.3.6.1.4.1.674.3.2.1.2.1.15contFastInitLSIRAID-IDE-MIB